Question 590
At a large enterprise updating redundant switch links, a Junos specialist investigates this scenario: Two parallel switch uplinks form a Layer 2 loop because they were attached without a compatible aggregation design. The change must retain both link resilience and correct VLAN isolation. Which response best restores the intended behavior?
Explanation
Correct Answer
For a large enterprise updating redundant switch links, the direct corrective action is: Configure supported LACP or static aggregated Ethernet on both ends as appropriate. This addresses the mechanism: A link aggregation group presents multiple member links as one logical Ethernet interface when both peers agree. Confirm by checking: The aggregate reports active members and traffic survives loss of one constituent link. During rollout, check LACP mode, member speed and VLAN consistency before bringing up the bundle.
Incorrect Answers
A provider S-VLAN or equivalent encapsulation boundary is needed to keep identical customer C-VLAN numbers separate. The appropriate correction for the reported case is: Configure supported LACP or static aggregated Ethernet on both ends as appropriate.
Layer 2 switches learn source MAC addresses on ingress ports and forward known unicast using their MAC tables. Fixing that different mechanism would not address the current root cause: a link aggregation group presents multiple member links as one logical Ethernet interface when both peers agree.
VLAN Spanning Tree Protocol allows separate tree instances for selected VLANs and can choose different roots. Its verification is distinct from the reported condition: Two parallel switch uplinks form a Layer 2 loop because they were attached without a compatible aggregation design. The change must retain both link resilience and correct VLAN isolation.