mcAfee Secure Website
exam =5
exam =6

Exam Code: NS0-165

Exam Name: NetApp Certified Data Administrator, ONTAP

Certification Provider: Network Appliance

Corresponding Certification: NCDA ONTAP

Network Appliance NS0-165 Questions & Answers

Reliable & Actual Study Materials for NS0-165 Exam Success

60 Questions & Answers with Testing Engine

"NS0-165: NetApp Certified Data Administrator, ONTAP" Testing Engine covers all the knowledge points of the real Network Appliance NS0-165 exam.

The latest actual NS0-165 Questions & Answers from Pass4sure. Everything you need to prepare and get best score at NS0-165 exam easily and quickly.

exam =7
Guarantee

Satisfaction Guaranteed

Pass4sure has a remarkable Network Appliance Candidate Success record. We're confident of our products and provide no hassle product exchange. That's how confident we are!

99.3% Pass Rate
Was: $137.49
Now: $124.99

Network Appliance NS0-165 Practice Test 45

Question 440

A NetApp ONTAP administrator must resolve this situation: A planned block shrink is attempted without checking filesystem safety. Which TWO choices form a defensible remediation-and-acceptance pair? (Select TWO.)

  1. Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data.
  2. Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails.
  3. A controlled path failure leaves the host device online and its multipath utility shows expected surviving paths.
  4. Coordinate ONTAP LUN or namespace capacity changes with host rescan and filesystem growth procedures.
  5. The host detects the intended expanded block device and its filesystem grows without altering unrelated disks.

Explanation

Correct Answers

D:

This is the proposed corrective action for: A planned block shrink is attempted without checking filesystem safety. The action addresses the ONTAP failure mechanism: A volume resize alone does not guarantee that the operating system or application sees additional block space.

E:

This provides separate verification for the same issue: A planned block shrink is attempted without checking filesystem safety. The outcome tests whether remediation is effective and can be recorded as acceptance evidence.

Incorrect Answers

A:

Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data. The paired controls concern san device size and rescan coordination, not that measure.

B:

Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails. The san device size and rescan coordination implementation and safeguard are still missing.

C:

A controlled path failure leaves the host device online and its multipath utility shows expected surviving paths. It is not the complementary risk control for san device size and rescan coordination.

Question 441

During a storage operations review for a regional managed storage service provider, the team observes: An iSCSI session fails after the CHAP secret is rotated on one side only. The decision must maintain tenant boundaries and documented service commitments. Which ONTAP administration change best addresses the observed failure?

  1. Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails.
  2. Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data.
  3. Coordinate ONTAP LUN or namespace capacity changes with host rescan and filesystem growth procedures.
  4. Configure supported host multipath software and ONTAP SAN paths so failover remains possible and optimized or nonoptimized path states are handled appropriately.

Explanation

Correct Answer

A:

This action addresses the reported ONTAP condition: An iSCSI session fails after the CHAP secret is rotated on one side only. It specifically applies iscsi authentication and network loss triage and mitigates: Blindly recreating a LUN cannot fix an unreachable portal or mismatched authentication credentials. A practical completion check is: The initiator logs into the correct target over an allowed network and receives the expected mapped device.

Incorrect Answers

B:

Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data. It changes a different feature than iscsi authentication and network loss triage.

C:

Coordinate ONTAP LUN or namespace capacity changes with host rescan and filesystem growth procedures. That change would not implement iscsi authentication and network loss triage.

D:

Configure supported host multipath software and ONTAP SAN paths so failover remains possible and optimized or nonoptimized path states are handled appropriately. The configuration must instead establish iscsi authentication and network loss triage.

Question 442

After corrective work for the ONTAP issue 'An iSCSI session fails after the CHAP secret is rotated on one side only', the operator seeks objective signoff. Which acceptance result demonstrates that this ONTAP issue has been corrected?

  1. Corrected FC zoning or port state restores expected target visibility and multipathing without touching data blocks.
  2. The host detects the intended expanded block device and its filesystem grows without altering unrelated disks.
  3. The initiator logs into the correct target over an allowed network and receives the expected mapped device.
  4. A controlled path failure leaves the host device online and its multipath utility shows expected surviving paths.

Explanation

Correct Answer

C:

This is observable acceptance evidence for: An iSCSI session fails after the CHAP secret is rotated on one side only. It demonstrates the intended ONTAP storage behavior in the relevant situation, rather than merely showing that a configuration field exists.

Incorrect Answers

A:

Corrected FC zoning or port state restores expected target visibility and multipathing without touching data blocks. The relevant success criterion is iscsi authentication and network loss triage; this measures a different function.

B:

The host detects the intended expanded block device and its filesystem grows without altering unrelated disks. That result could pass without demonstrating iscsi authentication and network loss triage.

D:

A controlled path failure leaves the host device online and its multipath utility shows expected surviving paths. It does not establish the requested iscsi authentication and network loss triage outcome.

Question 443

During a storage operations review for an enterprise disaster recovery review, the team observes: A new initiator IP cannot route to the storage target network. The decision must maintain preservation of recoverable data under controlled change. What should the storage administrator do first for the stated requirement?

  1. Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails.
  2. Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data.
  3. Configure supported host multipath software and ONTAP SAN paths so failover remains possible and optimized or nonoptimized path states are handled appropriately.
  4. Coordinate ONTAP LUN or namespace capacity changes with host rescan and filesystem growth procedures.

Explanation

Correct Answer

A:

This action addresses the reported ONTAP condition: A new initiator IP cannot route to the storage target network. It specifically applies iscsi authentication and network loss triage and mitigates: Blindly recreating a LUN cannot fix an unreachable portal or mismatched authentication credentials. A practical completion check is: The initiator logs into the correct target over an allowed network and receives the expected mapped device.

Incorrect Answers

B:

Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data. The configuration must instead establish iscsi authentication and network loss triage.

C:

Configure supported host multipath software and ONTAP SAN paths so failover remains possible and optimized or nonoptimized path states are handled appropriately. The iscsi authentication and network loss triage prerequisite remains unaddressed.

D:

Coordinate ONTAP LUN or namespace capacity changes with host rescan and filesystem growth procedures. It changes a different feature than iscsi authentication and network loss triage.

Question 444

After corrective work for the ONTAP issue 'A new initiator IP cannot route to the storage target network', the operator seeks objective signoff. What observable test should the operator require before closing this issue?

  1. The initiator logs into the correct target over an allowed network and receives the expected mapped device.
  2. Corrected FC zoning or port state restores expected target visibility and multipathing without touching data blocks.
  3. A controlled path failure leaves the host device online and its multipath utility shows expected surviving paths.
  4. The host detects the intended expanded block device and its filesystem grows without altering unrelated disks.

Explanation

Correct Answer

A:

This is observable acceptance evidence for: A new initiator IP cannot route to the storage target network. It demonstrates the intended ONTAP storage behavior in the relevant situation, rather than merely showing that a configuration field exists.

Incorrect Answers

B:

Corrected FC zoning or port state restores expected target visibility and multipathing without touching data blocks. The iscsi authentication and network loss triage prerequisite remains unaddressed.

C:

A controlled path failure leaves the host device online and its multipath utility shows expected surviving paths. It changes a different feature than iscsi authentication and network loss triage.

D:

The host detects the intended expanded block device and its filesystem grows without altering unrelated disks. That change would not implement iscsi authentication and network loss triage.

Question 445

During a storage operations review for a regulated healthcare records provider, the team observes: An initiator IQN differs from the value authorized by the igroup. The decision must maintain patient data and application recovery obligations. Which engineering choice most directly solves this problem?

  1. Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data.
  2. Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails.
  3. Configure supported host multipath software and ONTAP SAN paths so failover remains possible and optimized or nonoptimized path states are handled appropriately.
  4. Coordinate ONTAP LUN or namespace capacity changes with host rescan and filesystem growth procedures.

Explanation

Correct Answer

B:

This action addresses the reported ONTAP condition: An initiator IQN differs from the value authorized by the igroup. It specifically applies iscsi authentication and network loss triage and mitigates: Blindly recreating a LUN cannot fix an unreachable portal or mismatched authentication credentials. A practical completion check is: The initiator logs into the correct target over an allowed network and receives the expected mapped device.

Incorrect Answers

A:

Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data. The iscsi authentication and network loss triage prerequisite remains unaddressed.

C:

Configure supported host multipath software and ONTAP SAN paths so failover remains possible and optimized or nonoptimized path states are handled appropriately. That change would not implement iscsi authentication and network loss triage.

D:

Coordinate ONTAP LUN or namespace capacity changes with host rescan and filesystem growth procedures. The configuration must instead establish iscsi authentication and network loss triage.

Question 446

After corrective work for the ONTAP issue 'An initiator IQN differs from the value authorized by the igroup', the operator seeks objective signoff. Which verification is most relevant to the storage problem described?

  1. The initiator logs into the correct target over an allowed network and receives the expected mapped device.
  2. Corrected FC zoning or port state restores expected target visibility and multipathing without touching data blocks.
  3. A controlled path failure leaves the host device online and its multipath utility shows expected surviving paths.
  4. The host detects the intended expanded block device and its filesystem grows without altering unrelated disks.

Explanation

Correct Answer

A:

This is observable acceptance evidence for: An initiator IQN differs from the value authorized by the igroup. It demonstrates the intended ONTAP storage behavior in the relevant situation, rather than merely showing that a configuration field exists.

Incorrect Answers

B:

Corrected FC zoning or port state restores expected target visibility and multipathing without touching data blocks. That result could pass without demonstrating iscsi authentication and network loss triage.

C:

A controlled path failure leaves the host device online and its multipath utility shows expected surviving paths. Acceptance here depends on observing iscsi authentication and network loss triage, not only that test.

D:

The host detects the intended expanded block device and its filesystem grows without altering unrelated disks. It does not establish the requested iscsi authentication and network loss triage outcome.

Question 447

During a storage operations review for a university research storage team, the team observes: An application operator assumes a missing LUN means the containing aggregate is offline. The decision must maintain shared-client safety and reproducible workloads. Which change best corrects the storage design under these conditions?

  1. Coordinate ONTAP LUN or namespace capacity changes with host rescan and filesystem growth procedures.
  2. Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data.
  3. Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails.
  4. Configure supported host multipath software and ONTAP SAN paths so failover remains possible and optimized or nonoptimized path states are handled appropriately.

Explanation

Correct Answer

C:

This action addresses the reported ONTAP condition: An application operator assumes a missing LUN means the containing aggregate is offline. It specifically applies iscsi authentication and network loss triage and mitigates: Blindly recreating a LUN cannot fix an unreachable portal or mismatched authentication credentials. A practical completion check is: The initiator logs into the correct target over an allowed network and receives the expected mapped device.

Incorrect Answers

A:

Coordinate ONTAP LUN or namespace capacity changes with host rescan and filesystem growth procedures. That change would not implement iscsi authentication and network loss triage.

B:

Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data. The configuration must instead establish iscsi authentication and network loss triage.

D:

Configure supported host multipath software and ONTAP SAN paths so failover remains possible and optimized or nonoptimized path states are handled appropriately. It changes a different feature than iscsi authentication and network loss triage.

Question 448

A NetApp ONTAP change review identifies: An application operator assumes a missing LUN means the containing aggregate is offline. What failure mode explains the need for corrective action?

  1. A fabric path failure can look like inaccessible storage while the ONTAP LUN and volume remain healthy.
  2. Blindly recreating a LUN cannot fix an unreachable portal or mismatched authentication credentials.
  3. A volume resize alone does not guarantee that the operating system or application sees additional block space.
  4. A single path or incorrect MPIO configuration can cause application outages despite a healthy storage HA pair.

Explanation

Correct Answer

B:

This is the directly implicated exposure when an application operator assumes a missing LUN means the containing aggregate is offline. The relevant corrective control is: Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails. A meaningful acceptance test is: The initiator logs into the correct target over an allowed network and receives the expected mapped device.

Incorrect Answers

A:

A fabric path failure can look like inaccessible storage while the ONTAP LUN and volume remain healthy. The configuration must instead establish iscsi authentication and network loss triage.

C:

A volume resize alone does not guarantee that the operating system or application sees additional block space. It changes a different feature than iscsi authentication and network loss triage.

D:

A single path or incorrect MPIO configuration can cause application outages despite a healthy storage HA pair. That change would not implement iscsi authentication and network loss triage.

Question 449

During a storage operations review for a regulated healthcare records provider, the team observes: One FC fabric disappears after a switch firmware change. The decision must maintain patient data and application recovery obligations. Which ONTAP administration change best addresses the observed failure?

  1. Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data.
  2. Configure supported host multipath software and ONTAP SAN paths so failover remains possible and optimized or nonoptimized path states are handled appropriately.
  3. Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails.
  4. Coordinate ONTAP LUN or namespace capacity changes with host rescan and filesystem growth procedures.

Explanation

Correct Answer

A:

This action addresses the reported ONTAP condition: One FC fabric disappears after a switch firmware change. It specifically applies fc fabric path and zoning troubleshooting and mitigates: A fabric path failure can look like inaccessible storage while the ONTAP LUN and volume remain healthy. A practical completion check is: Corrected FC zoning or port state restores expected target visibility and multipathing without touching data blocks.

Incorrect Answers

B:

Configure supported host multipath software and ONTAP SAN paths so failover remains possible and optimized or nonoptimized path states are handled appropriately. It changes a different feature than fc fabric path and zoning troubleshooting.

C:

Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails. That change would not implement fc fabric path and zoning troubleshooting.

D:

Coordinate ONTAP LUN or namespace capacity changes with host rescan and filesystem growth procedures. The configuration must instead establish fc fabric path and zoning troubleshooting.

Question 450

A NetApp ONTAP administrator must resolve this situation: One FC fabric disappears after a switch firmware change. Select TWO: the targeted corrective action and its strongest verification. (Select TWO.)

  1. Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails.
  2. A controlled path failure leaves the host device online and its multipath utility shows expected surviving paths.
  3. Coordinate ONTAP LUN or namespace capacity changes with host rescan and filesystem growth procedures.
  4. Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data.
  5. Corrected FC zoning or port state restores expected target visibility and multipathing without touching data blocks.

Explanation

Correct Answers

D:

This is the proposed corrective action for: One FC fabric disappears after a switch firmware change. The action addresses the ONTAP failure mechanism: A fabric path failure can look like inaccessible storage while the ONTAP LUN and volume remain healthy.

E:

This provides separate verification for the same issue: One FC fabric disappears after a switch firmware change. The outcome tests whether remediation is effective and can be recorded as acceptance evidence.

Incorrect Answers

A:

Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails. It is not the complementary risk control for fc fabric path and zoning troubleshooting.

B:

A controlled path failure leaves the host device online and its multipath utility shows expected surviving paths. This does not supply the required fc fabric path and zoning troubleshooting action-and-control pair.

C:

Coordinate ONTAP LUN or namespace capacity changes with host rescan and filesystem growth procedures. The paired controls concern fc fabric path and zoning troubleshooting, not that measure.

NetApp Certified Data Administrator, ONTAP (NS0-165) Practice Tests