mcAfee Secure Website
exam =5
exam =6

Exam Code: NS0-165

Exam Name: NetApp Certified Data Administrator, ONTAP

Certification Provider: Network Appliance

Corresponding Certification: NCDA ONTAP

Network Appliance NS0-165 Questions & Answers

Reliable & Actual Study Materials for NS0-165 Exam Success

60 Questions & Answers with Testing Engine

"NS0-165: NetApp Certified Data Administrator, ONTAP" Testing Engine covers all the knowledge points of the real Network Appliance NS0-165 exam.

The latest actual NS0-165 Questions & Answers from Pass4sure. Everything you need to prepare and get best score at NS0-165 exam easily and quickly.

exam =7
Guarantee

Satisfaction Guaranteed

Pass4sure has a remarkable Network Appliance Candidate Success record. We're confident of our products and provide no hassle product exchange. That's how confident we are!

99.3% Pass Rate
Was: $137.49
Now: $124.99

Network Appliance NS0-165 Practice Test 43

Question 420

A NetApp ONTAP administrator must resolve this situation: An administrator attempts to use an FC igroup as the only NVMe namespace control. Which TWO choices form a defensible remediation-and-acceptance pair? (Select TWO.)

  1. Use supported NVMe namespaces and subsystems, mapping host NQNs through NVMe/FC or NVMe/TCP rather than treating them as classic LUN igroups.
  2. The authorized host NQN discovers a mapped namespace over the intended NVMe transport and a test IO succeeds.
  3. Create ONTAP initiator groups containing permitted host IQNs or FC WWPNs and map intended LUNs using supported host operating-system types.
  4. The host discovers the intended iSCSI target and establishes a supported session on the correct storage network.
  5. Provide redundant supported FC zoning between authorized initiator WWPNs and ONTAP FC target ports before LUN mapping.

Explanation

Correct Answers

A:

This is the proposed corrective action for: An administrator attempts to use an FC igroup as the only NVMe namespace control. The action addresses the ONTAP failure mechanism: An NVMe host does not discover a namespace from an unrelated iSCSI LUN mapping or FC WWPN alone.

B:

This provides separate verification for the same issue: An administrator attempts to use an FC igroup as the only NVMe namespace control. The outcome tests whether remediation is effective and can be recorded as acceptance evidence.

Incorrect Answers

C:

Create ONTAP initiator groups containing permitted host IQNs or FC WWPNs and map intended LUNs using supported host operating-system types. It is not the complementary risk control for nvme namespace and subsystem provisioning.

D:

The host discovers the intended iSCSI target and establishes a supported session on the correct storage network. This does not supply the required nvme namespace and subsystem provisioning action-and-control pair.

E:

Provide redundant supported FC zoning between authorized initiator WWPNs and ONTAP FC target ports before LUN mapping. The two-part nvme namespace and subsystem provisioning control remains unsatisfied.

Question 421

During a storage operations review for a regional managed storage service provider, the team observes: A storage team confuses an NVMe namespace identifier with a LUN ID. The decision must maintain tenant boundaries and documented service commitments. Which engineering choice most directly solves this problem?

  1. Configure the SVM iSCSI service, data LIFs and host initiator discovery on the supported storage network before presenting LUNs.
  2. Provide redundant supported FC zoning between authorized initiator WWPNs and ONTAP FC target ports before LUN mapping.
  3. Create ONTAP initiator groups containing permitted host IQNs or FC WWPNs and map intended LUNs using supported host operating-system types.
  4. Use supported NVMe namespaces and subsystems, mapping host NQNs through NVMe/FC or NVMe/TCP rather than treating them as classic LUN igroups.

Explanation

Correct Answer

D:

This action addresses the reported ONTAP condition: A storage team confuses an NVMe namespace identifier with a LUN ID. It specifically applies nvme namespace and subsystem provisioning and mitigates: An NVMe host does not discover a namespace from an unrelated iSCSI LUN mapping or FC WWPN alone. A practical completion check is: The authorized host NQN discovers a mapped namespace over the intended NVMe transport and a test IO succeeds.

Incorrect Answers

A:

Configure the SVM iSCSI service, data LIFs and host initiator discovery on the supported storage network before presenting LUNs. The nvme namespace and subsystem provisioning prerequisite remains unaddressed.

B:

Provide redundant supported FC zoning between authorized initiator WWPNs and ONTAP FC target ports before LUN mapping. It changes a different feature than nvme namespace and subsystem provisioning.

C:

Create ONTAP initiator groups containing permitted host IQNs or FC WWPNs and map intended LUNs using supported host operating-system types. That change would not implement nvme namespace and subsystem provisioning.

Question 422

After corrective work for the ONTAP issue 'A storage team confuses an NVMe namespace identifier with a LUN ID', the operator seeks objective signoff. Which verification is most relevant to the storage problem described?

  1. The host discovers the intended iSCSI target and establishes a supported session on the correct storage network.
  2. The authorized host NQN discovers a mapped namespace over the intended NVMe transport and a test IO succeeds.
  3. Host HBA ports log in through the intended fabrics and show the correct ONTAP target WWPNs.
  4. Only authorized initiators discover the LUN and see a consistent device identity and intended host access policy.

Explanation

Correct Answer

B:

This is observable acceptance evidence for: A storage team confuses an NVMe namespace identifier with a LUN ID. It demonstrates the intended ONTAP storage behavior in the relevant situation, rather than merely showing that a configuration field exists.

Incorrect Answers

A:

The host discovers the intended iSCSI target and establishes a supported session on the correct storage network. The relevant success criterion is nvme namespace and subsystem provisioning; this measures a different function.

C:

Host HBA ports log in through the intended fabrics and show the correct ONTAP target WWPNs. Acceptance here depends on observing nvme namespace and subsystem provisioning, not only that test.

D:

Only authorized initiators discover the LUN and see a consistent device identity and intended host access policy. It does not establish the requested nvme namespace and subsystem provisioning outcome.

Question 423

During a storage operations review for an enterprise disaster recovery review, the team observes: A rollout includes NVMe-capable hosts but the ONTAP SVM lacks the needed protocol configuration. The decision must maintain preservation of recoverable data under controlled change. Which change best corrects the storage design under these conditions?

  1. Use supported NVMe namespaces and subsystems, mapping host NQNs through NVMe/FC or NVMe/TCP rather than treating them as classic LUN igroups.
  2. Provide redundant supported FC zoning between authorized initiator WWPNs and ONTAP FC target ports before LUN mapping.
  3. Create ONTAP initiator groups containing permitted host IQNs or FC WWPNs and map intended LUNs using supported host operating-system types.
  4. Configure the SVM iSCSI service, data LIFs and host initiator discovery on the supported storage network before presenting LUNs.

Explanation

Correct Answer

A:

This action addresses the reported ONTAP condition: A rollout includes NVMe-capable hosts but the ONTAP SVM lacks the needed protocol configuration. It specifically applies nvme namespace and subsystem provisioning and mitigates: An NVMe host does not discover a namespace from an unrelated iSCSI LUN mapping or FC WWPN alone. A practical completion check is: The authorized host NQN discovers a mapped namespace over the intended NVMe transport and a test IO succeeds.

Incorrect Answers

B:

Provide redundant supported FC zoning between authorized initiator WWPNs and ONTAP FC target ports before LUN mapping. The configuration must instead establish nvme namespace and subsystem provisioning.

C:

Create ONTAP initiator groups containing permitted host IQNs or FC WWPNs and map intended LUNs using supported host operating-system types. The nvme namespace and subsystem provisioning prerequisite remains unaddressed.

D:

Configure the SVM iSCSI service, data LIFs and host initiator discovery on the supported storage network before presenting LUNs. It changes a different feature than nvme namespace and subsystem provisioning.

Question 424

After corrective work for the ONTAP issue 'A rollout includes NVMe-capable hosts but the ONTAP SVM lacks the needed protocol configuration', the operator seeks objective signoff. What evidence would show that the corrective configuration is working?

  1. Host HBA ports log in through the intended fabrics and show the correct ONTAP target WWPNs.
  2. Only authorized initiators discover the LUN and see a consistent device identity and intended host access policy.
  3. The host discovers the intended iSCSI target and establishes a supported session on the correct storage network.
  4. The authorized host NQN discovers a mapped namespace over the intended NVMe transport and a test IO succeeds.

Explanation

Correct Answer

D:

This is observable acceptance evidence for: A rollout includes NVMe-capable hosts but the ONTAP SVM lacks the needed protocol configuration. It demonstrates the intended ONTAP storage behavior in the relevant situation, rather than merely showing that a configuration field exists.

Incorrect Answers

A:

Host HBA ports log in through the intended fabrics and show the correct ONTAP target WWPNs. Acceptance here depends on observing nvme namespace and subsystem provisioning, not only that test.

B:

Only authorized initiators discover the LUN and see a consistent device identity and intended host access policy. It does not establish the requested nvme namespace and subsystem provisioning outcome.

C:

The host discovers the intended iSCSI target and establishes a supported session on the correct storage network. The relevant success criterion is nvme namespace and subsystem provisioning; this measures a different function.

Question 425

During a storage operations review for a regional managed storage service provider, the team observes: A Windows host sees duplicate raw disks instead of one multipathed LUN. The decision must maintain tenant boundaries and documented service commitments. Which ONTAP administration change best addresses the observed failure?

  1. Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data.
  2. Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails.
  3. Configure supported host multipath software and ONTAP SAN paths so failover remains possible and optimized or nonoptimized path states are handled appropriately.
  4. Coordinate ONTAP LUN or namespace capacity changes with host rescan and filesystem growth procedures.

Explanation

Correct Answer

C:

This action addresses the reported ONTAP condition: A Windows host sees duplicate raw disks instead of one multipathed LUN. It specifically applies san host multipathing and alua path state and mitigates: A single path or incorrect MPIO configuration can cause application outages despite a healthy storage HA pair. A practical completion check is: A controlled path failure leaves the host device online and its multipath utility shows expected surviving paths.

Incorrect Answers

A:

Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data. The san host multipathing and alua path state prerequisite remains unaddressed.

B:

Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails. It changes a different feature than san host multipathing and alua path state.

D:

Coordinate ONTAP LUN or namespace capacity changes with host rescan and filesystem growth procedures. The configuration must instead establish san host multipathing and alua path state.

Question 426

After corrective work for the ONTAP issue 'A Windows host sees duplicate raw disks instead of one multipathed LUN', the operator seeks objective signoff. Which acceptance result demonstrates that this ONTAP issue has been corrected?

  1. The initiator logs into the correct target over an allowed network and receives the expected mapped device.
  2. A controlled path failure leaves the host device online and its multipath utility shows expected surviving paths.
  3. Corrected FC zoning or port state restores expected target visibility and multipathing without touching data blocks.
  4. The host detects the intended expanded block device and its filesystem grows without altering unrelated disks.

Explanation

Correct Answer

B:

This is observable acceptance evidence for: A Windows host sees duplicate raw disks instead of one multipathed LUN. It demonstrates the intended ONTAP storage behavior in the relevant situation, rather than merely showing that a configuration field exists.

Incorrect Answers

A:

The initiator logs into the correct target over an allowed network and receives the expected mapped device. The relevant success criterion is san host multipathing and alua path state; this measures a different function.

C:

Corrected FC zoning or port state restores expected target visibility and multipathing without touching data blocks. Acceptance here depends on observing san host multipathing and alua path state, not only that test.

D:

The host detects the intended expanded block device and its filesystem grows without altering unrelated disks. It does not establish the requested san host multipathing and alua path state outcome.

Question 427

During a storage operations review for an enterprise disaster recovery review, the team observes: An ESXi datastore disappears when one target port fails. The decision must maintain preservation of recoverable data under controlled change. What should the storage administrator do first for the stated requirement?

  1. Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data.
  2. Coordinate ONTAP LUN or namespace capacity changes with host rescan and filesystem growth procedures.
  3. Configure supported host multipath software and ONTAP SAN paths so failover remains possible and optimized or nonoptimized path states are handled appropriately.
  4. Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails.

Explanation

Correct Answer

C:

This action addresses the reported ONTAP condition: An ESXi datastore disappears when one target port fails. It specifically applies san host multipathing and alua path state and mitigates: A single path or incorrect MPIO configuration can cause application outages despite a healthy storage HA pair. A practical completion check is: A controlled path failure leaves the host device online and its multipath utility shows expected surviving paths.

Incorrect Answers

A:

Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data. That change would not implement san host multipathing and alua path state.

B:

Coordinate ONTAP LUN or namespace capacity changes with host rescan and filesystem growth procedures. The configuration must instead establish san host multipathing and alua path state.

D:

Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails. It changes a different feature than san host multipathing and alua path state.

Question 428

A NetApp ONTAP change review identifies: An ESXi datastore disappears when one target port fails. Which unresolved risk most directly follows from the observed condition?

  1. Blindly recreating a LUN cannot fix an unreachable portal or mismatched authentication credentials.
  2. A volume resize alone does not guarantee that the operating system or application sees additional block space.
  3. A fabric path failure can look like inaccessible storage while the ONTAP LUN and volume remain healthy.
  4. A single path or incorrect MPIO configuration can cause application outages despite a healthy storage HA pair.

Explanation

Correct Answer

D:

This is the directly implicated exposure when an ESXi datastore disappears when one target port fails. The relevant corrective control is: Configure supported host multipath software and ONTAP SAN paths so failover remains possible and optimized or nonoptimized path states are handled appropriately. A meaningful acceptance test is: A controlled path failure leaves the host device online and its multipath utility shows expected surviving paths.

Incorrect Answers

A:

Blindly recreating a LUN cannot fix an unreachable portal or mismatched authentication credentials. Recurrence here depends on san host multipathing and alua path state, not this safeguard.

B:

A volume resize alone does not guarantee that the operating system or application sees additional block space. That protection can exist while san host multipathing and alua path state is still missing.

C:

A fabric path failure can look like inaccessible storage while the ONTAP LUN and volume remain healthy. It protects a different risk than the san host multipathing and alua path state requirement.

Question 429

During a storage operations review for a regulated healthcare records provider, the team observes: A Linux multipath configuration uses only one iSCSI session. The decision must maintain patient data and application recovery obligations. Which engineering choice most directly solves this problem?

  1. Configure supported host multipath software and ONTAP SAN paths so failover remains possible and optimized or nonoptimized path states are handled appropriately.
  2. Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data.
  3. Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails.
  4. Coordinate ONTAP LUN or namespace capacity changes with host rescan and filesystem growth procedures.

Explanation

Correct Answer

A:

This action addresses the reported ONTAP condition: A Linux multipath configuration uses only one iSCSI session. It specifically applies san host multipathing and alua path state and mitigates: A single path or incorrect MPIO configuration can cause application outages despite a healthy storage HA pair. A practical completion check is: A controlled path failure leaves the host device online and its multipath utility shows expected surviving paths.

Incorrect Answers

B:

Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data. It changes a different feature than san host multipathing and alua path state.

C:

Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails. That change would not implement san host multipathing and alua path state.

D:

Coordinate ONTAP LUN or namespace capacity changes with host rescan and filesystem growth procedures. The configuration must instead establish san host multipathing and alua path state.

Question 430

A NetApp ONTAP administrator must resolve this situation: A Linux multipath configuration uses only one iSCSI session. Select TWO: the targeted corrective action and its strongest verification. (Select TWO.)

  1. Configure supported host multipath software and ONTAP SAN paths so failover remains possible and optimized or nonoptimized path states are handled appropriately.
  2. Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data.
  3. Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails.
  4. The host detects the intended expanded block device and its filesystem grows without altering unrelated disks.
  5. A controlled path failure leaves the host device online and its multipath utility shows expected surviving paths.

Explanation

Correct Answers

A:

This is the proposed corrective action for: A Linux multipath configuration uses only one iSCSI session. The action addresses the ONTAP failure mechanism: A single path or incorrect MPIO configuration can cause application outages despite a healthy storage HA pair.

E:

This provides separate verification for the same issue: A Linux multipath configuration uses only one iSCSI session. The outcome tests whether remediation is effective and can be recorded as acceptance evidence.

Incorrect Answers

B:

Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data. This does not supply the required san host multipathing and alua path state action-and-control pair.

C:

Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails. The paired controls concern san host multipathing and alua path state, not that measure.

D:

The host detects the intended expanded block device and its filesystem grows without altering unrelated disks. The san host multipathing and alua path state implementation and safeguard are still missing.