exam =5
exam =6

Exam Code: NS0-165

Exam Name: NetApp Certified Data Administrator, ONTAP

Certification Provider: Network Appliance

Corresponding Certification: NCDA ONTAP

Network Appliance NS0-165 Questions & Answers

Reliable & Actual Study Materials for NS0-165 Exam Success

60 Questions & Answers with Testing Engine

"NS0-165: NetApp Certified Data Administrator, ONTAP" Testing Engine covers all the knowledge points of the real Network Appliance NS0-165 exam.

The latest actual NS0-165 Questions & Answers from Pass4sure. Everything you need to prepare and get best score at NS0-165 exam easily and quickly.

exam =7
Guarantee

Satisfaction Guaranteed

Pass4sure has a remarkable Network Appliance Candidate Success record. We're confident of our products and provide no hassle product exchange. That's how confident we are!

99.3% Pass Rate
Was: $137.49
Now: $124.99

Network Appliance NS0-165 Practice Test 44

Question 430

A NetApp ONTAP administrator must resolve this situation: A Linux multipath configuration uses only one iSCSI session. Select TWO: the targeted corrective action and its strongest verification. (Select TWO.)

  1. Configure supported host multipath software and ONTAP SAN paths so failover remains possible and optimized or nonoptimized path states are handled appropriately.
  2. Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data.
  3. Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails.
  4. The host detects the intended expanded block device and its filesystem grows without altering unrelated disks.
  5. A controlled path failure leaves the host device online and its multipath utility shows expected surviving paths.

Explanation

Correct Answers

A:

This is the proposed corrective action for: A Linux multipath configuration uses only one iSCSI session. The action addresses the ONTAP failure mechanism: A single path or incorrect MPIO configuration can cause application outages despite a healthy storage HA pair.

E:

This provides separate verification for the same issue: A Linux multipath configuration uses only one iSCSI session. The outcome tests whether remediation is effective and can be recorded as acceptance evidence.

Incorrect Answers

B:

Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data. This does not supply the required san host multipathing and alua path state action-and-control pair.

C:

Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails. The paired controls concern san host multipathing and alua path state, not that measure.

D:

The host detects the intended expanded block device and its filesystem grows without altering unrelated disks. The san host multipathing and alua path state implementation and safeguard are still missing.

Question 431

During a storage operations review for a university research storage team, the team observes: A host keeps IO on a failed or unpreferred path because path-state handling is wrong. The decision must maintain shared-client safety and reproducible workloads. Which change best corrects the storage design under these conditions?

  1. Configure supported host multipath software and ONTAP SAN paths so failover remains possible and optimized or nonoptimized path states are handled appropriately.
  2. Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails.
  3. Coordinate ONTAP LUN or namespace capacity changes with host rescan and filesystem growth procedures.
  4. Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data.

Explanation

Correct Answer

A:

This action addresses the reported ONTAP condition: A host keeps IO on a failed or unpreferred path because path-state handling is wrong. It specifically applies san host multipathing and alua path state and mitigates: A single path or incorrect MPIO configuration can cause application outages despite a healthy storage HA pair. A practical completion check is: A controlled path failure leaves the host device online and its multipath utility shows expected surviving paths.

Incorrect Answers

B:

Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails. The configuration must instead establish san host multipathing and alua path state.

C:

Coordinate ONTAP LUN or namespace capacity changes with host rescan and filesystem growth procedures. The san host multipathing and alua path state prerequisite remains unaddressed.

D:

Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data. It changes a different feature than san host multipathing and alua path state.

Question 432

After corrective work for the ONTAP issue 'A host keeps IO on a failed or unpreferred path because path-state handling is wrong', the operator seeks objective signoff. What evidence would show that the corrective configuration is working?

  1. Corrected FC zoning or port state restores expected target visibility and multipathing without touching data blocks.
  2. The host detects the intended expanded block device and its filesystem grows without altering unrelated disks.
  3. A controlled path failure leaves the host device online and its multipath utility shows expected surviving paths.
  4. The initiator logs into the correct target over an allowed network and receives the expected mapped device.

Explanation

Correct Answer

C:

This is observable acceptance evidence for: A host keeps IO on a failed or unpreferred path because path-state handling is wrong. It demonstrates the intended ONTAP storage behavior in the relevant situation, rather than merely showing that a configuration field exists.

Incorrect Answers

A:

Corrected FC zoning or port state restores expected target visibility and multipathing without touching data blocks. Acceptance here depends on observing san host multipathing and alua path state, not only that test.

B:

The host detects the intended expanded block device and its filesystem grows without altering unrelated disks. It does not establish the requested san host multipathing and alua path state outcome.

D:

The initiator logs into the correct target over an allowed network and receives the expected mapped device. That result could pass without demonstrating san host multipathing and alua path state.

Question 433

During a storage operations review for a regulated healthcare records provider, the team observes: An ONTAP LUN is expanded but Windows still shows its old disk size. The decision must maintain patient data and application recovery obligations. Which ONTAP administration change best addresses the observed failure?

  1. Coordinate ONTAP LUN or namespace capacity changes with host rescan and filesystem growth procedures.
  2. Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails.
  3. Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data.
  4. Configure supported host multipath software and ONTAP SAN paths so failover remains possible and optimized or nonoptimized path states are handled appropriately.

Explanation

Correct Answer

A:

This action addresses the reported ONTAP condition: An ONTAP LUN is expanded but Windows still shows its old disk size. It specifically applies san device size and rescan coordination and mitigates: A volume resize alone does not guarantee that the operating system or application sees additional block space. A practical completion check is: The host detects the intended expanded block device and its filesystem grows without altering unrelated disks.

Incorrect Answers

B:

Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails. It changes a different feature than san device size and rescan coordination.

C:

Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data. That change would not implement san device size and rescan coordination.

D:

Configure supported host multipath software and ONTAP SAN paths so failover remains possible and optimized or nonoptimized path states are handled appropriately. The configuration must instead establish san device size and rescan coordination.

Question 434

After corrective work for the ONTAP issue 'An ONTAP LUN is expanded but Windows still shows its old disk size', the operator seeks objective signoff. Which acceptance result demonstrates that this ONTAP issue has been corrected?

  1. The host detects the intended expanded block device and its filesystem grows without altering unrelated disks.
  2. A controlled path failure leaves the host device online and its multipath utility shows expected surviving paths.
  3. Corrected FC zoning or port state restores expected target visibility and multipathing without touching data blocks.
  4. The initiator logs into the correct target over an allowed network and receives the expected mapped device.

Explanation

Correct Answer

A:

This is observable acceptance evidence for: An ONTAP LUN is expanded but Windows still shows its old disk size. It demonstrates the intended ONTAP storage behavior in the relevant situation, rather than merely showing that a configuration field exists.

Incorrect Answers

B:

A controlled path failure leaves the host device online and its multipath utility shows expected surviving paths. That result could pass without demonstrating san device size and rescan coordination.

C:

Corrected FC zoning or port state restores expected target visibility and multipathing without touching data blocks. Acceptance here depends on observing san device size and rescan coordination, not only that test.

D:

The initiator logs into the correct target over an allowed network and receives the expected mapped device. It does not establish the requested san device size and rescan coordination outcome.

Question 435

During a storage operations review for a university research storage team, the team observes: An administrator grows a containing FlexVol and expects the LUN size to increase automatically. The decision must maintain shared-client safety and reproducible workloads. What should the storage administrator do first for the stated requirement?

  1. Coordinate ONTAP LUN or namespace capacity changes with host rescan and filesystem growth procedures.
  2. Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data.
  3. Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails.
  4. Configure supported host multipath software and ONTAP SAN paths so failover remains possible and optimized or nonoptimized path states are handled appropriately.

Explanation

Correct Answer

A:

This action addresses the reported ONTAP condition: An administrator grows a containing FlexVol and expects the LUN size to increase automatically. It specifically applies san device size and rescan coordination and mitigates: A volume resize alone does not guarantee that the operating system or application sees additional block space. A practical completion check is: The host detects the intended expanded block device and its filesystem grows without altering unrelated disks.

Incorrect Answers

B:

Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data. The configuration must instead establish san device size and rescan coordination.

C:

Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails. The san device size and rescan coordination prerequisite remains unaddressed.

D:

Configure supported host multipath software and ONTAP SAN paths so failover remains possible and optimized or nonoptimized path states are handled appropriately. It changes a different feature than san device size and rescan coordination.

Question 436

After corrective work for the ONTAP issue 'An administrator grows a containing FlexVol and expects the LUN size to increase automatically', the operator seeks objective signoff. What observable test should the operator require before closing this issue?

  1. The host detects the intended expanded block device and its filesystem grows without altering unrelated disks.
  2. A controlled path failure leaves the host device online and its multipath utility shows expected surviving paths.
  3. The initiator logs into the correct target over an allowed network and receives the expected mapped device.
  4. Corrected FC zoning or port state restores expected target visibility and multipathing without touching data blocks.

Explanation

Correct Answer

A:

This is observable acceptance evidence for: An administrator grows a containing FlexVol and expects the LUN size to increase automatically. It demonstrates the intended ONTAP storage behavior in the relevant situation, rather than merely showing that a configuration field exists.

Incorrect Answers

B:

A controlled path failure leaves the host device online and its multipath utility shows expected surviving paths. The san device size and rescan coordination prerequisite remains unaddressed.

C:

The initiator logs into the correct target over an allowed network and receives the expected mapped device. It changes a different feature than san device size and rescan coordination.

D:

Corrected FC zoning or port state restores expected target visibility and multipathing without touching data blocks. That change would not implement san device size and rescan coordination.

Question 437

During a storage operations review for a regional managed storage service provider, the team observes: A host rescans the wrong bus and cannot locate the resized device. The decision must maintain tenant boundaries and documented service commitments. Which engineering choice most directly solves this problem?

  1. Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data.
  2. Configure supported host multipath software and ONTAP SAN paths so failover remains possible and optimized or nonoptimized path states are handled appropriately.
  3. Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails.
  4. Coordinate ONTAP LUN or namespace capacity changes with host rescan and filesystem growth procedures.

Explanation

Correct Answer

D:

This action addresses the reported ONTAP condition: A host rescans the wrong bus and cannot locate the resized device. It specifically applies san device size and rescan coordination and mitigates: A volume resize alone does not guarantee that the operating system or application sees additional block space. A practical completion check is: The host detects the intended expanded block device and its filesystem grows without altering unrelated disks.

Incorrect Answers

A:

Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data. The san device size and rescan coordination prerequisite remains unaddressed.

B:

Configure supported host multipath software and ONTAP SAN paths so failover remains possible and optimized or nonoptimized path states are handled appropriately. It changes a different feature than san device size and rescan coordination.

C:

Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails. That change would not implement san device size and rescan coordination.

Question 438

A NetApp ONTAP change review identifies: A host rescans the wrong bus and cannot locate the resized device. Which consequence should the administrator prioritize in this situation?

  1. Blindly recreating a LUN cannot fix an unreachable portal or mismatched authentication credentials.
  2. A single path or incorrect MPIO configuration can cause application outages despite a healthy storage HA pair.
  3. A fabric path failure can look like inaccessible storage while the ONTAP LUN and volume remain healthy.
  4. A volume resize alone does not guarantee that the operating system or application sees additional block space.

Explanation

Correct Answer

D:

This is the directly implicated exposure when a host rescans the wrong bus and cannot locate the resized device. The relevant corrective control is: Coordinate ONTAP LUN or namespace capacity changes with host rescan and filesystem growth procedures. A meaningful acceptance test is: The host detects the intended expanded block device and its filesystem grows without altering unrelated disks.

Incorrect Answers

A:

Blindly recreating a LUN cannot fix an unreachable portal or mismatched authentication credentials. It changes a different feature than san device size and rescan coordination.

B:

A single path or incorrect MPIO configuration can cause application outages despite a healthy storage HA pair. That change would not implement san device size and rescan coordination.

C:

A fabric path failure can look like inaccessible storage while the ONTAP LUN and volume remain healthy. The configuration must instead establish san device size and rescan coordination.

Question 439

During a storage operations review for an enterprise disaster recovery review, the team observes: A planned block shrink is attempted without checking filesystem safety. The decision must maintain preservation of recoverable data under controlled change. Which change best corrects the storage design under these conditions?

  1. Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails.
  2. Coordinate ONTAP LUN or namespace capacity changes with host rescan and filesystem growth procedures.
  3. Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data.
  4. Configure supported host multipath software and ONTAP SAN paths so failover remains possible and optimized or nonoptimized path states are handled appropriately.

Explanation

Correct Answer

B:

This action addresses the reported ONTAP condition: A planned block shrink is attempted without checking filesystem safety. It specifically applies san device size and rescan coordination and mitigates: A volume resize alone does not guarantee that the operating system or application sees additional block space. A practical completion check is: The host detects the intended expanded block device and its filesystem grows without altering unrelated disks.

Incorrect Answers

A:

Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails. That change would not implement san device size and rescan coordination.

C:

Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data. The san device size and rescan coordination prerequisite remains unaddressed.

D:

Configure supported host multipath software and ONTAP SAN paths so failover remains possible and optimized or nonoptimized path states are handled appropriately. It changes a different feature than san device size and rescan coordination.

Question 440

A NetApp ONTAP administrator must resolve this situation: A planned block shrink is attempted without checking filesystem safety. Which TWO choices form a defensible remediation-and-acceptance pair? (Select TWO.)

  1. Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data.
  2. Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails.
  3. A controlled path failure leaves the host device online and its multipath utility shows expected surviving paths.
  4. Coordinate ONTAP LUN or namespace capacity changes with host rescan and filesystem growth procedures.
  5. The host detects the intended expanded block device and its filesystem grows without altering unrelated disks.

Explanation

Correct Answers

D:

This is the proposed corrective action for: A planned block shrink is attempted without checking filesystem safety. The action addresses the ONTAP failure mechanism: A volume resize alone does not guarantee that the operating system or application sees additional block space.

E:

This provides separate verification for the same issue: A planned block shrink is attempted without checking filesystem safety. The outcome tests whether remediation is effective and can be recorded as acceptance evidence.

Incorrect Answers

A:

Inspect switch login state, target WWPNs, zoning, HBA health and ONTAP target LIFs before modifying LUN data. The paired controls concern san device size and rescan coordination, not that measure.

B:

Check target portals, initiator identity, CHAP or other configured authentication, ACLs and TCP reachability when iSCSI login fails. The san device size and rescan coordination implementation and safeguard are still missing.

C:

A controlled path failure leaves the host device online and its multipath utility shows expected surviving paths. It is not the complementary risk control for san device size and rescan coordination.

NetApp Certified Data Administrator, ONTAP (NS0-165) Practice Tests