Question 750
A new QFX leaf responds to management pings while the Apstra device manager reports no valid agent identity. Which controlled change best addresses the described requirement?
Explanation
Correct Answer
This action addresses the stated defect: install or repair the supported agent and associate the correct device identity through approved onboarding. The underlying constraint is that Apstra fabric onboarding needs a compatible managed agent and correctly established system identity, not only IP connectivity. Verify rather than assume success: confirm the device appears healthy, available and uniquely identified for blueprint assignment.
Incorrect Answers
That choice—“Assign the replacement supported system to the correct logical role using the documented controlled process”—addresses this other problem: A failed managed switch is swapped physically yet Apstra refuses deployment to the replacement inventory device. Here the scenario is: A new QFX leaf responds to management pings while the Apstra device manager reports no valid agent identity. Install or repair the supported agent and associate the correct device identity through approved onboarding. The most relevant correction is “Install or repair the supported agent and associate the correct device identity through approved onboarding”.
“Correct the duplicate device registration and assign each real device its own validated identity” is associated with a distinct issue: A deployment team duplicates a device-system ID when registering two new leaf switches. By contrast, the actual problem is: A new QFX leaf responds to management pings while the Apstra device manager reports no valid agent identity. Install or repair the supported agent and associate the correct device identity through approved onboarding. The most relevant correction is “Install or repair the supported agent and associate the correct device identity through approved onboarding”.
The option “Correct physical cabling or update the approved design only after confirming the intended topology” is useful in a different setting: A newly staged fabric reports LLDP neighbor mismatches although physical links are up. The case being tested is: A new QFX leaf responds to management pings while the Apstra device manager reports no valid agent identity. Install or repair the supported agent and associate the correct device identity through approved onboarding. The most relevant correction is “Install or repair the supported agent and associate the correct device identity through approved onboarding”.