Question 660
The HPE AOS-CX switching case is: A technician backs up the wrong VSF stack member and cannot recover the conductor configuration after hardware failure. Select TWO: a corrective switching action and separate evidence that the correction worked. (Select TWO.)
Explanation
Correct Answers
The targeted correction for A technician backs up the wrong VSF stack member and cannot recover the conductor configuration after hardware failure is: Verify that approved configuration was saved to startup, back up the previous state and test recovery before restarting a switch. It reduces the risk that an unsaved edit disappears on reboot while a mistakenly persisted temporary setting survives beyond its intended scope.
A separate operational validation for A technician backs up the wrong VSF stack member and cannot recover the conductor configuration after hardware failure is: After a controlled reboot the expected interface, VLAN and management state persists and a previous baseline can be restored. It proves intended behavior instead of accepting configuration presence alone.
Incorrect Answers
This alternative concerns maintenance window communication and change approval; its associated risk is: A technically correct change performed without coordination can interrupt critical services and prevent recovery within the approved outage allowance. The observed case A technician backs up the wrong VSF stack member and cannot recover the conductor configuration after hardware failure requires the more specific config restore and startup persistence protection control. The targeted action is: Verify that approved configuration was saved to startup, back up the previous state and test recovery before restarting a switch.
This alternative concerns scheduled configuration audit and desired-state compliance; its associated risk is: Undetected local overrides and drift can accumulate across branches and weaken segmentation or network reliability. The observed case A technician backs up the wrong VSF stack member and cannot recover the conductor configuration after hardware failure requires the more specific config restore and startup persistence protection control. The targeted action is: Verify that approved configuration was saved to startup, back up the previous state and test recovery before restarting a switch.
This alternative concerns handoff documentation and operational runbook maintenance; its associated risk is: Unrecorded VLAN or peer-role changes can turn routine incidents into extended outages and make compliance review unreliable. The observed case A technician backs up the wrong VSF stack member and cannot recover the conductor configuration after hardware failure requires the more specific config restore and startup persistence protection control. The targeted action is: Verify that approved configuration was saved to startup, back up the previous state and test recovery before restarting a switch.