Question 310
An operations team investigates this FortiSwitch 7.6 situation: An office network has a FortiGate controller but the cabling diagram does not identify its managed-switch uplink. Select TWO complementary measures: the corrective action AND evidence that it worked.
Explanation
Correct Answer
For the observed condition (An office network has a FortiGate controller but the cabling diagram does not identify its managed-switch uplink), the appropriate response is to use a supported FortiGate-to-FortiSwitch FortiLink design with documented management and data VLAN paths. The underlying risk is that treating any Layer 2 cable as a validated FortiLink management topology can conceal discovery and control-plane problems. This action is targeted to single fortigate managed topology rather than to a different switching feature. Confirm it by checking that topology inventory shows the FortiGate as controller and each managed switch reachable by the supported path.
The relevant acceptance proof for this incident (An office network has a FortiGate controller but the cabling diagram does not identify its managed-switch uplink) is: Topology inventory shows the FortiGate as controller and each managed switch reachable by the supported path. That observation tests the same failure path that prompted the change, not merely whether a physical link is up. It also helps rule out the known alternative risk: Treating any Layer 2 cable as a validated FortiLink management topology can conceal discovery and control-plane problems. Retain the documented evidence after applying the associated correction: Use a supported FortiGate-to-FortiSwitch FortiLink design with documented management and data VLAN paths.
Incorrect Answers
Interconnecting separate fortilink fabrics addresses another technical failure: an inter-fabric cable that enables automatic switch discovery can cause one controller to attempt management of the other fabric. The case states: An office network has a FortiGate controller but the cabling diagram does not identify its managed-switch uplink. The most direct paired action and test is: use a supported FortiGate-to-FortiSwitch FortiLink design with documented management and data VLAN paths.
Fortigate ha fortilink resilience addresses another technical failure: duplicate independent links to both HA members are not automatically a supported managed-switch failover design. The required paired action and test concerns Single fortigate managed topology; a passing result for this alternative could leave that requirement unresolved.
Two-tier managed switch design would demonstrate or implement: Topology discovery and permitted VLAN path checks prove access switches remain manageable through distribution uplinks. The paired-answer requirement concerns Single fortigate managed topology; this alternative does not provide the matching intervention and separate acceptance evidence.