mcAfee Secure Website
exam =5
exam =6

Exam Code: NSE5_FSW_AD-7.6

Exam Name: Fortinet NSE 5 - FortiSwitch 7.6 Administrator

Certification Provider: Fortinet

Corresponding Certification: NSE5

Fortinet NSE5_FSW_AD-7.6 Questions & Answers

Reliable & Actual Study Materials for NSE5_FSW_AD-7.6 Exam Success

64 Questions & Answers with Testing Engine

"NSE5_FSW_AD-7.6: Fortinet NSE 5 - FortiSwitch 7.6 Administrator" Testing Engine covers all the knowledge points of the real Fortinet NSE5_FSW_AD-7.6 exam.

The latest actual NSE5_FSW_AD-7.6 Questions & Answers from Pass4sure. Everything you need to prepare and get best score at NSE5_FSW_AD-7.6 exam easily and quickly.

exam =7
Guarantee

Satisfaction Guaranteed

Pass4sure has a remarkable Fortinet Candidate Success record. We're confident of our products and provide no hassle product exchange. That's how confident we are!

99.3% Pass Rate
Was: $137.49
Now: $124.99

Fortinet NSE5_FSW_AD-7.6 Practice Test 21

Question 200

An operations team investigates this FortiSwitch 7.6 situation: An uplink remains in an unplanned role because neighboring switches disagree about MST configuration. Select TWO complementary measures: the corrective action AND evidence that it worked.

  1. Use BPDU guard on genuine edge ports to disable or protect ports that unexpectedly receive BPDUs.
  2. Use RSTP with appropriate link roles to obtain prompt loop-free convergence after planned path failures.
  3. Bridge and root identifiers identify the planned root and expected forwarding and alternate port roles.
  4. Check that cooperating switches use compatible MSTP region attributes and VLAN-to-instance mapping.
  5. MST region digest and per-instance root and port states agree across intended peers.

Explanation

Correct Answer

D:

For the observed condition (An uplink remains in an unplanned role because neighboring switches disagree about MST configuration), the appropriate response is to check that cooperating switches use compatible MSTP region attributes and VLAN-to-instance mapping. The underlying risk is that different MST region configuration can prevent the expected spanning-tree instance topology from forming across neighbors. This action is targeted to mstp instance and vlan mapping rather than to a different switching feature. Confirm it by checking that mST region digest and per-instance root and port states agree across intended peers.

E:

The relevant acceptance proof for this incident (An uplink remains in an unplanned role because neighboring switches disagree about MST configuration) is: MST region digest and per-instance root and port states agree across intended peers. That observation tests the same failure path that prompted the change, not merely whether a physical link is up. It also helps rule out the known alternative risk: Different MST region configuration can prevent the expected spanning-tree instance topology from forming across neighbors. Retain the documented evidence after applying the associated correction: Check that cooperating switches use compatible MSTP region attributes and VLAN-to-instance mapping.

Incorrect Answers

A:

Bpdu guard on endpoint ports addresses another technical failure: applying BPDU guard indiscriminately to infrastructure uplinks can shut down legitimate switch-to-switch links. The case states: An uplink remains in an unplanned role because neighboring switches disagree about MST configuration. The most direct paired action and test is: check that cooperating switches use compatible MSTP region attributes and VLAN-to-instance mapping.

B:

Rstp rapid recovery addresses another technical failure: disabling STP on redundant Layer 2 links hides loops rather than improving recovery. This choice can be useful for that problem, but it does not establish the Mstp instance and VLAN mapping control being assessed here.

C:

Stp root bridge placement would demonstrate or implement: Bridge and root identifiers identify the planned root and expected forwarding and alternate port roles. This case instead tests Mstp instance and VLAN mapping; the choice measures or changes another part of the system.

Question 201

At a FortiSwitchOS/FortiOS 7.6 network site, an engineer observes: A 10Gb uplink remains dark after a short-reach optic is installed on the wrong fiber type. Which change MOST DIRECTLY addresses this problem without weakening the intended network design?

  1. Check port speed negotiation and physical error counters before changing unrelated switching policies.
  2. Use only the model-supported split-port or breakout configuration and appropriate breakout cabling.
  3. Select an optic and fiber or copper medium explicitly supported by both device models and port specifications.
  4. Validate the switch-wide PoE power budget and per-port requirements before enabling additional powered endpoints.

Explanation

Correct Answer

C:

For the observed condition (A 10Gb uplink remains dark after a short-reach optic is installed on the wrong fiber type), the appropriate response is to select an optic and fiber or copper medium explicitly supported by both device models and port specifications. The underlying risk is that matching the connector shape alone cannot prove the transceiver supports the wavelength, reach, or port speed. This action is targeted to optic and transceiver compatibility rather than to a different switching feature. Confirm it by checking that the transceiver inventory reports compatible modules and the end-to-end link negotiates stably without excessive errors.

Incorrect Answers

A:

Speed duplex and physical diagnostics addresses another technical failure: repeated CRC or FCS errors from a physical mismatch are not solved by enlarging the VLAN allowed list. The case states: A 10Gb uplink remains dark after a short-reach optic is installed on the wrong fiber type. The most direct corrective action is: select an optic and fiber or copper medium explicitly supported by both device models and port specifications.

B:

Split-port breakout support addresses another technical failure: a physically available high-speed socket cannot always be subdivided into arbitrary child-port speeds. This choice can be useful for that problem, but it does not establish the Optic and transceiver compatibility control being assessed here.

D:

Poe budget and power priority addresses another technical failure: a free physical Ethernet socket does not imply sufficient remaining power for every access point or camera. The required corrective action concerns Optic and transceiver compatibility; a passing result for this alternative could leave that requirement unresolved.

Question 202

After diagnosing the FortiSwitch 7.6 issue, the engineer records: A 10Gb uplink remains dark after a short-reach optic is installed on the wrong fiber type. Which acceptance evidence MOST DIRECTLY demonstrates the specific correction succeeded?

  1. The transceiver inventory reports compatible modules and the end-to-end link negotiates stably without excessive errors.
  2. The link negotiates the intended speed and duplex and error counts stop increasing under traffic.
  3. Inventory and port status confirm the expected child interfaces are present and all attach at supported rates.
  4. Total allocated PoE power stays within the platform limit and endpoints remain powered during a load test.

Explanation

Correct Answer

A:

The relevant acceptance proof for this incident (A 10Gb uplink remains dark after a short-reach optic is installed on the wrong fiber type) is: The transceiver inventory reports compatible modules and the end-to-end link negotiates stably without excessive errors. That observation tests the same failure path that prompted the change, not merely whether a physical link is up. It also helps rule out the known alternative risk: Matching the connector shape alone cannot prove the transceiver supports the wavelength, reach, or port speed. Retain the documented evidence after applying the associated correction: Select an optic and fiber or copper medium explicitly supported by both device models and port specifications.

Incorrect Answers

B:

Speed duplex and physical diagnostics would demonstrate or implement: The link negotiates the intended speed and duplex and error counts stop increasing under traffic. This choice can be useful for that problem, but it does not establish the Optic and transceiver compatibility control being assessed here.

C:

Split-port breakout support would demonstrate or implement: Inventory and port status confirm the expected child interfaces are present and all attach at supported rates. This case instead tests Optic and transceiver compatibility; the choice measures or changes another part of the system.

D:

Poe budget and power priority would demonstrate or implement: Total allocated PoE power stays within the platform limit and endpoints remain powered during a load test. The required evidence concerns Optic and transceiver compatibility; a passing result for this alternative could leave that requirement unresolved.

Question 203

At a FortiSwitchOS/FortiOS 7.6 network site, an engineer observes: A technician fits an SFP module physically but the switch flags it as unsupported. Which change MOST DIRECTLY addresses this problem without weakening the intended network design?

  1. Use only the model-supported split-port or breakout configuration and appropriate breakout cabling.
  2. Validate the switch-wide PoE power budget and per-port requirements before enabling additional powered endpoints.
  3. Select an optic and fiber or copper medium explicitly supported by both device models and port specifications.
  4. Check port speed negotiation and physical error counters before changing unrelated switching policies.

Explanation

Correct Answer

C:

For the observed condition (A technician fits an SFP module physically but the switch flags it as unsupported), the appropriate response is to select an optic and fiber or copper medium explicitly supported by both device models and port specifications. The underlying risk is that matching the connector shape alone cannot prove the transceiver supports the wavelength, reach, or port speed. This action is targeted to optic and transceiver compatibility rather than to a different switching feature. Confirm it by checking that the transceiver inventory reports compatible modules and the end-to-end link negotiates stably without excessive errors.

Incorrect Answers

A:

Split-port breakout support addresses another technical failure: a physically available high-speed socket cannot always be subdivided into arbitrary child-port speeds. The case states: A technician fits an SFP module physically but the switch flags it as unsupported. The most direct corrective action is: select an optic and fiber or copper medium explicitly supported by both device models and port specifications.

B:

Poe budget and power priority addresses another technical failure: a free physical Ethernet socket does not imply sufficient remaining power for every access point or camera. This choice can be useful for that problem, but it does not establish the Optic and transceiver compatibility control being assessed here.

D:

Speed duplex and physical diagnostics addresses another technical failure: repeated CRC or FCS errors from a physical mismatch are not solved by enlarging the VLAN allowed list. The required corrective action concerns Optic and transceiver compatibility; a passing result for this alternative could leave that requirement unresolved.

Question 204

After diagnosing the FortiSwitch 7.6 issue, the engineer records: A technician fits an SFP module physically but the switch flags it as unsupported. Which acceptance evidence MOST DIRECTLY demonstrates the specific correction succeeded?

  1. Inventory and port status confirm the expected child interfaces are present and all attach at supported rates.
  2. Total allocated PoE power stays within the platform limit and endpoints remain powered during a load test.
  3. The link negotiates the intended speed and duplex and error counts stop increasing under traffic.
  4. The transceiver inventory reports compatible modules and the end-to-end link negotiates stably without excessive errors.

Explanation

Correct Answer

D:

The relevant acceptance proof for this incident (A technician fits an SFP module physically but the switch flags it as unsupported) is: The transceiver inventory reports compatible modules and the end-to-end link negotiates stably without excessive errors. That observation tests the same failure path that prompted the change, not merely whether a physical link is up. It also helps rule out the known alternative risk: Matching the connector shape alone cannot prove the transceiver supports the wavelength, reach, or port speed. Retain the documented evidence after applying the associated correction: Select an optic and fiber or copper medium explicitly supported by both device models and port specifications.

Incorrect Answers

A:

Split-port breakout support would demonstrate or implement: Inventory and port status confirm the expected child interfaces are present and all attach at supported rates. The case states: A technician fits an SFP module physically but the switch flags it as unsupported. The most direct evidence is: The transceiver inventory reports compatible modules and the end-to-end link negotiates stably without excessive errors.

B:

Poe budget and power priority would demonstrate or implement: Total allocated PoE power stays within the platform limit and endpoints remain powered during a load test. This choice can be useful for that problem, but it does not establish the Optic and transceiver compatibility control being assessed here.

C:

Speed duplex and physical diagnostics would demonstrate or implement: The link negotiates the intended speed and duplex and error counts stop increasing under traffic. This case instead tests Optic and transceiver compatibility; the choice measures or changes another part of the system.

Question 205

At a FortiSwitchOS/FortiOS 7.6 network site, an engineer observes: A distant IDF link fails when both ends use incompatible optical wavelengths. Which change MOST DIRECTLY addresses this problem without weakening the intended network design?

  1. Validate the switch-wide PoE power budget and per-port requirements before enabling additional powered endpoints.
  2. Select an optic and fiber or copper medium explicitly supported by both device models and port specifications.
  3. Check port speed negotiation and physical error counters before changing unrelated switching policies.
  4. Use only the model-supported split-port or breakout configuration and appropriate breakout cabling.

Explanation

Correct Answer

B:

For the observed condition (A distant IDF link fails when both ends use incompatible optical wavelengths), the appropriate response is to select an optic and fiber or copper medium explicitly supported by both device models and port specifications. The underlying risk is that matching the connector shape alone cannot prove the transceiver supports the wavelength, reach, or port speed. This action is targeted to optic and transceiver compatibility rather than to a different switching feature. Confirm it by checking that the transceiver inventory reports compatible modules and the end-to-end link negotiates stably without excessive errors.

Incorrect Answers

A:

Poe budget and power priority addresses another technical failure: a free physical Ethernet socket does not imply sufficient remaining power for every access point or camera. The case states: A distant IDF link fails when both ends use incompatible optical wavelengths. The most direct corrective action is: select an optic and fiber or copper medium explicitly supported by both device models and port specifications.

C:

Speed duplex and physical diagnostics addresses another technical failure: repeated CRC or FCS errors from a physical mismatch are not solved by enlarging the VLAN allowed list. This case instead tests Optic and transceiver compatibility; the choice measures or changes another part of the system.

D:

Split-port breakout support addresses another technical failure: a physically available high-speed socket cannot always be subdivided into arbitrary child-port speeds. The required corrective action concerns Optic and transceiver compatibility; a passing result for this alternative could leave that requirement unresolved.

Question 206

After diagnosing the FortiSwitch 7.6 issue, the engineer records: A distant IDF link fails when both ends use incompatible optical wavelengths. Which acceptance evidence MOST DIRECTLY demonstrates the specific correction succeeded?

  1. The transceiver inventory reports compatible modules and the end-to-end link negotiates stably without excessive errors.
  2. Total allocated PoE power stays within the platform limit and endpoints remain powered during a load test.
  3. The link negotiates the intended speed and duplex and error counts stop increasing under traffic.
  4. Inventory and port status confirm the expected child interfaces are present and all attach at supported rates.

Explanation

Correct Answer

A:

The relevant acceptance proof for this incident (A distant IDF link fails when both ends use incompatible optical wavelengths) is: The transceiver inventory reports compatible modules and the end-to-end link negotiates stably without excessive errors. That observation tests the same failure path that prompted the change, not merely whether a physical link is up. It also helps rule out the known alternative risk: Matching the connector shape alone cannot prove the transceiver supports the wavelength, reach, or port speed. Retain the documented evidence after applying the associated correction: Select an optic and fiber or copper medium explicitly supported by both device models and port specifications.

Incorrect Answers

B:

Poe budget and power priority would demonstrate or implement: Total allocated PoE power stays within the platform limit and endpoints remain powered during a load test. This choice can be useful for that problem, but it does not establish the Optic and transceiver compatibility control being assessed here.

C:

Speed duplex and physical diagnostics would demonstrate or implement: The link negotiates the intended speed and duplex and error counts stop increasing under traffic. This case instead tests Optic and transceiver compatibility; the choice measures or changes another part of the system.

D:

Split-port breakout support would demonstrate or implement: Inventory and port status confirm the expected child interfaces are present and all attach at supported rates. The required evidence concerns Optic and transceiver compatibility; a passing result for this alternative could leave that requirement unresolved.

Question 207

At a FortiSwitchOS/FortiOS 7.6 network site, an engineer observes: An interbuilding circuit has the right cable connector but not the required reach budget. Which change MOST DIRECTLY addresses this problem without weakening the intended network design?

  1. Check port speed negotiation and physical error counters before changing unrelated switching policies.
  2. Use only the model-supported split-port or breakout configuration and appropriate breakout cabling.
  3. Validate the switch-wide PoE power budget and per-port requirements before enabling additional powered endpoints.
  4. Select an optic and fiber or copper medium explicitly supported by both device models and port specifications.

Explanation

Correct Answer

D:

For the observed condition (An interbuilding circuit has the right cable connector but not the required reach budget), the appropriate response is to select an optic and fiber or copper medium explicitly supported by both device models and port specifications. The underlying risk is that matching the connector shape alone cannot prove the transceiver supports the wavelength, reach, or port speed. This action is targeted to optic and transceiver compatibility rather than to a different switching feature. Confirm it by checking that the transceiver inventory reports compatible modules and the end-to-end link negotiates stably without excessive errors.

Incorrect Answers

A:

Speed duplex and physical diagnostics addresses another technical failure: repeated CRC or FCS errors from a physical mismatch are not solved by enlarging the VLAN allowed list. The case states: An interbuilding circuit has the right cable connector but not the required reach budget. The most direct corrective action is: select an optic and fiber or copper medium explicitly supported by both device models and port specifications.

B:

Split-port breakout support addresses another technical failure: a physically available high-speed socket cannot always be subdivided into arbitrary child-port speeds. This choice can be useful for that problem, but it does not establish the Optic and transceiver compatibility control being assessed here.

C:

Poe budget and power priority addresses another technical failure: a free physical Ethernet socket does not imply sufficient remaining power for every access point or camera. This case instead tests Optic and transceiver compatibility; the choice measures or changes another part of the system.

Question 208

After diagnosing the FortiSwitch 7.6 issue, the engineer records: An interbuilding circuit has the right cable connector but not the required reach budget. Which acceptance evidence MOST DIRECTLY demonstrates the specific correction succeeded?

  1. The link negotiates the intended speed and duplex and error counts stop increasing under traffic.
  2. The transceiver inventory reports compatible modules and the end-to-end link negotiates stably without excessive errors.
  3. Inventory and port status confirm the expected child interfaces are present and all attach at supported rates.
  4. Total allocated PoE power stays within the platform limit and endpoints remain powered during a load test.

Explanation

Correct Answer

B:

The relevant acceptance proof for this incident (An interbuilding circuit has the right cable connector but not the required reach budget) is: The transceiver inventory reports compatible modules and the end-to-end link negotiates stably without excessive errors. That observation tests the same failure path that prompted the change, not merely whether a physical link is up. It also helps rule out the known alternative risk: Matching the connector shape alone cannot prove the transceiver supports the wavelength, reach, or port speed. Retain the documented evidence after applying the associated correction: Select an optic and fiber or copper medium explicitly supported by both device models and port specifications.

Incorrect Answers

A:

Speed duplex and physical diagnostics would demonstrate or implement: The link negotiates the intended speed and duplex and error counts stop increasing under traffic. The case states: An interbuilding circuit has the right cable connector but not the required reach budget. The most direct evidence is: The transceiver inventory reports compatible modules and the end-to-end link negotiates stably without excessive errors.

C:

Split-port breakout support would demonstrate or implement: Inventory and port status confirm the expected child interfaces are present and all attach at supported rates. This case instead tests Optic and transceiver compatibility; the choice measures or changes another part of the system.

D:

Poe budget and power priority would demonstrate or implement: Total allocated PoE power stays within the platform limit and endpoints remain powered during a load test. The required evidence concerns Optic and transceiver compatibility; a passing result for this alternative could leave that requirement unresolved.

Question 209

At a FortiSwitchOS/FortiOS 7.6 network site, an engineer observes: A 25Gb access uplink reports module alarms because the selected optics differ from supported combinations. Which change MOST DIRECTLY addresses this problem without weakening the intended network design?

  1. Use only the model-supported split-port or breakout configuration and appropriate breakout cabling.
  2. Validate the switch-wide PoE power budget and per-port requirements before enabling additional powered endpoints.
  3. Select an optic and fiber or copper medium explicitly supported by both device models and port specifications.
  4. Check port speed negotiation and physical error counters before changing unrelated switching policies.

Explanation

Correct Answer

C:

For the observed condition (A 25Gb access uplink reports module alarms because the selected optics differ from supported combinations), the appropriate response is to select an optic and fiber or copper medium explicitly supported by both device models and port specifications. The underlying risk is that matching the connector shape alone cannot prove the transceiver supports the wavelength, reach, or port speed. This action is targeted to optic and transceiver compatibility rather than to a different switching feature. Confirm it by checking that the transceiver inventory reports compatible modules and the end-to-end link negotiates stably without excessive errors.

Incorrect Answers

A:

Split-port breakout support addresses another technical failure: a physically available high-speed socket cannot always be subdivided into arbitrary child-port speeds. The case states: A 25Gb access uplink reports module alarms because the selected optics differ from supported combinations. The most direct corrective action is: select an optic and fiber or copper medium explicitly supported by both device models and port specifications.

B:

Poe budget and power priority addresses another technical failure: a free physical Ethernet socket does not imply sufficient remaining power for every access point or camera. This choice can be useful for that problem, but it does not establish the Optic and transceiver compatibility control being assessed here.

D:

Speed duplex and physical diagnostics addresses another technical failure: repeated CRC or FCS errors from a physical mismatch are not solved by enlarging the VLAN allowed list. The required corrective action concerns Optic and transceiver compatibility; a passing result for this alternative could leave that requirement unresolved.

Question 210

An operations team investigates this FortiSwitch 7.6 situation: A 25Gb access uplink reports module alarms because the selected optics differ from supported combinations. Select TWO complementary measures: the corrective action AND evidence that it worked.

  1. Use only the model-supported split-port or breakout configuration and appropriate breakout cabling.
  2. Validate the switch-wide PoE power budget and per-port requirements before enabling additional powered endpoints.
  3. The link negotiates the intended speed and duplex and error counts stop increasing under traffic.
  4. Select an optic and fiber or copper medium explicitly supported by both device models and port specifications.
  5. The transceiver inventory reports compatible modules and the end-to-end link negotiates stably without excessive errors.

Explanation

Correct Answer

D:

For the observed condition (A 25Gb access uplink reports module alarms because the selected optics differ from supported combinations), the appropriate response is to select an optic and fiber or copper medium explicitly supported by both device models and port specifications. The underlying risk is that matching the connector shape alone cannot prove the transceiver supports the wavelength, reach, or port speed. This action is targeted to optic and transceiver compatibility rather than to a different switching feature. Confirm it by checking that the transceiver inventory reports compatible modules and the end-to-end link negotiates stably without excessive errors.

E:

The relevant acceptance proof for this incident (A 25Gb access uplink reports module alarms because the selected optics differ from supported combinations) is: The transceiver inventory reports compatible modules and the end-to-end link negotiates stably without excessive errors. That observation tests the same failure path that prompted the change, not merely whether a physical link is up. It also helps rule out the known alternative risk: Matching the connector shape alone cannot prove the transceiver supports the wavelength, reach, or port speed. Retain the documented evidence after applying the associated correction: Select an optic and fiber or copper medium explicitly supported by both device models and port specifications.

Incorrect Answers

A:

Split-port breakout support addresses another technical failure: a physically available high-speed socket cannot always be subdivided into arbitrary child-port speeds. The case states: A 25Gb access uplink reports module alarms because the selected optics differ from supported combinations. The most direct paired action and test is: select an optic and fiber or copper medium explicitly supported by both device models and port specifications.

B:

Poe budget and power priority addresses another technical failure: a free physical Ethernet socket does not imply sufficient remaining power for every access point or camera. This choice can be useful for that problem, but it does not establish the Optic and transceiver compatibility control being assessed here.

C:

Speed duplex and physical diagnostics would demonstrate or implement: The link negotiates the intended speed and duplex and error counts stop increasing under traffic. This case instead tests Optic and transceiver compatibility; the choice measures or changes another part of the system.

Fortinet NSE 5 - FortiSwitch 7.6 Administrator (NSE5_FSW_AD-7.6) Practice Tests