mcAfee Secure Website
exam =5
exam =6

Exam Code: 800-150

Exam Name: Supporting Cisco Devices for Field Technicians

Certification Provider: Cisco

Cisco 800-150 Questions & Answers

Reliable & Actual Study Materials for 800-150 Exam Success

100 Questions & Answers with Testing Engine

"800-150: Supporting Cisco Devices for Field Technicians" Testing Engine covers all the knowledge points of the real Cisco 800-150 exam.

The latest actual 800-150 Questions & Answers from Pass4sure. Everything you need to prepare and get best score at 800-150 exam easily and quickly.

exam =7
Guarantee

Satisfaction Guaranteed

Pass4sure has a remarkable Cisco Candidate Success record. We're confident of our products and provide no hassle product exchange. That's how confident we are!

99.3% Pass Rate
Was: $137.49
Now: $124.99

Cisco 800-150 Practice Test 42

Question 410

Remote office replacement window. Field report: The wrong NCS line card arrives for an RMA ticket. The shift lead must choose a return-to-service note for this ticket. Which handoff is technically adequate?

  1. Apply “Rename the received SKU in the ticket to make it compatible” as a substitute and declare success from shipment receipt alone.
  2. Defer service verification after “Swap unrelated WAN cables to bypass module mismatch” until the next reported incident.
  3. Perform or retain the approved action: compare received pid, sku and supported chassis/slot before insertion; document evidence that the shipment matches the approved compatible part inventory.
  4. Close after recording “Install the card because the serial number is close to the old one” without checking that the shipment matches the approved compatible part inventory.

Explanation

Correct Answer

C:

This handoff preserves the required corrective action and the verifiable service outcome. Spare hardware must be verified against supported field-replaceable product IDs. Recording that the shipment matches the approved compatible part inventory makes the signoff testable.

Incorrect Answers

A:

Delivery paperwork describes logistics, not recovered functionality. “Rename the received SKU in the ticket to make it compatible” leaves the technical requirement and its validation unresolved.

B:

A future incident is not a reasonable acceptance gate for a known problem. “Swap unrelated WAN cables to bypass module mismatch” is not evidence that the shipment matches the approved compatible part inventory.

D:

This proposes a different action with no acceptance evidence. “Install the card because the serial number is close to the old one” cannot replace the validated measure that the shipment matches the approved compatible part inventory.

Question 411

Disaster-recovery facility inspection. Field report: Receive power drops after a fiber cross-connect change. Which action is the most defensible first step?

  1. Assume interface speed mismatch is the only possible optical cause.
  2. Polish live optics with an abrasive cloth while powered.
  3. Raise software interface MTU to remove dust from connectors.
  4. Inspect and clean fiber end faces using approved procedures.

Explanation

Correct Answer

D:

Dirty fiber connectors increase optical insertion loss and can disrupt signal margin. The action should lead to evidence that cleanliness and receive power levels after proper recoupling.

Incorrect Answers

A:

Attempting this shortcut is not an adequate substitute for the required action. Dirty fiber connectors increase optical insertion loss and can disrupt signal margin. Post-change evidence is still needed.

B:

This alternative would not solve the reported problem. Dirty fiber connectors increase optical insertion loss and can disrupt signal margin. The field team must instead establish whether cleanliness and receive power levels after proper recoupling.

C:

That change addresses a different aspect of the environment and leaves this requirement unresolved: receive power drops after a fiber cross-connect change. The relevant control is inspect and clean fiber end faces using approved procedures.

Question 412

Main campus hardware-service ticket. Field report: An on-premise IP phone receives DHCP but stays unregistered. Which action is the most defensible first step?

  1. Check phone reachability to its assigned Cisco UCM/call-control service.
  2. Change campus spanning-tree root before checking call-control connectivity.
  3. Disable DNS globally without examining registration signaling.
  4. Replace the handset solely because it received an address.

Explanation

Correct Answer

A:

Phone address assignment does not prove call-control registration or provisioning. The action should lead to evidence that the phone shows registered in its intended call-control group.

Incorrect Answers

B:

That change addresses a different aspect of the environment and leaves this requirement unresolved: an on-premise ip phone receives dhcp but stays unregistered. The relevant control is check phone reachability to its assigned cisco ucm/call-control service.

C:

Attempting this shortcut is not an adequate substitute for the required action. Phone address assignment does not prove call-control registration or provisioning. Post-change evidence is still needed.

D:

This alternative would not solve the reported problem. Phone address assignment does not prove call-control registration or provisioning. The field team must instead establish whether the phone shows registered in its intended call-control group.

Question 413

Regional north-campus service window. Field report: TAC needs to distinguish the failed line card from the parent chassis. Which action is the most defensible first step?

  1. Use the switch STP root MAC as the replacement FRU serial.
  2. Capture the affected FRU serial and slot location from supported inventory.
  3. Assume every line card shares its chassis serial number.
  4. Send only the chassis management IP and omit the module ID.

Explanation

Correct Answer

B:

Field-replaceable modules can have separate serials and product identifiers. The action should lead to evidence that the failing FRU serial and location correspond to the RMA item.

Incorrect Answers

A:

Attempting this shortcut is not an adequate substitute for the required action. Field-replaceable modules can have separate serials and product identifiers. Post-change evidence is still needed.

C:

That change addresses a different aspect of the environment and leaves this requirement unresolved: tac needs to distinguish the failed line card from the parent chassis. The relevant control is capture the affected fru serial and slot location from supported inventory.

D:

This alternative would not solve the reported problem. Field-replaceable modules can have separate serials and product identifiers. The field team must instead establish whether the failing FRU serial and location correspond to the RMA item.

Question 414

Customer branch-site maintenance. Field report: A rack-mounted C-Series server must be remotely diagnosed before a drive replacement. The approved intervention is complete. What observation provides the strongest technical acceptance evidence?

  1. Confirm only that the work ticket says “completed,” without testing ucs c-series controller.
  2. Confirm the site inventory list still contains the hostname, without validating the reported service.
  3. Demonstrate that failed component identity and post-replacement storage health.
  4. Confirm only that the technician attempted: treat switch mac learning as proof that all disks are healthy.

Explanation

Correct Answer

C:

Failed component identity and post-replacement storage health. C-Series server hardware exposes diagnostic and inventory information through its management controller.

Incorrect Answers

A:

Check whether failed component identity and post-replacement storage health.

B:

Confirm that failed component identity and post-replacement storage health.

D:

For example, “Treat switch MAC learning as proof that all disks are healthy” does not demonstrate the corrected technical state.

Question 415

Primary data-center night shift. Field report: A replaced high-speed 8000 router card becomes operational but critical routes are missing. Which action is the most defensible first step?

  1. Use storage-controller zoning to repair missing IPv4 routes.
  2. Restart unrelated collaboration endpoints as routing acceptance.
  3. Declare recovery complete solely because optics show light.
  4. Inspect interface, forwarding, protocol adjacency and line-card state together.

Explanation

Correct Answer

D:

Hardware readiness must be paired with control-plane and forwarding validation. The action should lead to evidence that intended routes and test flows work through the new card.

Incorrect Answers

A:

That change addresses a different aspect of the environment and leaves this requirement unresolved: a replaced high-speed 8000 router card becomes operational but critical routes are missing. The relevant control is inspect interface, forwarding, protocol adjacency and line-card state together.

B:

Attempting this shortcut is not an adequate substitute for the required action. Hardware readiness must be paired with control-plane and forwarding validation. Post-change evidence is still needed.

C:

This alternative would not solve the reported problem. Hardware readiness must be paired with control-plane and forwarding validation. The field team must instead establish whether intended routes and test flows work through the new card.

Question 416

Headquarters wiring-closet visit. Field report: A router skips its expected startup configuration during a controlled recovery. The approved intervention is complete. What observation provides the strongest technical acceptance evidence?

  1. Demonstrate that the intended startup configuration loads after a validated reload.
  2. Confirm only that the work ticket says “completed,” without testing configuration register.
  3. Confirm the site inventory list still contains the hostname, without validating the reported service.
  4. Confirm only that the technician attempted: disable the console port to force the startup config to load.

Explanation

Correct Answer

A:

The intended startup configuration loads after a validated reload. Platform boot register settings can influence startup configuration use.

Incorrect Answers

B:

Check whether the intended startup configuration loads after a validated reload.

C:

Confirm that the intended startup configuration loads after a validated reload.

D:

For example, “Disable the console port to force the startup config to load” does not demonstrate the corrected technical state.

Question 417

Colocation site RMA handoff. Field report: An organization retains local UCM while integrating approved hosted collaboration functions. A colleague proposes: “Assume hybrid means all local equipment is immediately decommissioned.” Which technical assessment is best supported?

  1. The proposed shortcut is sufficient because replace a san switch with a public sip registrar without design review.
  2. The proposal overlooks the reported dependency: Hybrid architecture combines local and cloud functions with explicit integration points.
  3. The original problem can be treated as resolved from inventory labels alone, without checking hybrid deployment boundary behavior.
  4. There is no need to validate the reported dependency once treat an ntp source as the only hybrid federation control.

Explanation

Correct Answer

B:

The alternative does not address the actual reported dependency. Hybrid architecture combines local and cloud functions with explicit integration points. The supported intervention is document local call-control responsibilities and cloud integration dependencies; acceptance should show that intended on-premises services and cloud functions work across the supported integration.

Incorrect Answers

A:

The proposed step “Replace a SAN switch with a public SIP registrar without design review” is not the required mechanism.

C:

The failure described in the field report requires a functional check that intended on-premises services and cloud functions work across the supported integration.

D:

It assumes an unrelated action establishes service recovery. Nothing about “Treat an NTP source as the only hybrid federation control” demonstrates whether intended on-premises services and cloud functions work across the supported integration.

Question 418

Remote office replacement window. Field report: A UCS blade boots but cannot see the assigned SAN boot target. Which action is the most defensible first step?

  1. Change a Webex meeting URL to repair SAN boot storage.
  2. Assume Ethernet ping proves Fibre Channel initiator login.
  3. Check vHBA mapping, FC zoning, VSAN and fabric path for the server.
  4. Delete the VM hostname rather than checking vHBA paths.

Explanation

Correct Answer

C:

SAN boot requires correctly provisioned host bus access and storage fabric connectivity. The action should lead to evidence that the intended WWPN and LUN are visible through approved FC paths.

Incorrect Answers

A:

This alternative would not solve the reported problem. SAN boot requires correctly provisioned host bus access and storage fabric connectivity. The field team must instead establish whether the intended WWPN and LUN are visible through approved FC paths.

B:

That change addresses a different aspect of the environment and leaves this requirement unresolved: a ucs blade boots but cannot see the assigned san boot target. The relevant control is check vhba mapping, fc zoning, vsan and fabric path for the server.

D:

Attempting this shortcut is not an adequate substitute for the required action. SAN boot requires correctly provisioned host bus access and storage fabric connectivity. Post-change evidence is still needed.

Question 419

Disaster-recovery facility inspection. Field report: A packet capture shows IP packets carried inside Ethernet frames on the wire. A colleague proposes: “Treat TCP application payload as the physical cable encoding.” Which technical assessment is best supported?

  1. The proposed shortcut is sufficient because expect switch forwarding to remove the ip header at every hop.
  2. The original problem can be treated as resolved from inventory labels alone, without checking encapsulation order behavior.
  3. There is no need to validate the reported dependency once assume an ip packet contains no layer 2 envelope on a lan.
  4. The proposal overlooks the reported dependency: Ethernet supplies link-layer framing while IP carries inter-network addressing.

Explanation

Correct Answer

D:

The alternative does not address the actual reported dependency. Ethernet supplies link-layer framing while IP carries inter-network addressing. The supported intervention is interpret ethernet headers as the local link encapsulation around ip; acceptance should show that captured Ethernet frames contain the expected EtherType and IP packet.

Incorrect Answers

A:

The proposed step “Expect switch forwarding to remove the IP header at every hop” is not the required mechanism.

B:

The failure described in the field report requires a functional check that captured Ethernet frames contain the expected EtherType and IP packet.

C:

It assumes an unrelated action establishes service recovery. Nothing about “Assume an IP packet contains no Layer 2 envelope on a LAN” demonstrates whether captured Ethernet frames contain the expected EtherType and IP packet.

Question 420

Main campus hardware-service ticket. Field report: A Nexus replacement joins the data-center network with stale code. A colleague proposes: “Install an IOS XE image because both products are Cisco switches.” Which technical assessment is best supported?

  1. The proposal overlooks the reported dependency: NX-OS platforms require validated product-specific software and configuration.
  2. The proposed shortcut is sufficient because change the server bios as the nexus os upgrade.
  3. There is no need to validate the reported dependency once copy an unrelated access-switch config without feature review.
  4. The original problem can be treated as resolved from inventory labels alone, without checking nexus software validation behavior.

Explanation

Correct Answer

A:

The alternative does not address the actual reported dependency. NX-OS platforms require validated product-specific software and configuration. The supported intervention is verify supported nx-os version and feature compatibility before reapplying state; acceptance should show that intended NX-OS release and feature/route health after upgrade.

Incorrect Answers

B:

The proposed step “Change the server BIOS as the Nexus OS upgrade” is not the required mechanism.

C:

It assumes an unrelated action establishes service recovery. Nothing about “Copy an unrelated access-switch config without feature review” demonstrates whether intended NX-OS release and feature/route health after upgrade.

D:

The failure described in the field report requires a functional check that intended NX-OS release and feature/route health after upgrade.

Supporting Cisco Devices for Field Technicians (800-150) Practice Tests