mcAfee Secure Website
exam =5
exam =6

Exam Code: 800-150

Exam Name: Supporting Cisco Devices for Field Technicians

Certification Provider: Cisco

Cisco 800-150 Questions & Answers

Reliable & Actual Study Materials for 800-150 Exam Success

100 Questions & Answers with Testing Engine

"800-150: Supporting Cisco Devices for Field Technicians" Testing Engine covers all the knowledge points of the real Cisco 800-150 exam.

The latest actual 800-150 Questions & Answers from Pass4sure. Everything you need to prepare and get best score at 800-150 exam easily and quickly.

exam =7
Guarantee

Satisfaction Guaranteed

Pass4sure has a remarkable Cisco Candidate Success record. We're confident of our products and provide no hassle product exchange. That's how confident we are!

99.3% Pass Rate
Was: $137.49
Now: $124.99

Cisco 800-150 Practice Test 2

Question 10

Customer branch-site maintenance. Field report: An upgrade fails when the image cannot be fully stored in bootflash. A colleague proposes: “Delete all active boot packages without a rollback plan.” Which technical assessment is best supported?

  1. There is no need to validate the reported dependency once resize the uplink vlan to expand flash memory.
  2. The proposed shortcut is sufficient because change ntp time to increase storage capacity.
  3. The proposal overlooks the reported dependency: A valid image needs sufficient compatible local storage and a safe fallback.
  4. The original problem can be treated as resolved from inventory labels alone, without checking available flash space behavior.

Explanation

Correct Answer

C:

The alternative does not address the actual reported dependency. A valid image needs sufficient compatible local storage and a safe fallback. The supported intervention is check free space and remove only explicitly approved obsolete files; acceptance should show that enough storage exists for the complete image and rollback data.

Incorrect Answers

A:

It assumes an unrelated action establishes service recovery. Nothing about “Resize the uplink VLAN to expand flash memory” demonstrates whether enough storage exists for the complete image and rollback data.

B:

The proposed step “Change NTP time to increase storage capacity” is not the required mechanism.

D:

The failure described in the field report requires a functional check that enough storage exists for the complete image and rollback data.

Question 11

Primary data-center night shift. Field report: An IPv6 endpoint needs the link-layer address of its on-link neighbor. The shift lead must choose a return-to-service note for this ticket. Which handoff is technically adequate?

  1. Apply “Manually create a DNS A record to serve as a Neighbor Advertisement” as a substitute and declare success from shipment receipt alone.
  2. Close after recording “Rely on IPv4 ARP for IPv6 neighbor resolution” without checking that a reachable IPv6 neighbor cache entry for the next-hop address.
  3. Defer service verification after “Disable ICMPv6 and expect discovery to remain fully functional” until the next reported incident.
  4. Perform or retain the approved action: use ipv6 neighbor discovery and verify neighbor state; document evidence that a reachable IPv6 neighbor cache entry for the next-hop address.

Explanation

Correct Answer

D:

This handoff preserves the required corrective action and the verifiable service outcome. IPv6 uses ICMPv6 Neighbor Discovery rather than IPv4 ARP for on-link mapping. Recording that a reachable IPv6 neighbor cache entry for the next-hop address makes the signoff testable.

Incorrect Answers

A:

Delivery paperwork describes logistics, not recovered functionality. “Manually create a DNS A record to serve as a Neighbor Advertisement” leaves the technical requirement and its validation unresolved.

B:

This proposes a different action with no acceptance evidence. “Rely on IPv4 ARP for IPv6 neighbor resolution” cannot replace the validated measure that a reachable IPv6 neighbor cache entry for the next-hop address.

C:

A future incident is not a reasonable acceptance gate for a known problem. “Disable ICMPv6 and expect discovery to remain fully functional” is not evidence that a reachable IPv6 neighbor cache entry for the next-hop address.

Question 12

Headquarters wiring-closet visit. Field report: A field technician cannot log in to a Nexus management console after RMA. Which action is the most defensible first step?

  1. Follow the authorized platform/version-specific NX-OS recovery procedure.
  2. Assume a rack PDU cycle automatically resets administrator credentials.
  3. Delete every storage partition to clear a login prompt.
  4. Use a generic IOS ROMMON recipe without verifying applicability.

Explanation

Correct Answer

A:

Recovery workflows differ across platforms and can affect configuration integrity. The action should lead to evidence that authorized admin access restored without unintended service loss.

Incorrect Answers

B:

Attempting this shortcut is not an adequate substitute for the required action. Recovery workflows differ across platforms and can affect configuration integrity. Post-change evidence is still needed.

C:

That change addresses a different aspect of the environment and leaves this requirement unresolved: a field technician cannot log in to a nexus management console after rma. The relevant control is follow the authorized platform/version-specific nx-os recovery procedure.

D:

This alternative would not solve the reported problem. Recovery workflows differ across platforms and can affect configuration integrity. The field team must instead establish whether authorized admin access restored without unintended service loss.

Question 13

Colocation site RMA handoff. Field report: A Nexus leaf cannot bring up a new high-speed uplink after hardware swap. A colleague proposes: “Assume all optical interfaces negotiate arbitrary rates.” Which technical assessment is best supported?

  1. The proposed shortcut is sufficient because reconfigure dhcp options to correct a fec mismatch.
  2. The proposal overlooks the reported dependency: High-speed links need compatible optics, physical settings and FEC modes.
  3. The original problem can be treated as resolved from inventory labels alone, without checking nexus optic support behavior.
  4. There is no need to validate the reported dependency once use only the chassis power light to prove a high-speed port is operational.

Explanation

Correct Answer

B:

The alternative does not address the actual reported dependency. High-speed links need compatible optics, physical settings and FEC modes. The supported intervention is check module port capabilities, fec and optic interoperability with the peer; acceptance should show that stable target speed, clean counters and bidirectional traffic.

Incorrect Answers

A:

The proposed step “Reconfigure DHCP options to correct a FEC mismatch” is not the required mechanism.

C:

The failure described in the field report requires a functional check that stable target speed, clean counters and bidirectional traffic.

D:

It assumes an unrelated action establishes service recovery. Nothing about “Use only the chassis power light to prove a high-speed port is operational” demonstrates whether stable target speed, clean counters and bidirectional traffic.

Question 14

Remote office replacement window. Field report: An application group receives virtual servers and networks but manages the guest OS. Which action is the most defensible first step?

  1. Treat physical rack elevation drawings as the delivered application service.
  2. Assume hosted hardware makes the guest operating system someone else's responsibility by default.
  3. Identify an IaaS-style service boundary.
  4. Classify it as SaaS solely because management uses a browser.

Explanation

Correct Answer

C:

IaaS exposes compute/network infrastructure while consumers commonly manage their own OS workloads. The action should lead to evidence that the customer is responsible for guest OS configuration and applications.

Incorrect Answers

A:

Attempting this shortcut is not an adequate substitute for the required action. IaaS exposes compute/network infrastructure while consumers commonly manage their own OS workloads. Post-change evidence is still needed.

B:

That change addresses a different aspect of the environment and leaves this requirement unresolved: an application group receives virtual servers and networks but manages the guest os. The relevant control is identify an iaas-style service boundary.

D:

This alternative would not solve the reported problem. IaaS exposes compute/network infrastructure while consumers commonly manage their own OS workloads. The field team must instead establish whether the customer is responsible for guest OS configuration and applications.

Question 15

Disaster-recovery facility inspection. Field report: The spare must match a ticket's PID and serial number. A colleague proposes: “Trust the hostname as the unique chassis serial number.” Which technical assessment is best supported?

  1. The original problem can be treated as resolved from inventory labels alone, without checking show inventory behavior.
  2. There is no need to validate the reported dependency once infer the serial number from the connected vlan id.
  3. The proposed shortcut is sufficient because use the interface description field as manufacturer pid evidence.
  4. The proposal overlooks the reported dependency: Cisco inventory output exposes product and serial identifiers for chassis and FRUs.

Explanation

Correct Answer

D:

The alternative does not address the actual reported dependency. Cisco inventory output exposes product and serial identifiers for chassis and FRUs. The supported intervention is capture `show inventory` and compare to physical and rma labels; acceptance should show that chassis PID, serial and relevant module identities match the replacement ticket.

Incorrect Answers

A:

The failure described in the field report requires a functional check that chassis PID, serial and relevant module identities match the replacement ticket.

B:

It assumes an unrelated action establishes service recovery. Nothing about “Infer the serial number from the connected VLAN ID” demonstrates whether chassis PID, serial and relevant module identities match the replacement ticket.

C:

The proposed step “Use the interface description field as manufacturer PID evidence” is not the required mechanism.

Question 16

Main campus hardware-service ticket. Field report: A line card must be removed from a grounded chassis. Which action is the most defensible first step?

  1. Use approved ESD wrist protection, antistatic handling and required module tools.
  2. Handle exposed connectors with ungrounded wet gloves.
  3. Remove the chassis grounding conductor before touching the module.
  4. Use magnetic metal shavings to clean contacts.

Explanation

Correct Answer

A:

Proper service tools protect sensitive electronics and personnel. The action should lead to evidence that ESD and grounding requirements are met before removal.

Incorrect Answers

B:

This alternative would not solve the reported problem. Proper service tools protect sensitive electronics and personnel. The field team must instead establish whether ESD and grounding requirements are met before removal.

C:

That change addresses a different aspect of the environment and leaves this requirement unresolved: a line card must be removed from a grounded chassis. The relevant control is use approved esd wrist protection, antistatic handling and required module tools.

D:

Attempting this shortcut is not an adequate substitute for the required action. Proper service tools protect sensitive electronics and personnel. Post-change evidence is still needed.

Question 17

Regional north-campus service window. Field report: A Nexus replacement enters boot loader instead of the expected NX-OS prompt. The approved intervention is complete. What observation provides the strongest technical acceptance evidence?

  1. Confirm only that the work ticket says “completed,” without testing nx-os boot image check.
  2. Demonstrate that NX-OS boots the approved release and saves its boot settings.
  3. Confirm the site inventory list still contains the hostname, without validating the reported service.
  4. Confirm only that the technician attempted: install a random ios xe `.bin` image from another hardware family.

Explanation

Correct Answer

B:

NX-OS boots the approved release and saves its boot settings. A valid compatible boot image and boot path are prerequisites for normal NX-OS startup.

Incorrect Answers

A:

Check whether NX-OS boots the approved release and saves its boot settings.

C:

Confirm that NX-OS boots the approved release and saves its boot settings. A valid compatible boot image and boot path are prerequisites for normal NX-OS startup.

D:

For example, “Install a random IOS XE `.bin` image from another hardware family” does not demonstrate the corrected technical state.

Question 18

Customer branch-site maintenance. Field report: A fan module needs replacement in a live modular chassis. The approved intervention is complete. What observation provides the strongest technical acceptance evidence?

  1. Confirm only that the work ticket says “completed,” without testing hot-swap eligibility.
  2. Confirm the site inventory list still contains the hostname, without validating the reported service.
  3. Demonstrate that cooling remains within limits and the new fan is detected healthy.
  4. Confirm only that the technician attempted: pull all cooling modules simultaneously to make room.

Explanation

Correct Answer

C:

Cooling remains within limits and the new fan is detected healthy. Hot-replaceability and allowable removal windows depend on the platform and redundancy state.

Incorrect Answers

A:

Check whether cooling remains within limits and the new fan is detected healthy.

B:

Confirm that cooling remains within limits and the new fan is detected healthy.

D:

For example, “Pull all cooling modules simultaneously to make room” does not demonstrate the corrected technical state.

Question 19

Primary data-center night shift. Field report: A chassis reaches a login prompt after software activation. The approved intervention is complete. What observation provides the strongest technical acceptance evidence?

  1. Confirm only that the technician attempted: assume the new image name guarantees application reachability.
  2. Confirm only that the work ticket says “completed,” without testing post-upgrade validation.
  3. Confirm the site inventory list still contains the hostname, without validating the reported service.
  4. Demonstrate that image release and relevant service acceptance checks.

Explanation

Correct Answer

D:

Image release and relevant service acceptance checks. Boot success alone does not establish the health of network services.

Incorrect Answers

A:

For example, “Assume the new image name guarantees application reachability” does not demonstrate the corrected technical state.

B:

Check whether image release and relevant service acceptance checks. Boot success alone does not establish the health of network services.

C:

Confirm that image release and relevant service acceptance checks. Boot success alone does not establish the health of network services.

Question 20

Headquarters wiring-closet visit. Field report: A desk endpoint must register for enterprise voice calling. The approved intervention is complete. What observation provides the strongest technical acceptance evidence?

  1. Demonstrate that voice VLAN, address assignment and successful call-control registration.
  2. Confirm the site inventory list still contains the hostname, without validating the reported service.
  3. Confirm only that the technician attempted: use an unpowered passive patch panel as a voice server.
  4. Confirm only that the work ticket says “completed,” without testing ip phone identity.

Explanation

Correct Answer

A:

Voice VLAN, address assignment and successful call-control registration. An IP phone is a collaboration endpoint using network services and a calling platform.

Incorrect Answers

B:

Confirm that voice VLAN, address assignment and successful call-control registration.

C:

For example, “Use an unpowered passive patch panel as a voice server” does not demonstrate the corrected technical state.

D:

Check whether voice VLAN, address assignment and successful call-control registration.

Supporting Cisco Devices for Field Technicians (800-150) Practice Tests