mcAfee Secure Website
exam =5
exam =6

Exam Code: NS0-165

Exam Name: NetApp Certified Data Administrator, ONTAP

Certification Provider: Network Appliance

Corresponding Certification: NCDA ONTAP

Network Appliance NS0-165 Questions & Answers

Reliable & Actual Study Materials for NS0-165 Exam Success

60 Questions & Answers with Testing Engine

"NS0-165: NetApp Certified Data Administrator, ONTAP" Testing Engine covers all the knowledge points of the real Network Appliance NS0-165 exam.

The latest actual NS0-165 Questions & Answers from Pass4sure. Everything you need to prepare and get best score at NS0-165 exam easily and quickly.

exam =7
Guarantee

Satisfaction Guaranteed

Pass4sure has a remarkable Network Appliance Candidate Success record. We're confident of our products and provide no hassle product exchange. That's how confident we are!

99.3% Pass Rate
Was: $137.49
Now: $124.99

Network Appliance NS0-165 Practice Test 50

Question 490

A NetApp ONTAP administrator must resolve this situation: An NFSv4 client sees nobody ownership after a directory service change. Select TWO: the targeted corrective action and its strongest verification. (Select TWO.)

  1. Both supported client types access test files with the expected effective permission owner and policy.
  2. Trace SMB client name resolution, share existence, namespace paths and authentication when users report missing mapped drives.
  3. Troubleshoot ONTAP NFS identity resolution, UID and GID mapping and security style before changing volume ownership.
  4. Validate client-to-data-LIF connectivity, SVM namespace junctions and protocol service before restoring unrelated storage objects.
  5. A named user maps consistently to the expected numeric identity and accesses a permitted file through NFS.

Explanation

Correct Answers

C:

This is the proposed corrective action for: An NFSv4 client sees nobody ownership after a directory service change. The action addresses the ONTAP failure mechanism: Inconsistent identities between client and SVM can appear as permission errors even when network mounts succeed.

E:

This provides separate verification for the same issue: An NFSv4 client sees nobody ownership after a directory service change. The outcome tests whether remediation is effective and can be recorded as acceptance evidence.

Incorrect Answers

A:

Both supported client types access test files with the expected effective permission owner and policy. It is not the complementary risk control for nfs name service and uid gid mapping.

B:

Trace SMB client name resolution, share existence, namespace paths and authentication when users report missing mapped drives. This does not supply the required nfs name service and uid gid mapping action-and-control pair.

D:

Validate client-to-data-LIF connectivity, SVM namespace junctions and protocol service before restoring unrelated storage objects. The nfs name service and uid gid mapping implementation and safeguard are still missing.

Question 491

During a storage operations review for an enterprise disaster recovery review, the team observes: A UID collision lets a different user access a shared Linux directory. The decision must maintain preservation of recoverable data under controlled change. What should the storage administrator do first for the stated requirement?

  1. Verify the effective ONTAP volume security style and name mapping when NFS and SMB clients share files.
  2. Troubleshoot ONTAP NFS identity resolution, UID and GID mapping and security style before changing volume ownership.
  3. Validate client-to-data-LIF connectivity, SVM namespace junctions and protocol service before restoring unrelated storage objects.
  4. Trace SMB client name resolution, share existence, namespace paths and authentication when users report missing mapped drives.

Explanation

Correct Answer

B:

This action addresses the reported ONTAP condition: A UID collision lets a different user access a shared Linux directory. It specifically applies nfs name service and uid gid mapping and mitigates: Inconsistent identities between client and SVM can appear as permission errors even when network mounts succeed. A practical completion check is: A named user maps consistently to the expected numeric identity and accesses a permitted file through NFS.

Incorrect Answers

A:

Verify the effective ONTAP volume security style and name mapping when NFS and SMB clients share files. That change would not implement nfs name service and uid gid mapping.

C:

Validate client-to-data-LIF connectivity, SVM namespace junctions and protocol service before restoring unrelated storage objects. The nfs name service and uid gid mapping prerequisite remains unaddressed.

D:

Trace SMB client name resolution, share existence, namespace paths and authentication when users report missing mapped drives. It changes a different feature than nfs name service and uid gid mapping.

Question 492

After corrective work for the ONTAP issue 'A UID collision lets a different user access a shared Linux directory', the operator seeks objective signoff. What observable test should the operator require before closing this issue?

  1. A client mounts or connects to the documented NAS path over the correct LIF with expected read/write rights.
  2. Both supported client types access test files with the expected effective permission owner and policy.
  3. The original UNC or DFS path resolves to the intended server and authorized users access its correct share.
  4. A named user maps consistently to the expected numeric identity and accesses a permitted file through NFS.

Explanation

Correct Answer

D:

This is observable acceptance evidence for: A UID collision lets a different user access a shared Linux directory. It demonstrates the intended ONTAP storage behavior in the relevant situation, rather than merely showing that a configuration field exists.

Incorrect Answers

A:

A client mounts or connects to the documented NAS path over the correct LIF with expected read/write rights. The configuration must instead establish nfs name service and uid gid mapping.

B:

Both supported client types access test files with the expected effective permission owner and policy. The nfs name service and uid gid mapping prerequisite remains unaddressed.

C:

The original UNC or DFS path resolves to the intended server and authorized users access its correct share. It changes a different feature than nfs name service and uid gid mapping.

Question 493

During a storage operations review for a regulated healthcare records provider, the team observes: A UNIX permissions incident persists although the export allows the client subnet. The decision must maintain patient data and application recovery obligations. Which engineering choice most directly solves this problem?

  1. Trace SMB client name resolution, share existence, namespace paths and authentication when users report missing mapped drives.
  2. Troubleshoot ONTAP NFS identity resolution, UID and GID mapping and security style before changing volume ownership.
  3. Validate client-to-data-LIF connectivity, SVM namespace junctions and protocol service before restoring unrelated storage objects.
  4. Verify the effective ONTAP volume security style and name mapping when NFS and SMB clients share files.

Explanation

Correct Answer

B:

This action addresses the reported ONTAP condition: A UNIX permissions incident persists although the export allows the client subnet. It specifically applies nfs name service and uid gid mapping and mitigates: Inconsistent identities between client and SVM can appear as permission errors even when network mounts succeed. A practical completion check is: A named user maps consistently to the expected numeric identity and accesses a permitted file through NFS.

Incorrect Answers

A:

Trace SMB client name resolution, share existence, namespace paths and authentication when users report missing mapped drives. The nfs name service and uid gid mapping prerequisite remains unaddressed.

C:

Validate client-to-data-LIF connectivity, SVM namespace junctions and protocol service before restoring unrelated storage objects. That change would not implement nfs name service and uid gid mapping.

D:

Verify the effective ONTAP volume security style and name mapping when NFS and SMB clients share files. The configuration must instead establish nfs name service and uid gid mapping.

Question 494

After corrective work for the ONTAP issue 'A UNIX permissions incident persists although the export allows the client subnet', the operator seeks objective signoff. Which verification is most relevant to the storage problem described?

  1. A named user maps consistently to the expected numeric identity and accesses a permitted file through NFS.
  2. Both supported client types access test files with the expected effective permission owner and policy.
  3. The original UNC or DFS path resolves to the intended server and authorized users access its correct share.
  4. A client mounts or connects to the documented NAS path over the correct LIF with expected read/write rights.

Explanation

Correct Answer

A:

This is observable acceptance evidence for: A UNIX permissions incident persists although the export allows the client subnet. It demonstrates the intended ONTAP storage behavior in the relevant situation, rather than merely showing that a configuration field exists.

Incorrect Answers

B:

Both supported client types access test files with the expected effective permission owner and policy. That result could pass without demonstrating nfs name service and uid gid mapping.

C:

The original UNC or DFS path resolves to the intended server and authorized users access its correct share. Acceptance here depends on observing nfs name service and uid gid mapping, not only that test.

D:

A client mounts or connects to the documented NAS path over the correct LIF with expected read/write rights. It does not establish the requested nfs name service and uid gid mapping outcome.

Question 495

During a storage operations review for a university research storage team, the team observes: An administrator changes every file owner before verifying identity mapping. The decision must maintain shared-client safety and reproducible workloads. Which change best corrects the storage design under these conditions?

  1. Verify the effective ONTAP volume security style and name mapping when NFS and SMB clients share files.
  2. Troubleshoot ONTAP NFS identity resolution, UID and GID mapping and security style before changing volume ownership.
  3. Trace SMB client name resolution, share existence, namespace paths and authentication when users report missing mapped drives.
  4. Validate client-to-data-LIF connectivity, SVM namespace junctions and protocol service before restoring unrelated storage objects.

Explanation

Correct Answer

B:

This action addresses the reported ONTAP condition: An administrator changes every file owner before verifying identity mapping. It specifically applies nfs name service and uid gid mapping and mitigates: Inconsistent identities between client and SVM can appear as permission errors even when network mounts succeed. A practical completion check is: A named user maps consistently to the expected numeric identity and accesses a permitted file through NFS.

Incorrect Answers

A:

Verify the effective ONTAP volume security style and name mapping when NFS and SMB clients share files. That result could pass without demonstrating nfs name service and uid gid mapping.

C:

Trace SMB client name resolution, share existence, namespace paths and authentication when users report missing mapped drives. It does not establish the requested nfs name service and uid gid mapping outcome.

D:

Validate client-to-data-LIF connectivity, SVM namespace junctions and protocol service before restoring unrelated storage objects. The relevant success criterion is nfs name service and uid gid mapping; this measures a different function.

Question 496

After corrective work for the ONTAP issue 'An administrator changes every file owner before verifying identity mapping', the operator seeks objective signoff. What evidence would show that the corrective configuration is working?

  1. A named user maps consistently to the expected numeric identity and accesses a permitted file through NFS.
  2. A client mounts or connects to the documented NAS path over the correct LIF with expected read/write rights.
  3. Both supported client types access test files with the expected effective permission owner and policy.
  4. The original UNC or DFS path resolves to the intended server and authorized users access its correct share.

Explanation

Correct Answer

A:

This is observable acceptance evidence for: An administrator changes every file owner before verifying identity mapping. It demonstrates the intended ONTAP storage behavior in the relevant situation, rather than merely showing that a configuration field exists.

Incorrect Answers

B:

A client mounts or connects to the documented NAS path over the correct LIF with expected read/write rights. It does not establish the requested nfs name service and uid gid mapping outcome.

C:

Both supported client types access test files with the expected effective permission owner and policy. The relevant success criterion is nfs name service and uid gid mapping; this measures a different function.

D:

The original UNC or DFS path resolves to the intended server and authorized users access its correct share. That result could pass without demonstrating nfs name service and uid gid mapping.

Question 497

During a storage operations review for a regulated healthcare records provider, the team observes: A departmental UNC path fails after a DNS CNAME change. The decision must maintain patient data and application recovery obligations. Which ONTAP administration change best addresses the observed failure?

  1. Validate client-to-data-LIF connectivity, SVM namespace junctions and protocol service before restoring unrelated storage objects.
  2. Trace SMB client name resolution, share existence, namespace paths and authentication when users report missing mapped drives.
  3. Verify the effective ONTAP volume security style and name mapping when NFS and SMB clients share files.
  4. Troubleshoot ONTAP NFS identity resolution, UID and GID mapping and security style before changing volume ownership.

Explanation

Correct Answer

B:

This action addresses the reported ONTAP condition: A departmental UNC path fails after a DNS CNAME change. It specifically applies smb path and dfs name resolution troubleshooting and mitigates: A healthy SMB service and volume do not repair an incorrect DNS alias or missing share path. A practical completion check is: The original UNC or DFS path resolves to the intended server and authorized users access its correct share.

Incorrect Answers

A:

Validate client-to-data-LIF connectivity, SVM namespace junctions and protocol service before restoring unrelated storage objects. The smb path and dfs name resolution troubleshooting prerequisite remains unaddressed.

C:

Verify the effective ONTAP volume security style and name mapping when NFS and SMB clients share files. That change would not implement smb path and dfs name resolution troubleshooting.

D:

Troubleshoot ONTAP NFS identity resolution, UID and GID mapping and security style before changing volume ownership. The configuration must instead establish smb path and dfs name resolution troubleshooting.

Question 498

A NetApp ONTAP change review identifies: A departmental UNC path fails after a DNS CNAME change. Which consequence should the administrator prioritize in this situation?

  1. Inconsistent identities between client and SVM can appear as permission errors even when network mounts succeed.
  2. A healthy SMB service and volume do not repair an incorrect DNS alias or missing share path.
  3. Security style defines permission semantics rather than banning one protocol; poor mapping can cause unexpected authorization results.
  4. A healthy aggregate cannot expose a NAS path if DNS, routing or namespace placement is wrong.

Explanation

Correct Answer

B:

This is the directly implicated exposure when a departmental UNC path fails after a DNS CNAME change. The relevant corrective control is: Trace SMB client name resolution, share existence, namespace paths and authentication when users report missing mapped drives. A meaningful acceptance test is: The original UNC or DFS path resolves to the intended server and authorized users access its correct share.

Incorrect Answers

A:

Inconsistent identities between client and SVM can appear as permission errors even when network mounts succeed. It changes a different feature than smb path and dfs name resolution troubleshooting.

C:

Security style defines permission semantics rather than banning one protocol; poor mapping can cause unexpected authorization results. The configuration must instead establish smb path and dfs name resolution troubleshooting.

D:

A healthy aggregate cannot expose a NAS path if DNS, routing or namespace placement is wrong. The smb path and dfs name resolution troubleshooting prerequisite remains unaddressed.

Question 499

During a storage operations review for a university research storage team, the team observes: An SMB share was renamed but mapped-drive policies still use the former name. The decision must maintain shared-client safety and reproducible workloads. What should the storage administrator do first for the stated requirement?

  1. Validate client-to-data-LIF connectivity, SVM namespace junctions and protocol service before restoring unrelated storage objects.
  2. Trace SMB client name resolution, share existence, namespace paths and authentication when users report missing mapped drives.
  3. Verify the effective ONTAP volume security style and name mapping when NFS and SMB clients share files.
  4. Troubleshoot ONTAP NFS identity resolution, UID and GID mapping and security style before changing volume ownership.

Explanation

Correct Answer

B:

This action addresses the reported ONTAP condition: An SMB share was renamed but mapped-drive policies still use the former name. It specifically applies smb path and dfs name resolution troubleshooting and mitigates: A healthy SMB service and volume do not repair an incorrect DNS alias or missing share path. A practical completion check is: The original UNC or DFS path resolves to the intended server and authorized users access its correct share.

Incorrect Answers

A:

Validate client-to-data-LIF connectivity, SVM namespace junctions and protocol service before restoring unrelated storage objects. That change would not implement smb path and dfs name resolution troubleshooting.

C:

Verify the effective ONTAP volume security style and name mapping when NFS and SMB clients share files. The smb path and dfs name resolution troubleshooting prerequisite remains unaddressed.

D:

Troubleshoot ONTAP NFS identity resolution, UID and GID mapping and security style before changing volume ownership. It changes a different feature than smb path and dfs name resolution troubleshooting.

Question 500

A NetApp ONTAP administrator must resolve this situation: An SMB share was renamed but mapped-drive policies still use the former name. Which TWO choices form a defensible remediation-and-acceptance pair? (Select TWO.)

  1. Troubleshoot ONTAP NFS identity resolution, UID and GID mapping and security style before changing volume ownership.
  2. Trace SMB client name resolution, share existence, namespace paths and authentication when users report missing mapped drives.
  3. Verify the effective ONTAP volume security style and name mapping when NFS and SMB clients share files.
  4. A client mounts or connects to the documented NAS path over the correct LIF with expected read/write rights.
  5. The original UNC or DFS path resolves to the intended server and authorized users access its correct share.

Explanation

Correct Answers

B:

This is the proposed corrective action for: An SMB share was renamed but mapped-drive policies still use the former name. The action addresses the ONTAP failure mechanism: A healthy SMB service and volume do not repair an incorrect DNS alias or missing share path.

E:

This provides separate verification for the same issue: An SMB share was renamed but mapped-drive policies still use the former name. The outcome tests whether remediation is effective and can be recorded as acceptance evidence.

Incorrect Answers

A:

Troubleshoot ONTAP NFS identity resolution, UID and GID mapping and security style before changing volume ownership. The paired controls concern smb path and dfs name resolution troubleshooting, not that measure.

C:

Verify the effective ONTAP volume security style and name mapping when NFS and SMB clients share files. It is not the complementary risk control for smb path and dfs name resolution troubleshooting.

D:

A client mounts or connects to the documented NAS path over the correct LIF with expected read/write rights. This does not supply the required smb path and dfs name resolution troubleshooting action-and-control pair.

NetApp Certified Data Administrator, ONTAP (NS0-165) Practice Tests