mcAfee Secure Website
exam =5
exam =6

Exam Code: NS0-165

Exam Name: NetApp Certified Data Administrator, ONTAP

Certification Provider: Network Appliance

Corresponding Certification: NCDA ONTAP

Network Appliance NS0-165 Questions & Answers

Reliable & Actual Study Materials for NS0-165 Exam Success

60 Questions & Answers with Testing Engine

"NS0-165: NetApp Certified Data Administrator, ONTAP" Testing Engine covers all the knowledge points of the real Network Appliance NS0-165 exam.

The latest actual NS0-165 Questions & Answers from Pass4sure. Everything you need to prepare and get best score at NS0-165 exam easily and quickly.

exam =7
Guarantee

Satisfaction Guaranteed

Pass4sure has a remarkable Network Appliance Candidate Success record. We're confident of our products and provide no hassle product exchange. That's how confident we are!

99.3% Pass Rate
Was: $137.49
Now: $124.99

Network Appliance NS0-165 Practice Test 1

Question 1

During a storage operations review for a regulated healthcare records provider, the team observes: An archival file workload is moved to an all-flash design without cost justification. The decision must maintain patient data and application recovery obligations. Which ONTAP administration change best addresses the observed failure?

  1. Validate controller pairings, shelf paths, disk ownership and hardware redundancy as a coherent ONTAP HA design.
  2. Select an AFF configuration for latency-sensitive all-flash ONTAP workloads after assessing SSD capacity, network and application demand.
  3. Assess FAS disk economics and the mixed performance profile against workload IOPS and retention before sizing the ONTAP platform.
  4. Confirm aggregate disk ownership, pool and spare availability before replacing failed media or expanding physical storage.

Explanation

Correct Answer

C:

This action addresses the reported ONTAP condition: An archival file workload is moved to an all-flash design without cost justification. It specifically applies FAS hybrid capacity platform selection and mitigates: Choosing a capacity-oriented configuration solely by usable terabytes can leave random-read latency outside the SLA. A practical completion check is: A measured mixed-workload test meets latency and capacity headroom targets on the chosen FAS configuration.

Incorrect Answers

A:

Validate controller pairings, shelf paths, disk ownership and hardware redundancy as a coherent ONTAP HA design. The FAS hybrid capacity platform selection prerequisite remains unaddressed.

B:

Select an AFF configuration for latency-sensitive all-flash ONTAP workloads after assessing SSD capacity, network and application demand. It changes a different feature than FAS hybrid capacity platform selection.

D:

Confirm aggregate disk ownership, pool and spare availability before replacing failed media or expanding physical storage. The configuration must instead establish FAS hybrid capacity platform selection.

Question 2

After corrective work for the ONTAP issue 'An archival file workload is moved to an all-flash design without cost justification', the operator seeks objective signoff. Which acceptance result demonstrates that this ONTAP issue has been corrected?

  1. End-to-end workload testing measures client latency, flash capacity and network bottlenecks before acceptance.
  2. Disk and spare inventories identify the correct owners and sufficient compatible media for the planned recovery.
  3. A measured mixed-workload test meets latency and capacity headroom targets on the chosen FAS configuration.
  4. A planned single-component failure retains the required data availability and shows expected surviving shelf paths.

Explanation

Correct Answer

C:

This is observable acceptance evidence for: An archival file workload is moved to an all-flash design without cost justification. It demonstrates the intended ONTAP storage behavior in the relevant situation, rather than merely showing that a configuration field exists.

Incorrect Answers

A:

End-to-end workload testing measures client latency, flash capacity and network bottlenecks before acceptance. The relevant success criterion is FAS hybrid capacity platform selection; this measures a different function.

B:

Disk and spare inventories identify the correct owners and sufficient compatible media for the planned recovery. That result could pass without demonstrating FAS hybrid capacity platform selection.

D:

A planned single-component failure retains the required data availability and shows expected surviving shelf paths. It does not establish the requested FAS hybrid capacity platform selection outcome.

Question 3

During a storage operations review for a university research storage team, the team observes: A capacity proposal budgets drive size but omits random read latency. The decision must maintain shared-client safety and reproducible workloads. What should the storage administrator do first for the stated requirement?

  1. Evaluate an ASA or supported ASA r2 design for block-oriented workloads using the platform-specific SAN management and availability model.
  2. Assess FAS disk economics and the mixed performance profile against workload IOPS and retention before sizing the ONTAP platform.
  3. Confirm aggregate disk ownership, pool and spare availability before replacing failed media or expanding physical storage.
  4. Validate controller pairings, shelf paths, disk ownership and hardware redundancy as a coherent ONTAP HA design.

Explanation

Correct Answer

B:

This action addresses the reported ONTAP condition: A capacity proposal budgets drive size but omits random read latency. It specifically applies FAS hybrid capacity platform selection and mitigates: Choosing a capacity-oriented configuration solely by usable terabytes can leave random-read latency outside the SLA. A practical completion check is: A measured mixed-workload test meets latency and capacity headroom targets on the chosen FAS configuration.

Incorrect Answers

A:

Evaluate an ASA or supported ASA r2 design for block-oriented workloads using the platform-specific SAN management and availability model. That change would not implement FAS hybrid capacity platform selection.

C:

Confirm aggregate disk ownership, pool and spare availability before replacing failed media or expanding physical storage. The FAS hybrid capacity platform selection prerequisite remains unaddressed.

D:

Validate controller pairings, shelf paths, disk ownership and hardware redundancy as a coherent ONTAP HA design. It changes a different feature than FAS hybrid capacity platform selection.

Question 4

After corrective work for the ONTAP issue 'A capacity proposal budgets drive size but omits random read latency', the operator seeks objective signoff. What observable test should the operator require before closing this issue?

  1. A supported host accesses a newly provisioned block device along redundant paths under a planned controller disruption.
  2. Disk and spare inventories identify the correct owners and sufficient compatible media for the planned recovery.
  3. A measured mixed-workload test meets latency and capacity headroom targets on the chosen FAS configuration.
  4. A planned single-component failure retains the required data availability and shows expected surviving shelf paths.

Explanation

Correct Answer

C:

This is observable acceptance evidence for: A capacity proposal budgets drive size but omits random read latency. It demonstrates the intended ONTAP storage behavior in the relevant situation, rather than merely showing that a configuration field exists.

Incorrect Answers

A:

A supported host accesses a newly provisioned block device along redundant paths under a planned controller disruption. The configuration must instead establish FAS hybrid capacity platform selection.

B:

Disk and spare inventories identify the correct owners and sufficient compatible media for the planned recovery. The FAS hybrid capacity platform selection prerequisite remains unaddressed.

D:

A planned single-component failure retains the required data availability and shows expected surviving shelf paths. That change would not implement FAS hybrid capacity platform selection.

Question 5

During a storage operations review for a regional managed storage service provider, the team observes: A small transactional database shares a shelf planned for cold files. The decision must maintain tenant boundaries and documented service commitments. Which engineering choice most directly solves this problem?

  1. Validate controller pairings, shelf paths, disk ownership and hardware redundancy as a coherent ONTAP HA design.
  2. Assess FAS disk economics and the mixed performance profile against workload IOPS and retention before sizing the ONTAP platform.
  3. Select an AFF configuration for latency-sensitive all-flash ONTAP workloads after assessing SSD capacity, network and application demand.
  4. Confirm aggregate disk ownership, pool and spare availability before replacing failed media or expanding physical storage.

Explanation

Correct Answer

B:

This action addresses the reported ONTAP condition: A small transactional database shares a shelf planned for cold files. It specifically applies FAS hybrid capacity platform selection and mitigates: Choosing a capacity-oriented configuration solely by usable terabytes can leave random-read latency outside the SLA. A practical completion check is: A measured mixed-workload test meets latency and capacity headroom targets on the chosen FAS configuration.

Incorrect Answers

A:

Validate controller pairings, shelf paths, disk ownership and hardware redundancy as a coherent ONTAP HA design. The FAS hybrid capacity platform selection prerequisite remains unaddressed.

C:

Select an AFF configuration for latency-sensitive all-flash ONTAP workloads after assessing SSD capacity, network and application demand. That change would not implement FAS hybrid capacity platform selection.

D:

Confirm aggregate disk ownership, pool and spare availability before replacing failed media or expanding physical storage. The configuration must instead establish FAS hybrid capacity platform selection.

Question 6

After corrective work for the ONTAP issue 'A small transactional database shares a shelf planned for cold files', the operator seeks objective signoff. Which verification is most relevant to the storage problem described?

  1. A measured mixed-workload test meets latency and capacity headroom targets on the chosen FAS configuration.
  2. End-to-end workload testing measures client latency, flash capacity and network bottlenecks before acceptance.
  3. Disk and spare inventories identify the correct owners and sufficient compatible media for the planned recovery.
  4. A planned single-component failure retains the required data availability and shows expected surviving shelf paths.

Explanation

Correct Answer

A:

This is observable acceptance evidence for: A small transactional database shares a shelf planned for cold files. It demonstrates the intended ONTAP storage behavior in the relevant situation, rather than merely showing that a configuration field exists.

Incorrect Answers

B:

End-to-end workload testing measures client latency, flash capacity and network bottlenecks before acceptance. That result could pass without demonstrating FAS hybrid capacity platform selection.

C:

Disk and spare inventories identify the correct owners and sufficient compatible media for the planned recovery. Acceptance here depends on observing FAS hybrid capacity platform selection, not only that test.

D:

A planned single-component failure retains the required data availability and shows expected surviving shelf paths. It does not establish the requested FAS hybrid capacity platform selection outcome.

Question 7

During a storage operations review for an enterprise disaster recovery review, the team observes: Procurement compares only raw disk terabytes rather than workload requirements. The decision must maintain preservation of recoverable data under controlled change. Which change best corrects the storage design under these conditions?

  1. Assess FAS disk economics and the mixed performance profile against workload IOPS and retention before sizing the ONTAP platform.
  2. Select an AFF configuration for latency-sensitive all-flash ONTAP workloads after assessing SSD capacity, network and application demand.
  3. Evaluate an ASA or supported ASA r2 design for block-oriented workloads using the platform-specific SAN management and availability model.
  4. Confirm aggregate disk ownership, pool and spare availability before replacing failed media or expanding physical storage.

Explanation

Correct Answer

A:

This action addresses the reported ONTAP condition: Procurement compares only raw disk terabytes rather than workload requirements. It specifically applies FAS hybrid capacity platform selection and mitigates: Choosing a capacity-oriented configuration solely by usable terabytes can leave random-read latency outside the SLA. A practical completion check is: A measured mixed-workload test meets latency and capacity headroom targets on the chosen FAS configuration.

Incorrect Answers

B:

Select an AFF configuration for latency-sensitive all-flash ONTAP workloads after assessing SSD capacity, network and application demand. The configuration must instead establish FAS hybrid capacity platform selection.

C:

Evaluate an ASA or supported ASA r2 design for block-oriented workloads using the platform-specific SAN management and availability model. The FAS hybrid capacity platform selection prerequisite remains unaddressed.

D:

Confirm aggregate disk ownership, pool and spare availability before replacing failed media or expanding physical storage. It changes a different feature than FAS hybrid capacity platform selection.

Question 8

A NetApp ONTAP change review identifies: Procurement compares only raw disk terabytes rather than workload requirements. Which unresolved risk most directly follows from the observed condition?

  1. Insufficient compatible spares can delay reconstruction and leave aggregates exposed after a drive failure.
  2. A fast storage controller does not overcome an overloaded host path or an undersized data network.
  3. Assuming all ONTAP platforms expose identical provisioning and HA semantics can lead to an unsupported storage design.
  4. Choosing a capacity-oriented configuration solely by usable terabytes can leave random-read latency outside the SLA.

Explanation

Correct Answer

D:

This is the directly implicated exposure when procurement compares only raw disk terabytes rather than workload requirements. The relevant corrective control is: Assess FAS disk economics and the mixed performance profile against workload IOPS and retention before sizing the ONTAP platform. A meaningful acceptance test is: A measured mixed-workload test meets latency and capacity headroom targets on the chosen FAS configuration.

Incorrect Answers

A:

Insufficient compatible spares can delay reconstruction and leave aggregates exposed after a drive failure. Recurrence here depends on FAS hybrid capacity platform selection, not this safeguard.

B:

A fast storage controller does not overcome an overloaded host path or an undersized data network. That protection can exist while FAS hybrid capacity platform selection is still missing.

C:

Assuming all ONTAP platforms expose identical provisioning and HA semantics can lead to an unsupported storage design. It protects a different risk than the FAS hybrid capacity platform selection requirement.

Question 9

During a storage operations review for a regional managed storage service provider, the team observes: A dense VM estate experiences high disk response time under a hybrid-capacity plan. The decision must maintain tenant boundaries and documented service commitments. Which ONTAP administration change best addresses the observed failure?

  1. Confirm aggregate disk ownership, pool and spare availability before replacing failed media or expanding physical storage.
  2. Validate controller pairings, shelf paths, disk ownership and hardware redundancy as a coherent ONTAP HA design.
  3. Select an AFF configuration for latency-sensitive all-flash ONTAP workloads after assessing SSD capacity, network and application demand.
  4. Evaluate an ASA or supported ASA r2 design for block-oriented workloads using the platform-specific SAN management and availability model.

Explanation

Correct Answer

C:

This action addresses the reported ONTAP condition: A dense VM estate experiences high disk response time under a hybrid-capacity plan. It specifically applies aff flash performance and efficiency placement and mitigates: A fast storage controller does not overcome an overloaded host path or an undersized data network. A practical completion check is: End-to-end workload testing measures client latency, flash capacity and network bottlenecks before acceptance.

Incorrect Answers

A:

Confirm aggregate disk ownership, pool and spare availability before replacing failed media or expanding physical storage. The aff flash performance and efficiency placement prerequisite remains unaddressed.

B:

Validate controller pairings, shelf paths, disk ownership and hardware redundancy as a coherent ONTAP HA design. It changes a different feature than aff flash performance and efficiency placement.

D:

Evaluate an ASA or supported ASA r2 design for block-oriented workloads using the platform-specific SAN management and availability model. The configuration must instead establish aff flash performance and efficiency placement.

Question 10

A NetApp ONTAP administrator must resolve this situation: A dense VM estate experiences high disk response time under a hybrid-capacity plan. Select TWO: the targeted corrective action and its strongest verification. (Select TWO.)

  1. Validate controller pairings, shelf paths, disk ownership and hardware redundancy as a coherent ONTAP HA design.
  2. Confirm aggregate disk ownership, pool and spare availability before replacing failed media or expanding physical storage.
  3. A supported host accesses a newly provisioned block device along redundant paths under a planned controller disruption.
  4. Select an AFF configuration for latency-sensitive all-flash ONTAP workloads after assessing SSD capacity, network and application demand.
  5. End-to-end workload testing measures client latency, flash capacity and network bottlenecks before acceptance.

Explanation

Correct Answers

D:

This is the proposed corrective action for: A dense VM estate experiences high disk response time under a hybrid-capacity plan. The action addresses the ONTAP failure mechanism: A fast storage controller does not overcome an overloaded host path or an undersized data network.

E:

This provides separate verification for the same issue: A dense VM estate experiences high disk response time under a hybrid-capacity plan. The outcome tests whether remediation is effective and can be recorded as acceptance evidence.

Incorrect Answers

A:

Validate controller pairings, shelf paths, disk ownership and hardware redundancy as a coherent ONTAP HA design. It is not the complementary risk control for aff flash performance and efficiency placement.

B:

Confirm aggregate disk ownership, pool and spare availability before replacing failed media or expanding physical storage. This does not supply the required aff flash performance and efficiency placement action-and-control pair.

C:

A supported host accesses a newly provisioned block device along redundant paths under a planned controller disruption. The paired controls concern aff flash performance and efficiency placement, not that measure.

NetApp Certified Data Administrator, ONTAP (NS0-165) Practice Tests