Question 300
The AI infrastructure team reports: NCCL multi-node performance is good within one rack but drops sharply whenever a second rack joins the collective. What is the most defensible corrective step?
Explanation
Correct Answer
The appropriate intervention is Isolate rack-to-rack switch and transceiver paths using NCCL scaling tests and per-port telemetry. The defining technical dependency is that A cross-rack-only regression points to an external fabric segment or congestion condition. Validate the correction by confirming that A staged 1-rack and 2-rack NCCL comparison identifies and repairs the bottleneck.
Incorrect Answers
For this finding, Verify NCCL interface selection, HCA visibility and transport settings for comparable runs is less direct than Isolate rack-to-rack switch and transceiver paths using NCCL scaling tests and per-port telemetry, because A cross-rack-only regression points to an external fabric segment or congestion condition.
The suggested action targets another problem where CPU TCP throughput does not establish GPU communication performance or RDMA configuration. It does not directly address this case, which needs Isolate rack-to-rack switch and transceiver paths using NCCL scaling tests and per-port telemetry.
This alternative addresses the separate case “A link layer reports no packet drops but NCCL performance degrades during simultaneous jobs on neighboring GPU partitions”. Therefore Inspect fabric congestion and PFC/ECN-related counters with workload concurrency during collective tests. The deciding requirement here is “Isolate rack-to-rack switch and transceiver paths using NCCL scaling tests and per-port telemetry”.