Question 420
During a shared-cluster operating review at a university HPC center, engineers report the following issue: A proposed cluster blocks an emergency access aisle after cable trays are added. The affected work supports research training and scheduled compute allocations; fair resource access and repeatable cluster operations matter. Select TWO: the most appropriate action and the strongest verification of that action. (Select TWO.)
Explanation
Correct Answers
Correct corrective action. Validate rack weight, floor loading, equipment dimensions, service clearances and safe handling procedures before installing dense accelerator systems. This fits the specific reported issue: A proposed cluster blocks an emergency access aisle after cable trays are added. The corresponding failure being reduced is: High-density hardware can exceed structural or access limits even when logical network and power plans appear sufficient.
Correct independent evidence. Facilities approve actual floor loading, cabinet clearances and installation handling requirements for the proposed system. This verifies the corrective approach for the affected research training and scheduled compute allocations instead of treating an architecture diagram alone as success.
Incorrect Answers
Not the most direct the action-and-evidence pair for these facts. Associate a BlueField DPU with offloading selected networking, storage and security infrastructure work from host CPUs while meeting supported deployment constraints. This choice concerns bluefield dpu infrastructure offload and may be valid in another design. But this case reports 'A proposed cluster blocks an emergency access aisle after cable trays are added', which calls for reasoning about rack floor loading and physical space readiness. The targeted response is: Validate rack weight, floor loading, equipment dimensions, service clearances and safe handling procedures before installing dense accelerator systems.
Not the most direct the action-and-evidence pair for these facts. Validate independent power distribution, cooling support, cabling paths and maintenance arrangements against the desired service availability and failure domains. This choice concerns redundant facility services for ai availability and may be valid in another design. But this case reports 'A proposed cluster blocks an emergency access aisle after cable trays are added', which calls for reasoning about rack floor loading and physical space readiness. The targeted response is: Validate rack weight, floor loading, equipment dimensions, service clearances and safe handling procedures before installing dense accelerator systems.
Not the most direct the action-and-evidence pair for these facts. An end-to-end cost and capacity study covers representative utilization, deployment lead time, data movement and required service levels. This choice concerns cloud elasticity versus on-prem capacity tradeoffs and may be valid in another design. But this case reports 'A proposed cluster blocks an emergency access aisle after cable trays are added', which calls for reasoning about rack floor loading and physical space readiness. The targeted response is: Validate rack weight, floor loading, equipment dimensions, service clearances and safe handling procedures before installing dense accelerator systems.