Question 560
The HPE AOS-CX switching case is: A 10G uplink cannot carry expected workloads because one end negotiated at a lower supported rate after optics replacement. Select TWO: a corrective switching action and separate evidence that the correction worked. (Select TWO.)
Explanation
Correct Answers
The targeted correction for A 10G uplink cannot carry expected workloads because one end negotiated at a lower supported rate after optics replacement is: Separate physical CRC errors, output discards and sustained utilization to identify whether throughput is limited by cabling or queue congestion. It reduces the risk that increasing port speed or QoS priority without locating error and drop counters can waste capacity and worsen packet loss.
A separate operational validation for A 10G uplink cannot carry expected workloads because one end negotiated at a lower supported rate after optics replacement is: A controlled traffic test identifies the causal counter and demonstrates improved delivery after the targeted fix. It proves intended behavior instead of accepting configuration presence alone.
Incorrect Answers
This alternative concerns qos misclassification and queue starvation; its associated risk is: An incorrect high-priority class can starve the intended protected service during busy periods. The observed case A 10G uplink cannot carry expected workloads because one end negotiated at a lower supported rate after optics replacement requires the more specific interface errors congestion and bandwidth root cause control. The targeted action is: Separate physical CRC errors, output discards and sustained utilization to identify whether throughput is limited by cabling or queue congestion.
This alternative concerns duplex mismatch negotiation and retransmissions; its associated risk is: A speed or duplex mismatch can cause errors and poor throughput although packets intermittently pass. The observed case A 10G uplink cannot carry expected workloads because one end negotiated at a lower supported rate after optics replacement requires the more specific interface errors congestion and bandwidth root cause control. The targeted action is: Separate physical CRC errors, output discards and sustained utilization to identify whether throughput is limited by cabling or queue congestion.
This alternative concerns spanning-tree convergence and topology-change churn; its associated risk is: Repeated topology changes can interrupt latency-sensitive services even if average switch CPU and link utilization are normal. The observed case A 10G uplink cannot carry expected workloads because one end negotiated at a lower supported rate after optics replacement requires the more specific interface errors congestion and bandwidth root cause control. The targeted action is: Separate physical CRC errors, output discards and sustained utilization to identify whether throughput is limited by cabling or queue congestion.