mcAfee Secure Website
exam =5
exam =6

Exam Code: NSE5_FSW_AD-7.6

Exam Name: Fortinet NSE 5 - FortiSwitch 7.6 Administrator

Certification Provider: Fortinet

Corresponding Certification: NSE5

Fortinet NSE5_FSW_AD-7.6 Questions & Answers

Reliable & Actual Study Materials for NSE5_FSW_AD-7.6 Exam Success

64 Questions & Answers with Testing Engine

"NSE5_FSW_AD-7.6: Fortinet NSE 5 - FortiSwitch 7.6 Administrator" Testing Engine covers all the knowledge points of the real Fortinet NSE5_FSW_AD-7.6 exam.

The latest actual NSE5_FSW_AD-7.6 Questions & Answers from Pass4sure. Everything you need to prepare and get best score at NSE5_FSW_AD-7.6 exam easily and quickly.

exam =7
Guarantee

Satisfaction Guaranteed

Pass4sure has a remarkable Fortinet Candidate Success record. We're confident of our products and provide no hassle product exchange. That's how confident we are!

99.3% Pass Rate
Was: $137.49
Now: $124.99

Fortinet NSE5_FSW_AD-7.6 Practice Test 44

Question 430

An operations team investigates this FortiSwitch 7.6 situation: A switch authenticates endpoint identity inconsistently because its RADIUS reachability is not verified. Select TWO complementary measures: the corrective action AND evidence that it worked.

  1. Use MAC authentication bypass with managed RADIUS identity records for devices unable to speak 802.1X.
  2. Configure supported per-port MAC learning limits or violation behavior to constrain unexpected endpoint fanout.
  3. Enforce 802.1X on suitable access ports with a reachable RADIUS service and configured authorized user groups.
  4. An authorized supplicant completes EAP and receives the specified access policy while unauthorized clients are denied.
  5. An authenticated user receives the expected VLAN and subnet while a different identity is placed in a different approved VLAN.

Explanation

Correct Answer

C:

For the observed condition (A switch authenticates endpoint identity inconsistently because its RADIUS reachability is not verified), the appropriate response is to enforce 802.1X on suitable access ports with a reachable RADIUS service and configured authorized user groups. The underlying risk is that enabling 802.1X without a reachable authentication service can deny all intended clients. This action is targeted to 802.1x access authentication rather than to a different switching feature. Confirm it by checking that an authorized supplicant completes EAP and receives the specified access policy while unauthorized clients are denied.

D:

The relevant acceptance proof for this incident (A switch authenticates endpoint identity inconsistently because its RADIUS reachability is not verified) is: An authorized supplicant completes EAP and receives the specified access policy while unauthorized clients are denied. That observation tests the same failure path that prompted the change, not merely whether a physical link is up. It also helps rule out the known alternative risk: Enabling 802.1X without a reachable authentication service can deny all intended clients. Retain the documented evidence after applying the associated correction: Enforce 802.1X on suitable access ports with a reachable RADIUS service and configured authorized user groups.

Incorrect Answers

A:

Mac authentication bypass for headless devices addresses another technical failure: turning off authentication globally to accommodate one printer exposes the entire access segment. The case states: A switch authenticates endpoint identity inconsistently because its RADIUS reachability is not verified. The most direct paired action and test is: enforce 802.1X on suitable access ports with a reachable RADIUS service and configured authorized user groups.

B:

Learned mac limit on access port addresses another technical failure: an unrestricted access port can become an unmanaged mini-switch attachment point without detection. This choice can be useful for that problem, but it does not establish the 802.1x access authentication control being assessed here.

E:

Radius dynamic VLAN assignment would demonstrate or implement: An authenticated user receives the expected VLAN and subnet while a different identity is placed in a different approved VLAN. The paired-answer requirement concerns 802.1x access authentication; this alternative does not provide the matching intervention and separate acceptance evidence.

Question 431

At a FortiSwitchOS/FortiOS 7.6 network site, an engineer observes: A network printer cannot run an EAP supplicant but requires policy-controlled wired access. Which change MOST DIRECTLY addresses this problem without weakening the intended network design?

  1. Use MAC authentication bypass with managed RADIUS identity records for devices unable to speak 802.1X.
  2. Enforce 802.1X on suitable access ports with a reachable RADIUS service and configured authorized user groups.
  3. Configure supported per-port MAC learning limits or violation behavior to constrain unexpected endpoint fanout.
  4. Use supported RADIUS authorization attributes to place authenticated endpoints into the correct dynamic VLAN.

Explanation

Correct Answer

A:

For the observed condition (A network printer cannot run an EAP supplicant but requires policy-controlled wired access), the appropriate response is to use MAC authentication bypass with managed RADIUS identity records for devices unable to speak 802.1X. The underlying risk is that turning off authentication globally to accommodate one printer exposes the entire access segment. This action is targeted to mac authentication bypass for headless devices rather than to a different switching feature. Confirm it by checking that a registered non-802.1X device is authorized under MAB while unknown MAC identities receive restricted or no access.

Incorrect Answers

B:

802.1x access authentication addresses another technical failure: enabling 802.1X without a reachable authentication service can deny all intended clients. This choice can be useful for that problem, but it does not establish the Mac authentication bypass for headless devices control being assessed here.

C:

Learned mac limit on access port addresses another technical failure: an unrestricted access port can become an unmanaged mini-switch attachment point without detection. This case instead tests Mac authentication bypass for headless devices; the choice measures or changes another part of the system.

D:

Radius dynamic VLAN assignment addresses another technical failure: authenticating a device does not guarantee it lands in the intended security segment when VLAN authorization is missing. The required corrective action concerns Mac authentication bypass for headless devices; a passing result for this alternative could leave that requirement unresolved.

Question 432

After diagnosing the FortiSwitch 7.6 issue, the engineer records: A network printer cannot run an EAP supplicant but requires policy-controlled wired access. Which acceptance evidence MOST DIRECTLY demonstrates the specific correction succeeded?

  1. An authorized supplicant completes EAP and receives the specified access policy while unauthorized clients are denied.
  2. The configured threshold is enforced and violation logs identify a port that exceeds expected MAC learning.
  3. An authenticated user receives the expected VLAN and subnet while a different identity is placed in a different approved VLAN.
  4. A registered non-802.1X device is authorized under MAB while unknown MAC identities receive restricted or no access.

Explanation

Correct Answer

D:

The relevant acceptance proof for this incident (A network printer cannot run an EAP supplicant but requires policy-controlled wired access) is: A registered non-802.1X device is authorized under MAB while unknown MAC identities receive restricted or no access. That observation tests the same failure path that prompted the change, not merely whether a physical link is up. It also helps rule out the known alternative risk: Turning off authentication globally to accommodate one printer exposes the entire access segment. Retain the documented evidence after applying the associated correction: Use MAC authentication bypass with managed RADIUS identity records for devices unable to speak 802.1X.

Incorrect Answers

A:

802.1x access authentication would demonstrate or implement: An authorized supplicant completes EAP and receives the specified access policy while unauthorized clients are denied. The case states: A network printer cannot run an EAP supplicant but requires policy-controlled wired access. The most direct evidence is: A registered non-802.1X device is authorized under MAB while unknown MAC identities receive restricted or no access.

B:

Learned mac limit on access port would demonstrate or implement: The configured threshold is enforced and violation logs identify a port that exceeds expected MAC learning. This choice can be useful for that problem, but it does not establish the Mac authentication bypass for headless devices control being assessed here.

C:

Radius dynamic VLAN assignment would demonstrate or implement: An authenticated user receives the expected VLAN and subnet while a different identity is placed in a different approved VLAN. This case instead tests Mac authentication bypass for headless devices; the choice measures or changes another part of the system.

Question 433

At a FortiSwitchOS/FortiOS 7.6 network site, an engineer observes: A security camera cannot perform 802.1X and is rejected on an otherwise secured switch port. Which change MOST DIRECTLY addresses this problem without weakening the intended network design?

  1. Configure supported per-port MAC learning limits or violation behavior to constrain unexpected endpoint fanout.
  2. Use supported RADIUS authorization attributes to place authenticated endpoints into the correct dynamic VLAN.
  3. Configure a restricted guest or authentication-failure VLAN according to the desired denial and remediation policy.
  4. Use MAC authentication bypass with managed RADIUS identity records for devices unable to speak 802.1X.

Explanation

Correct Answer

D:

For the observed condition (A security camera cannot perform 802.1X and is rejected on an otherwise secured switch port), the appropriate response is to use MAC authentication bypass with managed RADIUS identity records for devices unable to speak 802.1X. The underlying risk is that turning off authentication globally to accommodate one printer exposes the entire access segment. This action is targeted to mac authentication bypass for headless devices rather than to a different switching feature. Confirm it by checking that a registered non-802.1X device is authorized under MAB while unknown MAC identities receive restricted or no access.

Incorrect Answers

A:

Learned mac limit on access port addresses another technical failure: an unrestricted access port can become an unmanaged mini-switch attachment point without detection. The case states: A security camera cannot perform 802.1X and is rejected on an otherwise secured switch port. The most direct corrective action is: use MAC authentication bypass with managed RADIUS identity records for devices unable to speak 802.1X.

B:

Radius dynamic VLAN assignment addresses another technical failure: authenticating a device does not guarantee it lands in the intended security segment when VLAN authorization is missing. This choice can be useful for that problem, but it does not establish the Mac authentication bypass for headless devices control being assessed here.

C:

Authentication failure and guest access addresses another technical failure: giving failed authentication clients ordinary production VLAN access defeats the NAC intent. This case instead tests Mac authentication bypass for headless devices; the choice measures or changes another part of the system.

Question 434

After diagnosing the FortiSwitch 7.6 issue, the engineer records: A security camera cannot perform 802.1X and is rejected on an otherwise secured switch port. Which acceptance evidence MOST DIRECTLY demonstrates the specific correction succeeded?

  1. The configured threshold is enforced and violation logs identify a port that exceeds expected MAC learning.
  2. An authenticated user receives the expected VLAN and subnet while a different identity is placed in a different approved VLAN.
  3. A registered non-802.1X device is authorized under MAB while unknown MAC identities receive restricted or no access.
  4. Failed and guest test devices enter only their configured restricted VLAN or remain denied as the policy requires.

Explanation

Correct Answer

C:

The relevant acceptance proof for this incident (A security camera cannot perform 802.1X and is rejected on an otherwise secured switch port) is: A registered non-802.1X device is authorized under MAB while unknown MAC identities receive restricted or no access. That observation tests the same failure path that prompted the change, not merely whether a physical link is up. It also helps rule out the known alternative risk: Turning off authentication globally to accommodate one printer exposes the entire access segment. Retain the documented evidence after applying the associated correction: Use MAC authentication bypass with managed RADIUS identity records for devices unable to speak 802.1X.

Incorrect Answers

A:

Learned mac limit on access port would demonstrate or implement: The configured threshold is enforced and violation logs identify a port that exceeds expected MAC learning. The case states: A security camera cannot perform 802.1X and is rejected on an otherwise secured switch port. The most direct evidence is: A registered non-802.1X device is authorized under MAB while unknown MAC identities receive restricted or no access.

B:

Radius dynamic VLAN assignment would demonstrate or implement: An authenticated user receives the expected VLAN and subnet while a different identity is placed in a different approved VLAN. This choice can be useful for that problem, but it does not establish the Mac authentication bypass for headless devices control being assessed here.

D:

Authentication failure and guest access would demonstrate or implement: Failed and guest test devices enter only their configured restricted VLAN or remain denied as the policy requires. The required evidence concerns Mac authentication bypass for headless devices; a passing result for this alternative could leave that requirement unresolved.

Question 435

At a FortiSwitchOS/FortiOS 7.6 network site, an engineer observes: An industrial sensor has no certificate support but its MAC identity is known to RADIUS. Which change MOST DIRECTLY addresses this problem without weakening the intended network design?

  1. Use supported RADIUS authorization attributes to place authenticated endpoints into the correct dynamic VLAN.
  2. Use MAC authentication bypass with managed RADIUS identity records for devices unable to speak 802.1X.
  3. Configure a restricted guest or authentication-failure VLAN according to the desired denial and remediation policy.
  4. Enforce 802.1X on suitable access ports with a reachable RADIUS service and configured authorized user groups.

Explanation

Correct Answer

B:

For the observed condition (An industrial sensor has no certificate support but its MAC identity is known to RADIUS), the appropriate response is to use MAC authentication bypass with managed RADIUS identity records for devices unable to speak 802.1X. The underlying risk is that turning off authentication globally to accommodate one printer exposes the entire access segment. This action is targeted to mac authentication bypass for headless devices rather than to a different switching feature. Confirm it by checking that a registered non-802.1X device is authorized under MAB while unknown MAC identities receive restricted or no access.

Incorrect Answers

A:

Radius dynamic VLAN assignment addresses another technical failure: authenticating a device does not guarantee it lands in the intended security segment when VLAN authorization is missing. The case states: An industrial sensor has no certificate support but its MAC identity is known to RADIUS. The most direct corrective action is: use MAC authentication bypass with managed RADIUS identity records for devices unable to speak 802.1X.

C:

Authentication failure and guest access addresses another technical failure: giving failed authentication clients ordinary production VLAN access defeats the NAC intent. This case instead tests Mac authentication bypass for headless devices; the choice measures or changes another part of the system.

D:

802.1x access authentication addresses another technical failure: enabling 802.1X without a reachable authentication service can deny all intended clients. The required corrective action concerns Mac authentication bypass for headless devices; a passing result for this alternative could leave that requirement unresolved.

Question 436

After diagnosing the FortiSwitch 7.6 issue, the engineer records: An industrial sensor has no certificate support but its MAC identity is known to RADIUS. Which acceptance evidence MOST DIRECTLY demonstrates the specific correction succeeded?

  1. An authenticated user receives the expected VLAN and subnet while a different identity is placed in a different approved VLAN.
  2. Failed and guest test devices enter only their configured restricted VLAN or remain denied as the policy requires.
  3. An authorized supplicant completes EAP and receives the specified access policy while unauthorized clients are denied.
  4. A registered non-802.1X device is authorized under MAB while unknown MAC identities receive restricted or no access.

Explanation

Correct Answer

D:

The relevant acceptance proof for this incident (An industrial sensor has no certificate support but its MAC identity is known to RADIUS) is: A registered non-802.1X device is authorized under MAB while unknown MAC identities receive restricted or no access. That observation tests the same failure path that prompted the change, not merely whether a physical link is up. It also helps rule out the known alternative risk: Turning off authentication globally to accommodate one printer exposes the entire access segment. Retain the documented evidence after applying the associated correction: Use MAC authentication bypass with managed RADIUS identity records for devices unable to speak 802.1X.

Incorrect Answers

A:

Radius dynamic VLAN assignment would demonstrate or implement: An authenticated user receives the expected VLAN and subnet while a different identity is placed in a different approved VLAN. The case states: An industrial sensor has no certificate support but its MAC identity is known to RADIUS. The most direct evidence is: A registered non-802.1X device is authorized under MAB while unknown MAC identities receive restricted or no access.

B:

Authentication failure and guest access would demonstrate or implement: Failed and guest test devices enter only their configured restricted VLAN or remain denied as the policy requires. This choice can be useful for that problem, but it does not establish the Mac authentication bypass for headless devices control being assessed here.

C:

802.1x access authentication would demonstrate or implement: An authorized supplicant completes EAP and receives the specified access policy while unauthorized clients are denied. This case instead tests Mac authentication bypass for headless devices; the choice measures or changes another part of the system.

Question 437

At a FortiSwitchOS/FortiOS 7.6 network site, an engineer observes: A label printer must join a protected VLAN without weakening adjacent employee ports. Which change MOST DIRECTLY addresses this problem without weakening the intended network design?

  1. Use MAC authentication bypass with managed RADIUS identity records for devices unable to speak 802.1X.
  2. Configure a restricted guest or authentication-failure VLAN according to the desired denial and remediation policy.
  3. Enforce 802.1X on suitable access ports with a reachable RADIUS service and configured authorized user groups.
  4. Configure supported per-port MAC learning limits or violation behavior to constrain unexpected endpoint fanout.

Explanation

Correct Answer

A:

For the observed condition (A label printer must join a protected VLAN without weakening adjacent employee ports), the appropriate response is to use MAC authentication bypass with managed RADIUS identity records for devices unable to speak 802.1X. The underlying risk is that turning off authentication globally to accommodate one printer exposes the entire access segment. This action is targeted to mac authentication bypass for headless devices rather than to a different switching feature. Confirm it by checking that a registered non-802.1X device is authorized under MAB while unknown MAC identities receive restricted or no access.

Incorrect Answers

B:

Authentication failure and guest access addresses another technical failure: giving failed authentication clients ordinary production VLAN access defeats the NAC intent. This choice can be useful for that problem, but it does not establish the Mac authentication bypass for headless devices control being assessed here.

C:

802.1x access authentication addresses another technical failure: enabling 802.1X without a reachable authentication service can deny all intended clients. This case instead tests Mac authentication bypass for headless devices; the choice measures or changes another part of the system.

D:

Learned mac limit on access port addresses another technical failure: an unrestricted access port can become an unmanaged mini-switch attachment point without detection. The required corrective action concerns Mac authentication bypass for headless devices; a passing result for this alternative could leave that requirement unresolved.

Question 438

After diagnosing the FortiSwitch 7.6 issue, the engineer records: A label printer must join a protected VLAN without weakening adjacent employee ports. Which acceptance evidence MOST DIRECTLY demonstrates the specific correction succeeded?

  1. Failed and guest test devices enter only their configured restricted VLAN or remain denied as the policy requires.
  2. An authorized supplicant completes EAP and receives the specified access policy while unauthorized clients are denied.
  3. A registered non-802.1X device is authorized under MAB while unknown MAC identities receive restricted or no access.
  4. The configured threshold is enforced and violation logs identify a port that exceeds expected MAC learning.

Explanation

Correct Answer

C:

The relevant acceptance proof for this incident (A label printer must join a protected VLAN without weakening adjacent employee ports) is: A registered non-802.1X device is authorized under MAB while unknown MAC identities receive restricted or no access. That observation tests the same failure path that prompted the change, not merely whether a physical link is up. It also helps rule out the known alternative risk: Turning off authentication globally to accommodate one printer exposes the entire access segment. Retain the documented evidence after applying the associated correction: Use MAC authentication bypass with managed RADIUS identity records for devices unable to speak 802.1X.

Incorrect Answers

A:

Authentication failure and guest access would demonstrate or implement: Failed and guest test devices enter only their configured restricted VLAN or remain denied as the policy requires. The case states: A label printer must join a protected VLAN without weakening adjacent employee ports. The most direct evidence is: A registered non-802.1X device is authorized under MAB while unknown MAC identities receive restricted or no access.

B:

802.1x access authentication would demonstrate or implement: An authorized supplicant completes EAP and receives the specified access policy while unauthorized clients are denied. This choice can be useful for that problem, but it does not establish the Mac authentication bypass for headless devices control being assessed here.

D:

Learned mac limit on access port would demonstrate or implement: The configured threshold is enforced and violation logs identify a port that exceeds expected MAC learning. The required evidence concerns Mac authentication bypass for headless devices; a passing result for this alternative could leave that requirement unresolved.

Question 439

At a FortiSwitchOS/FortiOS 7.6 network site, an engineer observes: A legacy badge reader fails 802.1X and requires a tightly managed alternative authorization method. Which change MOST DIRECTLY addresses this problem without weakening the intended network design?

  1. Enforce 802.1X on suitable access ports with a reachable RADIUS service and configured authorized user groups.
  2. Use MAC authentication bypass with managed RADIUS identity records for devices unable to speak 802.1X.
  3. Configure supported per-port MAC learning limits or violation behavior to constrain unexpected endpoint fanout.
  4. Use supported RADIUS authorization attributes to place authenticated endpoints into the correct dynamic VLAN.

Explanation

Correct Answer

B:

For the observed condition (A legacy badge reader fails 802.1X and requires a tightly managed alternative authorization method), the appropriate response is to use MAC authentication bypass with managed RADIUS identity records for devices unable to speak 802.1X. The underlying risk is that turning off authentication globally to accommodate one printer exposes the entire access segment. This action is targeted to mac authentication bypass for headless devices rather than to a different switching feature. Confirm it by checking that a registered non-802.1X device is authorized under MAB while unknown MAC identities receive restricted or no access.

Incorrect Answers

A:

802.1x access authentication addresses another technical failure: enabling 802.1X without a reachable authentication service can deny all intended clients. The case states: A legacy badge reader fails 802.1X and requires a tightly managed alternative authorization method. The most direct corrective action is: use MAC authentication bypass with managed RADIUS identity records for devices unable to speak 802.1X.

C:

Learned mac limit on access port addresses another technical failure: an unrestricted access port can become an unmanaged mini-switch attachment point without detection. This case instead tests Mac authentication bypass for headless devices; the choice measures or changes another part of the system.

D:

Radius dynamic VLAN assignment addresses another technical failure: authenticating a device does not guarantee it lands in the intended security segment when VLAN authorization is missing. The required corrective action concerns Mac authentication bypass for headless devices; a passing result for this alternative could leave that requirement unresolved.

Question 440

An operations team investigates this FortiSwitch 7.6 situation: A legacy badge reader fails 802.1X and requires a tightly managed alternative authorization method. Select TWO complementary measures: the corrective action AND evidence that it worked.

  1. Use MAC authentication bypass with managed RADIUS identity records for devices unable to speak 802.1X.
  2. A registered non-802.1X device is authorized under MAB while unknown MAC identities receive restricted or no access.
  3. Enforce 802.1X on suitable access ports with a reachable RADIUS service and configured authorized user groups.
  4. Configure supported per-port MAC learning limits or violation behavior to constrain unexpected endpoint fanout.
  5. An authenticated user receives the expected VLAN and subnet while a different identity is placed in a different approved VLAN.

Explanation

Correct Answer

A:

For the observed condition (A legacy badge reader fails 802.1X and requires a tightly managed alternative authorization method), the appropriate response is to use MAC authentication bypass with managed RADIUS identity records for devices unable to speak 802.1X. The underlying risk is that turning off authentication globally to accommodate one printer exposes the entire access segment. This action is targeted to mac authentication bypass for headless devices rather than to a different switching feature. Confirm it by checking that a registered non-802.1X device is authorized under MAB while unknown MAC identities receive restricted or no access.

B:

The relevant acceptance proof for this incident (A legacy badge reader fails 802.1X and requires a tightly managed alternative authorization method) is: A registered non-802.1X device is authorized under MAB while unknown MAC identities receive restricted or no access. That observation tests the same failure path that prompted the change, not merely whether a physical link is up. It also helps rule out the known alternative risk: Turning off authentication globally to accommodate one printer exposes the entire access segment. Retain the documented evidence after applying the associated correction: Use MAC authentication bypass with managed RADIUS identity records for devices unable to speak 802.1X.

Incorrect Answers

C:

802.1x access authentication addresses another technical failure: enabling 802.1X without a reachable authentication service can deny all intended clients. This case instead tests Mac authentication bypass for headless devices; the choice measures or changes another part of the system.

D:

Learned mac limit on access port addresses another technical failure: an unrestricted access port can become an unmanaged mini-switch attachment point without detection. The required paired action and test concerns Mac authentication bypass for headless devices; a passing result for this alternative could leave that requirement unresolved.

E:

Radius dynamic VLAN assignment would demonstrate or implement: An authenticated user receives the expected VLAN and subnet while a different identity is placed in a different approved VLAN. The paired-answer requirement concerns Mac authentication bypass for headless devices; this alternative does not provide the matching intervention and separate acceptance evidence.

Fortinet NSE 5 - FortiSwitch 7.6 Administrator (NSE5_FSW_AD-7.6) Practice Tests