mcAfee Secure Website
exam =5
exam =6

Exam Code: NSE5_FSW_AD-7.6

Exam Name: Fortinet NSE 5 - FortiSwitch 7.6 Administrator

Certification Provider: Fortinet

Corresponding Certification: NSE5

Fortinet NSE5_FSW_AD-7.6 Questions & Answers

Reliable & Actual Study Materials for NSE5_FSW_AD-7.6 Exam Success

64 Questions & Answers with Testing Engine

"NSE5_FSW_AD-7.6: Fortinet NSE 5 - FortiSwitch 7.6 Administrator" Testing Engine covers all the knowledge points of the real Fortinet NSE5_FSW_AD-7.6 exam.

The latest actual NSE5_FSW_AD-7.6 Questions & Answers from Pass4sure. Everything you need to prepare and get best score at NSE5_FSW_AD-7.6 exam easily and quickly.

exam =7
Guarantee

Satisfaction Guaranteed

Pass4sure has a remarkable Fortinet Candidate Success record. We're confident of our products and provide no hassle product exchange. That's how confident we are!

99.3% Pass Rate
Was: $137.49
Now: $124.99

Fortinet NSE5_FSW_AD-7.6 Practice Test 41

Question 400

An operations team investigates this FortiSwitch 7.6 situation: A provider FortiSwitch handoff strips the customer VLAN header instead of preserving a two-tag service frame. Select TWO complementary measures: the corrective action AND evidence that it worked.

  1. Apply tenant port changes through the authoritative controlling FortiGate context and audit the resulting mappings.
  2. Use supported 802.1ad QinQ service and customer VLAN tagging only where the target FortiOS and model capabilities allow it.
  3. Captures confirm the correct outer service VLAN and inner customer VLAN across the provider handoff.
  4. Allocate FortiSwitch port resources to the appropriate FortiGate VDOM while preserving the intended administrative domain.
  5. Tenant test packets remain in the assigned VLAN and VDOM and reach only permitted policy destinations.

Explanation

Correct Answer

B:

For the observed condition (A provider FortiSwitch handoff strips the customer VLAN header instead of preserving a two-tag service frame), the appropriate response is to use supported 802.1ad QinQ service and customer VLAN tagging only where the target FortiOS and model capabilities allow it. The underlying risk is that single-tag access VLAN configuration cannot represent independent customer VLAN spaces that overlap between tenants. This action is targeted to qinq provider and customer vlan boundary rather than to a different switching feature. Confirm it by checking that captures confirm the correct outer service VLAN and inner customer VLAN across the provider handoff.

C:

The relevant acceptance proof for this incident (A provider FortiSwitch handoff strips the customer VLAN header instead of preserving a two-tag service frame) is: Captures confirm the correct outer service VLAN and inner customer VLAN across the provider handoff. That observation tests the same failure path that prompted the change, not merely whether a physical link is up. It also helps rule out the known alternative risk: Single-tag access VLAN configuration cannot represent independent customer VLAN spaces that overlap between tenants. Retain the documented evidence after applying the associated correction: Use supported 802.1ad QinQ service and customer VLAN tagging only where the target FortiOS and model capabilities allow it.

Incorrect Answers

A:

Tenant change control and central authority addresses another technical failure: editing the wrong VDOM or making unsupported local switch changes can leave tenant segmentation inconsistent or unenforced. The case states: A provider FortiSwitch handoff strips the customer VLAN header instead of preserving a two-tag service frame. The most direct paired action and test is: use supported 802.1ad QinQ service and customer VLAN tagging only where the target FortiOS and model capabilities allow it.

D:

Vdom ownership of managed switch ports addresses another technical failure: placing a VLAN in another VDOM does not automatically transfer physical managed-switch ownership or GUI visibility. The required paired action and test concerns Qinq provider and customer VLAN boundary; a passing result for this alternative could leave that requirement unresolved.

E:

Tenant VLAN creation and mapping would demonstrate or implement: Tenant test packets remain in the assigned VLAN and VDOM and reach only permitted policy destinations. The paired-answer requirement concerns Qinq provider and customer VLAN boundary; this alternative does not provide the matching intervention and separate acceptance evidence.

Question 401

At a FortiSwitchOS/FortiOS 7.6 network site, an engineer observes: A contractor receives a dedicated wall jack that should never see corporate VLAN tags. Which change MOST DIRECTLY addresses this problem without weakening the intended network design?

  1. Allocate FortiSwitch port resources to the appropriate FortiGate VDOM while preserving the intended administrative domain.
  2. Assign dedicated FortiSwitch access ports to tenant VDOM resources with the minimum required VLAN membership.
  3. Create tenant VLAN interfaces in the intended VDOM and verify switch port membership through the controlling domain.
  4. Configure supported sharing of switch ports across VDOM VLANs only with explicit tagged membership and isolation controls.

Explanation

Correct Answer

B:

For the observed condition (A contractor receives a dedicated wall jack that should never see corporate VLAN tags), the appropriate response is to assign dedicated FortiSwitch access ports to tenant VDOM resources with the minimum required VLAN membership. The underlying risk is that leaving a tenant-facing access port open to all VLANs undermines isolation even if the FortiGate has separate VDOM policies. This action is targeted to dedicated tenant ports and least privilege rather than to a different switching feature. Confirm it by checking that port inventory and unauthorized-tenant probes demonstrate only approved tenant VLANs can enter or leave.

Incorrect Answers

A:

Vdom ownership of managed switch ports addresses another technical failure: placing a VLAN in another VDOM does not automatically transfer physical managed-switch ownership or GUI visibility. The case states: A contractor receives a dedicated wall jack that should never see corporate VLAN tags. The most direct corrective action is: assign dedicated FortiSwitch access ports to tenant VDOM resources with the minimum required VLAN membership.

C:

Tenant VLAN creation and mapping addresses another technical failure: reusing a VLAN name without validating VDOM and underlying VLAN ID can leak or misroute tenant traffic. This case instead tests Dedicated tenant ports and least privilege; the choice measures or changes another part of the system.

D:

Shared physical port multitenancy addresses another technical failure: a shared trunk without clear VLAN-to-VDOM ownership can expose one tenant to another's broadcast domain. The required corrective action concerns Dedicated tenant ports and least privilege; a passing result for this alternative could leave that requirement unresolved.

Question 402

After diagnosing the FortiSwitch 7.6 issue, the engineer records: A contractor receives a dedicated wall jack that should never see corporate VLAN tags. Which acceptance evidence MOST DIRECTLY demonstrates the specific correction succeeded?

  1. The controller VDOM inventory and tenant port assignment match the approved access segregation plan.
  2. Tenant test packets remain in the assigned VLAN and VDOM and reach only permitted policy destinations.
  3. Port inventory and unauthorized-tenant probes demonstrate only approved tenant VLANs can enter or leave.
  4. Tagged tenant test flows traverse only their allowed VLANs and remain isolated at the FortiGate VDOM boundary.

Explanation

Correct Answer

C:

The relevant acceptance proof for this incident (A contractor receives a dedicated wall jack that should never see corporate VLAN tags) is: Port inventory and unauthorized-tenant probes demonstrate only approved tenant VLANs can enter or leave. That observation tests the same failure path that prompted the change, not merely whether a physical link is up. It also helps rule out the known alternative risk: Leaving a tenant-facing access port open to all VLANs undermines isolation even if the FortiGate has separate VDOM policies. Retain the documented evidence after applying the associated correction: Assign dedicated FortiSwitch access ports to tenant VDOM resources with the minimum required VLAN membership.

Incorrect Answers

A:

Vdom ownership of managed switch ports would demonstrate or implement: The controller VDOM inventory and tenant port assignment match the approved access segregation plan. The case states: A contractor receives a dedicated wall jack that should never see corporate VLAN tags. The most direct evidence is: Port inventory and unauthorized-tenant probes demonstrate only approved tenant VLANs can enter or leave.

B:

Tenant VLAN creation and mapping would demonstrate or implement: Tenant test packets remain in the assigned VLAN and VDOM and reach only permitted policy destinations. This choice can be useful for that problem, but it does not establish the Dedicated tenant ports and least privilege control being assessed here.

D:

Shared physical port multitenancy would demonstrate or implement: Tagged tenant test flows traverse only their allowed VLANs and remain isolated at the FortiGate VDOM boundary. The required evidence concerns Dedicated tenant ports and least privilege; a passing result for this alternative could leave that requirement unresolved.

Question 403

At a FortiSwitchOS/FortiOS 7.6 network site, an engineer observes: An MSP assigns a physical switch port per customer but the default port template allows all VLANs. Which change MOST DIRECTLY addresses this problem without weakening the intended network design?

  1. Create tenant VLAN interfaces in the intended VDOM and verify switch port membership through the controlling domain.
  2. Configure supported sharing of switch ports across VDOM VLANs only with explicit tagged membership and isolation controls.
  3. Assign dedicated FortiSwitch access ports to tenant VDOM resources with the minimum required VLAN membership.
  4. Use supported 802.1ad QinQ service and customer VLAN tagging only where the target FortiOS and model capabilities allow it.

Explanation

Correct Answer

C:

For the observed condition (An MSP assigns a physical switch port per customer but the default port template allows all VLANs), the appropriate response is to assign dedicated FortiSwitch access ports to tenant VDOM resources with the minimum required VLAN membership. The underlying risk is that leaving a tenant-facing access port open to all VLANs undermines isolation even if the FortiGate has separate VDOM policies. This action is targeted to dedicated tenant ports and least privilege rather than to a different switching feature. Confirm it by checking that port inventory and unauthorized-tenant probes demonstrate only approved tenant VLANs can enter or leave.

Incorrect Answers

A:

Tenant VLAN creation and mapping addresses another technical failure: reusing a VLAN name without validating VDOM and underlying VLAN ID can leak or misroute tenant traffic. The case states: An MSP assigns a physical switch port per customer but the default port template allows all VLANs. The most direct corrective action is: assign dedicated FortiSwitch access ports to tenant VDOM resources with the minimum required VLAN membership.

B:

Shared physical port multitenancy addresses another technical failure: a shared trunk without clear VLAN-to-VDOM ownership can expose one tenant to another's broadcast domain. This choice can be useful for that problem, but it does not establish the Dedicated tenant ports and least privilege control being assessed here.

D:

Qinq provider and customer VLAN boundary addresses another technical failure: single-tag access VLAN configuration cannot represent independent customer VLAN spaces that overlap between tenants. The required corrective action concerns Dedicated tenant ports and least privilege; a passing result for this alternative could leave that requirement unresolved.

Question 404

After diagnosing the FortiSwitch 7.6 issue, the engineer records: An MSP assigns a physical switch port per customer but the default port template allows all VLANs. Which acceptance evidence MOST DIRECTLY demonstrates the specific correction succeeded?

  1. Tenant test packets remain in the assigned VLAN and VDOM and reach only permitted policy destinations.
  2. Tagged tenant test flows traverse only their allowed VLANs and remain isolated at the FortiGate VDOM boundary.
  3. Captures confirm the correct outer service VLAN and inner customer VLAN across the provider handoff.
  4. Port inventory and unauthorized-tenant probes demonstrate only approved tenant VLANs can enter or leave.

Explanation

Correct Answer

D:

The relevant acceptance proof for this incident (An MSP assigns a physical switch port per customer but the default port template allows all VLANs) is: Port inventory and unauthorized-tenant probes demonstrate only approved tenant VLANs can enter or leave. That observation tests the same failure path that prompted the change, not merely whether a physical link is up. It also helps rule out the known alternative risk: Leaving a tenant-facing access port open to all VLANs undermines isolation even if the FortiGate has separate VDOM policies. Retain the documented evidence after applying the associated correction: Assign dedicated FortiSwitch access ports to tenant VDOM resources with the minimum required VLAN membership.

Incorrect Answers

A:

Tenant VLAN creation and mapping would demonstrate or implement: Tenant test packets remain in the assigned VLAN and VDOM and reach only permitted policy destinations. The case states: An MSP assigns a physical switch port per customer but the default port template allows all VLANs. The most direct evidence is: Port inventory and unauthorized-tenant probes demonstrate only approved tenant VLANs can enter or leave.

B:

Shared physical port multitenancy would demonstrate or implement: Tagged tenant test flows traverse only their allowed VLANs and remain isolated at the FortiGate VDOM boundary. This choice can be useful for that problem, but it does not establish the Dedicated tenant ports and least privilege control being assessed here.

C:

Qinq provider and customer VLAN boundary would demonstrate or implement: Captures confirm the correct outer service VLAN and inner customer VLAN across the provider handoff. This case instead tests Dedicated tenant ports and least privilege; the choice measures or changes another part of the system.

Question 405

At a FortiSwitchOS/FortiOS 7.6 network site, an engineer observes: A hotel guest tenant is connected to a dedicated access port configured with an employee native VLAN. Which change MOST DIRECTLY addresses this problem without weakening the intended network design?

  1. Assign dedicated FortiSwitch access ports to tenant VDOM resources with the minimum required VLAN membership.
  2. Configure supported sharing of switch ports across VDOM VLANs only with explicit tagged membership and isolation controls.
  3. Use supported 802.1ad QinQ service and customer VLAN tagging only where the target FortiOS and model capabilities allow it.
  4. Apply tenant port changes through the authoritative controlling FortiGate context and audit the resulting mappings.

Explanation

Correct Answer

A:

For the observed condition (A hotel guest tenant is connected to a dedicated access port configured with an employee native VLAN), the appropriate response is to assign dedicated FortiSwitch access ports to tenant VDOM resources with the minimum required VLAN membership. The underlying risk is that leaving a tenant-facing access port open to all VLANs undermines isolation even if the FortiGate has separate VDOM policies. This action is targeted to dedicated tenant ports and least privilege rather than to a different switching feature. Confirm it by checking that port inventory and unauthorized-tenant probes demonstrate only approved tenant VLANs can enter or leave.

Incorrect Answers

B:

Shared physical port multitenancy addresses another technical failure: a shared trunk without clear VLAN-to-VDOM ownership can expose one tenant to another's broadcast domain. This choice can be useful for that problem, but it does not establish the Dedicated tenant ports and least privilege control being assessed here.

C:

Qinq provider and customer VLAN boundary addresses another technical failure: single-tag access VLAN configuration cannot represent independent customer VLAN spaces that overlap between tenants. This case instead tests Dedicated tenant ports and least privilege; the choice measures or changes another part of the system.

D:

Tenant change control and central authority addresses another technical failure: editing the wrong VDOM or making unsupported local switch changes can leave tenant segmentation inconsistent or unenforced. The required corrective action concerns Dedicated tenant ports and least privilege; a passing result for this alternative could leave that requirement unresolved.

Question 406

After diagnosing the FortiSwitch 7.6 issue, the engineer records: A hotel guest tenant is connected to a dedicated access port configured with an employee native VLAN. Which acceptance evidence MOST DIRECTLY demonstrates the specific correction succeeded?

  1. Tagged tenant test flows traverse only their allowed VLANs and remain isolated at the FortiGate VDOM boundary.
  2. Port inventory and unauthorized-tenant probes demonstrate only approved tenant VLANs can enter or leave.
  3. Captures confirm the correct outer service VLAN and inner customer VLAN across the provider handoff.
  4. Change logs and configuration diffs identify the controlling domain and the effective port-to-tenant VLAN mapping.

Explanation

Correct Answer

B:

The relevant acceptance proof for this incident (A hotel guest tenant is connected to a dedicated access port configured with an employee native VLAN) is: Port inventory and unauthorized-tenant probes demonstrate only approved tenant VLANs can enter or leave. That observation tests the same failure path that prompted the change, not merely whether a physical link is up. It also helps rule out the known alternative risk: Leaving a tenant-facing access port open to all VLANs undermines isolation even if the FortiGate has separate VDOM policies. Retain the documented evidence after applying the associated correction: Assign dedicated FortiSwitch access ports to tenant VDOM resources with the minimum required VLAN membership.

Incorrect Answers

A:

Shared physical port multitenancy would demonstrate or implement: Tagged tenant test flows traverse only their allowed VLANs and remain isolated at the FortiGate VDOM boundary. The case states: A hotel guest tenant is connected to a dedicated access port configured with an employee native VLAN. The most direct evidence is: Port inventory and unauthorized-tenant probes demonstrate only approved tenant VLANs can enter or leave.

C:

Qinq provider and customer VLAN boundary would demonstrate or implement: Captures confirm the correct outer service VLAN and inner customer VLAN across the provider handoff. This case instead tests Dedicated tenant ports and least privilege; the choice measures or changes another part of the system.

D:

Tenant change control and central authority would demonstrate or implement: Change logs and configuration diffs identify the controlling domain and the effective port-to-tenant VLAN mapping. The required evidence concerns Dedicated tenant ports and least privilege; a passing result for this alternative could leave that requirement unresolved.

Question 407

At a FortiSwitchOS/FortiOS 7.6 network site, an engineer observes: A healthcare tenant needs an isolated access port with no cross-tenant broadcast reachability. Which change MOST DIRECTLY addresses this problem without weakening the intended network design?

  1. Use supported 802.1ad QinQ service and customer VLAN tagging only where the target FortiOS and model capabilities allow it.
  2. Apply tenant port changes through the authoritative controlling FortiGate context and audit the resulting mappings.
  3. Allocate FortiSwitch port resources to the appropriate FortiGate VDOM while preserving the intended administrative domain.
  4. Assign dedicated FortiSwitch access ports to tenant VDOM resources with the minimum required VLAN membership.

Explanation

Correct Answer

D:

For the observed condition (A healthcare tenant needs an isolated access port with no cross-tenant broadcast reachability), the appropriate response is to assign dedicated FortiSwitch access ports to tenant VDOM resources with the minimum required VLAN membership. The underlying risk is that leaving a tenant-facing access port open to all VLANs undermines isolation even if the FortiGate has separate VDOM policies. This action is targeted to dedicated tenant ports and least privilege rather than to a different switching feature. Confirm it by checking that port inventory and unauthorized-tenant probes demonstrate only approved tenant VLANs can enter or leave.

Incorrect Answers

A:

Qinq provider and customer VLAN boundary addresses another technical failure: single-tag access VLAN configuration cannot represent independent customer VLAN spaces that overlap between tenants. The case states: A healthcare tenant needs an isolated access port with no cross-tenant broadcast reachability. The most direct corrective action is: assign dedicated FortiSwitch access ports to tenant VDOM resources with the minimum required VLAN membership.

B:

Tenant change control and central authority addresses another technical failure: editing the wrong VDOM or making unsupported local switch changes can leave tenant segmentation inconsistent or unenforced. This choice can be useful for that problem, but it does not establish the Dedicated tenant ports and least privilege control being assessed here.

C:

Vdom ownership of managed switch ports addresses another technical failure: placing a VLAN in another VDOM does not automatically transfer physical managed-switch ownership or GUI visibility. This case instead tests Dedicated tenant ports and least privilege; the choice measures or changes another part of the system.

Question 408

After diagnosing the FortiSwitch 7.6 issue, the engineer records: A healthcare tenant needs an isolated access port with no cross-tenant broadcast reachability. Which acceptance evidence MOST DIRECTLY demonstrates the specific correction succeeded?

  1. Captures confirm the correct outer service VLAN and inner customer VLAN across the provider handoff.
  2. Change logs and configuration diffs identify the controlling domain and the effective port-to-tenant VLAN mapping.
  3. Port inventory and unauthorized-tenant probes demonstrate only approved tenant VLANs can enter or leave.
  4. The controller VDOM inventory and tenant port assignment match the approved access segregation plan.

Explanation

Correct Answer

C:

The relevant acceptance proof for this incident (A healthcare tenant needs an isolated access port with no cross-tenant broadcast reachability) is: Port inventory and unauthorized-tenant probes demonstrate only approved tenant VLANs can enter or leave. That observation tests the same failure path that prompted the change, not merely whether a physical link is up. It also helps rule out the known alternative risk: Leaving a tenant-facing access port open to all VLANs undermines isolation even if the FortiGate has separate VDOM policies. Retain the documented evidence after applying the associated correction: Assign dedicated FortiSwitch access ports to tenant VDOM resources with the minimum required VLAN membership.

Incorrect Answers

A:

Qinq provider and customer VLAN boundary would demonstrate or implement: Captures confirm the correct outer service VLAN and inner customer VLAN across the provider handoff. The case states: A healthcare tenant needs an isolated access port with no cross-tenant broadcast reachability. The most direct evidence is: Port inventory and unauthorized-tenant probes demonstrate only approved tenant VLANs can enter or leave.

B:

Tenant change control and central authority would demonstrate or implement: Change logs and configuration diffs identify the controlling domain and the effective port-to-tenant VLAN mapping. This choice can be useful for that problem, but it does not establish the Dedicated tenant ports and least privilege control being assessed here.

D:

Vdom ownership of managed switch ports would demonstrate or implement: The controller VDOM inventory and tenant port assignment match the approved access segregation plan. The required evidence concerns Dedicated tenant ports and least privilege; a passing result for this alternative could leave that requirement unresolved.

Question 409

At a FortiSwitchOS/FortiOS 7.6 network site, an engineer observes: A newly provisioned tenant switch port inherits another tenant's allowed VLAN list. Which change MOST DIRECTLY addresses this problem without weakening the intended network design?

  1. Apply tenant port changes through the authoritative controlling FortiGate context and audit the resulting mappings.
  2. Assign dedicated FortiSwitch access ports to tenant VDOM resources with the minimum required VLAN membership.
  3. Allocate FortiSwitch port resources to the appropriate FortiGate VDOM while preserving the intended administrative domain.
  4. Create tenant VLAN interfaces in the intended VDOM and verify switch port membership through the controlling domain.

Explanation

Correct Answer

B:

For the observed condition (A newly provisioned tenant switch port inherits another tenant's allowed VLAN list), the appropriate response is to assign dedicated FortiSwitch access ports to tenant VDOM resources with the minimum required VLAN membership. The underlying risk is that leaving a tenant-facing access port open to all VLANs undermines isolation even if the FortiGate has separate VDOM policies. This action is targeted to dedicated tenant ports and least privilege rather than to a different switching feature. Confirm it by checking that port inventory and unauthorized-tenant probes demonstrate only approved tenant VLANs can enter or leave.

Incorrect Answers

A:

Tenant change control and central authority addresses another technical failure: editing the wrong VDOM or making unsupported local switch changes can leave tenant segmentation inconsistent or unenforced. The case states: A newly provisioned tenant switch port inherits another tenant's allowed VLAN list. The most direct corrective action is: assign dedicated FortiSwitch access ports to tenant VDOM resources with the minimum required VLAN membership.

C:

Vdom ownership of managed switch ports addresses another technical failure: placing a VLAN in another VDOM does not automatically transfer physical managed-switch ownership or GUI visibility. This case instead tests Dedicated tenant ports and least privilege; the choice measures or changes another part of the system.

D:

Tenant VLAN creation and mapping addresses another technical failure: reusing a VLAN name without validating VDOM and underlying VLAN ID can leak or misroute tenant traffic. The required corrective action concerns Dedicated tenant ports and least privilege; a passing result for this alternative could leave that requirement unresolved.

Question 410

An operations team investigates this FortiSwitch 7.6 situation: A newly provisioned tenant switch port inherits another tenant's allowed VLAN list. Select TWO complementary measures: the corrective action AND evidence that it worked.

  1. Assign dedicated FortiSwitch access ports to tenant VDOM resources with the minimum required VLAN membership.
  2. Port inventory and unauthorized-tenant probes demonstrate only approved tenant VLANs can enter or leave.
  3. Apply tenant port changes through the authoritative controlling FortiGate context and audit the resulting mappings.
  4. Allocate FortiSwitch port resources to the appropriate FortiGate VDOM while preserving the intended administrative domain.
  5. Tenant test packets remain in the assigned VLAN and VDOM and reach only permitted policy destinations.

Explanation

Correct Answer

A:

For the observed condition (A newly provisioned tenant switch port inherits another tenant's allowed VLAN list), the appropriate response is to assign dedicated FortiSwitch access ports to tenant VDOM resources with the minimum required VLAN membership. The underlying risk is that leaving a tenant-facing access port open to all VLANs undermines isolation even if the FortiGate has separate VDOM policies. This action is targeted to dedicated tenant ports and least privilege rather than to a different switching feature. Confirm it by checking that port inventory and unauthorized-tenant probes demonstrate only approved tenant VLANs can enter or leave.

B:

The relevant acceptance proof for this incident (A newly provisioned tenant switch port inherits another tenant's allowed VLAN list) is: Port inventory and unauthorized-tenant probes demonstrate only approved tenant VLANs can enter or leave. That observation tests the same failure path that prompted the change, not merely whether a physical link is up. It also helps rule out the known alternative risk: Leaving a tenant-facing access port open to all VLANs undermines isolation even if the FortiGate has separate VDOM policies. Retain the documented evidence after applying the associated correction: Assign dedicated FortiSwitch access ports to tenant VDOM resources with the minimum required VLAN membership.

Incorrect Answers

C:

Tenant change control and central authority addresses another technical failure: editing the wrong VDOM or making unsupported local switch changes can leave tenant segmentation inconsistent or unenforced. This case instead tests Dedicated tenant ports and least privilege; the choice measures or changes another part of the system.

D:

Vdom ownership of managed switch ports addresses another technical failure: placing a VLAN in another VDOM does not automatically transfer physical managed-switch ownership or GUI visibility. The required paired action and test concerns Dedicated tenant ports and least privilege; a passing result for this alternative could leave that requirement unresolved.

E:

Tenant VLAN creation and mapping would demonstrate or implement: Tenant test packets remain in the assigned VLAN and VDOM and reach only permitted policy destinations. The paired-answer requirement concerns Dedicated tenant ports and least privilege; this alternative does not provide the matching intervention and separate acceptance evidence.

Fortinet NSE 5 - FortiSwitch 7.6 Administrator (NSE5_FSW_AD-7.6) Practice Tests