mcAfee Secure Website
exam =5
exam =6

Exam Code: NSE5_FSW_AD-7.6

Exam Name: Fortinet NSE 5 - FortiSwitch 7.6 Administrator

Certification Provider: Fortinet

Corresponding Certification: NSE5

Fortinet NSE5_FSW_AD-7.6 Questions & Answers

Reliable & Actual Study Materials for NSE5_FSW_AD-7.6 Exam Success

64 Questions & Answers with Testing Engine

"NSE5_FSW_AD-7.6: Fortinet NSE 5 - FortiSwitch 7.6 Administrator" Testing Engine covers all the knowledge points of the real Fortinet NSE5_FSW_AD-7.6 exam.

The latest actual NSE5_FSW_AD-7.6 Questions & Answers from Pass4sure. Everything you need to prepare and get best score at NSE5_FSW_AD-7.6 exam easily and quickly.

exam =7
Guarantee

Satisfaction Guaranteed

Pass4sure has a remarkable Fortinet Candidate Success record. We're confident of our products and provide no hassle product exchange. That's how confident we are!

99.3% Pass Rate
Was: $137.49
Now: $124.99

Fortinet NSE5_FSW_AD-7.6 Practice Test 1

Question 1

At a FortiSwitchOS/FortiOS 7.6 network site, an engineer observes: A lobby kiosk sends untagged frames but obtains an address from the guest subnet rather than the employee subnet. Which change MOST DIRECTLY addresses this problem without weakening the intended network design?

  1. Add the required tagged VLAN to the allowed list on each relevant trunk while retaining segmentation rules.
  2. Match the endpoint's tagging expectation by setting native and untagged VLAN behavior on the egress port.
  3. Create or verify the routed VLAN interfaces and FortiGate security policy needed for authorized communication between VLANs.
  4. Correct the native VLAN on the user-facing port so untagged frames enter the intended endpoint VLAN.

Explanation

Correct Answer

D:

For the observed condition (A lobby kiosk sends untagged frames but obtains an address from the guest subnet rather than the employee subnet), the appropriate response is to correct the native VLAN on the user-facing port so untagged frames enter the intended endpoint VLAN. The underlying risk is that changing only an uplink allowed list cannot repair a wrong access-port PVID for untagged devices. This action is targeted to native vlan on access port rather than to a different switching feature. Confirm it by checking that an untagged test client obtains an address from the correct subnet and its ingress MAC is learned in the intended VLAN.

Incorrect Answers

A:

Tagged VLAN allowed list on trunk addresses another technical failure: creating the VLAN in the database does not itself authorize its frames across every trunk hop. The case states: A lobby kiosk sends untagged frames but obtains an address from the guest subnet rather than the employee subnet. The most direct corrective action is: correct the native VLAN on the user-facing port so untagged frames enter the intended endpoint VLAN.

B:

Tagged versus untagged egress addresses another technical failure: a port that transmits 802.1Q tags to an untagged-only endpoint can break connectivity even with correct VLAN creation. This choice can be useful for that problem, but it does not establish the Native VLAN on access port control being assessed here.

C:

Inter-VLAN routing boundary addresses another technical failure: a Layer 2 VLAN alone isolates broadcasts and never creates permission to route between subnets. This case instead tests Native VLAN on access port; the choice measures or changes another part of the system.

Question 2

After diagnosing the FortiSwitch 7.6 issue, the engineer records: A lobby kiosk sends untagged frames but obtains an address from the guest subnet rather than the employee subnet. Which acceptance evidence MOST DIRECTLY demonstrates the specific correction succeeded?

  1. An untagged test client obtains an address from the correct subnet and its ingress MAC is learned in the intended VLAN.
  2. A tagged probe traverses the intended trunk path and the VLAN appears on both ends with consistent membership.
  3. Packet capture at the endpoint shows untagged frames when required and the expected VLAN assignment upstream.
  4. A client reaches the approved destination subnet through the intended gateway while forbidden inter-VLAN flows remain blocked.

Explanation

Correct Answer

A:

The relevant acceptance proof for this incident (A lobby kiosk sends untagged frames but obtains an address from the guest subnet rather than the employee subnet) is: An untagged test client obtains an address from the correct subnet and its ingress MAC is learned in the intended VLAN. That observation tests the same failure path that prompted the change, not merely whether a physical link is up. It also helps rule out the known alternative risk: Changing only an uplink allowed list cannot repair a wrong access-port PVID for untagged devices. Retain the documented evidence after applying the associated correction: Correct the native VLAN on the user-facing port so untagged frames enter the intended endpoint VLAN.

Incorrect Answers

B:

Tagged VLAN allowed list on trunk would demonstrate or implement: A tagged probe traverses the intended trunk path and the VLAN appears on both ends with consistent membership. This choice can be useful for that problem, but it does not establish the Native VLAN on access port control being assessed here.

C:

Tagged versus untagged egress would demonstrate or implement: Packet capture at the endpoint shows untagged frames when required and the expected VLAN assignment upstream. This case instead tests Native VLAN on access port; the choice measures or changes another part of the system.

D:

Inter-VLAN routing boundary would demonstrate or implement: A client reaches the approved destination subnet through the intended gateway while forbidden inter-VLAN flows remain blocked. The required evidence concerns Native VLAN on access port; a passing result for this alternative could leave that requirement unresolved.

Question 3

At a FortiSwitchOS/FortiOS 7.6 network site, an engineer observes: A printer attached to port12 enters the camera broadcast domain despite its cable being connected correctly. Which change MOST DIRECTLY addresses this problem without weakening the intended network design?

  1. Correct the native VLAN on the user-facing port so untagged frames enter the intended endpoint VLAN.
  2. Match the endpoint's tagging expectation by setting native and untagged VLAN behavior on the egress port.
  3. Create or verify the routed VLAN interfaces and FortiGate security policy needed for authorized communication between VLANs.
  4. Add the required tagged VLAN to the allowed list on each relevant trunk while retaining segmentation rules.

Explanation

Correct Answer

A:

For the observed condition (A printer attached to port12 enters the camera broadcast domain despite its cable being connected correctly), the appropriate response is to correct the native VLAN on the user-facing port so untagged frames enter the intended endpoint VLAN. The underlying risk is that changing only an uplink allowed list cannot repair a wrong access-port PVID for untagged devices. This action is targeted to native vlan on access port rather than to a different switching feature. Confirm it by checking that an untagged test client obtains an address from the correct subnet and its ingress MAC is learned in the intended VLAN.

Incorrect Answers

B:

Tagged versus untagged egress addresses another technical failure: a port that transmits 802.1Q tags to an untagged-only endpoint can break connectivity even with correct VLAN creation. This choice can be useful for that problem, but it does not establish the Native VLAN on access port control being assessed here.

C:

Inter-VLAN routing boundary addresses another technical failure: a Layer 2 VLAN alone isolates broadcasts and never creates permission to route between subnets. This case instead tests Native VLAN on access port; the choice measures or changes another part of the system.

D:

Tagged VLAN allowed list on trunk addresses another technical failure: creating the VLAN in the database does not itself authorize its frames across every trunk hop. The required corrective action concerns Native VLAN on access port; a passing result for this alternative could leave that requirement unresolved.

Question 4

After diagnosing the FortiSwitch 7.6 issue, the engineer records: A printer attached to port12 enters the camera broadcast domain despite its cable being connected correctly. Which acceptance evidence MOST DIRECTLY demonstrates the specific correction succeeded?

  1. Packet capture at the endpoint shows untagged frames when required and the expected VLAN assignment upstream.
  2. A client reaches the approved destination subnet through the intended gateway while forbidden inter-VLAN flows remain blocked.
  3. An untagged test client obtains an address from the correct subnet and its ingress MAC is learned in the intended VLAN.
  4. A tagged probe traverses the intended trunk path and the VLAN appears on both ends with consistent membership.

Explanation

Correct Answer

C:

The relevant acceptance proof for this incident (A printer attached to port12 enters the camera broadcast domain despite its cable being connected correctly) is: An untagged test client obtains an address from the correct subnet and its ingress MAC is learned in the intended VLAN. That observation tests the same failure path that prompted the change, not merely whether a physical link is up. It also helps rule out the known alternative risk: Changing only an uplink allowed list cannot repair a wrong access-port PVID for untagged devices. Retain the documented evidence after applying the associated correction: Correct the native VLAN on the user-facing port so untagged frames enter the intended endpoint VLAN.

Incorrect Answers

A:

Tagged versus untagged egress would demonstrate or implement: Packet capture at the endpoint shows untagged frames when required and the expected VLAN assignment upstream. The case states: A printer attached to port12 enters the camera broadcast domain despite its cable being connected correctly. The most direct evidence is: An untagged test client obtains an address from the correct subnet and its ingress MAC is learned in the intended VLAN.

B:

Inter-VLAN routing boundary would demonstrate or implement: A client reaches the approved destination subnet through the intended gateway while forbidden inter-VLAN flows remain blocked. This choice can be useful for that problem, but it does not establish the Native VLAN on access port control being assessed here.

D:

Tagged VLAN allowed list on trunk would demonstrate or implement: A tagged probe traverses the intended trunk path and the VLAN appears on both ends with consistent membership. The required evidence concerns Native VLAN on access port; a passing result for this alternative could leave that requirement unresolved.

Question 5

At a FortiSwitchOS/FortiOS 7.6 network site, an engineer observes: Following a port template rollout a workstation has link but ARP reaches the wrong VLAN gateway. Which change MOST DIRECTLY addresses this problem without weakening the intended network design?

  1. Create or verify the routed VLAN interfaces and FortiGate security policy needed for authorized communication between VLANs.
  2. Add the required tagged VLAN to the allowed list on each relevant trunk while retaining segmentation rules.
  3. Correct the native VLAN on the user-facing port so untagged frames enter the intended endpoint VLAN.
  4. Match the endpoint's tagging expectation by setting native and untagged VLAN behavior on the egress port.

Explanation

Correct Answer

C:

For the observed condition (Following a port template rollout a workstation has link but ARP reaches the wrong VLAN gateway), the appropriate response is to correct the native VLAN on the user-facing port so untagged frames enter the intended endpoint VLAN. The underlying risk is that changing only an uplink allowed list cannot repair a wrong access-port PVID for untagged devices. This action is targeted to native vlan on access port rather than to a different switching feature. Confirm it by checking that an untagged test client obtains an address from the correct subnet and its ingress MAC is learned in the intended VLAN.

Incorrect Answers

A:

Inter-VLAN routing boundary addresses another technical failure: a Layer 2 VLAN alone isolates broadcasts and never creates permission to route between subnets. The case states: Following a port template rollout a workstation has link but ARP reaches the wrong VLAN gateway. The most direct corrective action is: correct the native VLAN on the user-facing port so untagged frames enter the intended endpoint VLAN.

B:

Tagged VLAN allowed list on trunk addresses another technical failure: creating the VLAN in the database does not itself authorize its frames across every trunk hop. This choice can be useful for that problem, but it does not establish the Native VLAN on access port control being assessed here.

D:

Tagged versus untagged egress addresses another technical failure: a port that transmits 802.1Q tags to an untagged-only endpoint can break connectivity even with correct VLAN creation. The required corrective action concerns Native VLAN on access port; a passing result for this alternative could leave that requirement unresolved.

Question 6

After diagnosing the FortiSwitch 7.6 issue, the engineer records: Following a port template rollout a workstation has link but ARP reaches the wrong VLAN gateway. Which acceptance evidence MOST DIRECTLY demonstrates the specific correction succeeded?

  1. An untagged test client obtains an address from the correct subnet and its ingress MAC is learned in the intended VLAN.
  2. A client reaches the approved destination subnet through the intended gateway while forbidden inter-VLAN flows remain blocked.
  3. A tagged probe traverses the intended trunk path and the VLAN appears on both ends with consistent membership.
  4. Packet capture at the endpoint shows untagged frames when required and the expected VLAN assignment upstream.

Explanation

Correct Answer

A:

The relevant acceptance proof for this incident (Following a port template rollout a workstation has link but ARP reaches the wrong VLAN gateway) is: An untagged test client obtains an address from the correct subnet and its ingress MAC is learned in the intended VLAN. That observation tests the same failure path that prompted the change, not merely whether a physical link is up. It also helps rule out the known alternative risk: Changing only an uplink allowed list cannot repair a wrong access-port PVID for untagged devices. Retain the documented evidence after applying the associated correction: Correct the native VLAN on the user-facing port so untagged frames enter the intended endpoint VLAN.

Incorrect Answers

B:

Inter-VLAN routing boundary would demonstrate or implement: A client reaches the approved destination subnet through the intended gateway while forbidden inter-VLAN flows remain blocked. This choice can be useful for that problem, but it does not establish the Native VLAN on access port control being assessed here.

C:

Tagged VLAN allowed list on trunk would demonstrate or implement: A tagged probe traverses the intended trunk path and the VLAN appears on both ends with consistent membership. This case instead tests Native VLAN on access port; the choice measures or changes another part of the system.

D:

Tagged versus untagged egress would demonstrate or implement: Packet capture at the endpoint shows untagged frames when required and the expected VLAN assignment upstream. The required evidence concerns Native VLAN on access port; a passing result for this alternative could leave that requirement unresolved.

Question 7

At a FortiSwitchOS/FortiOS 7.6 network site, an engineer observes: A reception desktop receives DHCP offers from the contractor VLAN after a switch replacement. Which change MOST DIRECTLY addresses this problem without weakening the intended network design?

  1. Correct the native VLAN on the user-facing port so untagged frames enter the intended endpoint VLAN.
  2. Add the required tagged VLAN to the allowed list on each relevant trunk while retaining segmentation rules.
  3. Match the endpoint's tagging expectation by setting native and untagged VLAN behavior on the egress port.
  4. Create or verify the routed VLAN interfaces and FortiGate security policy needed for authorized communication between VLANs.

Explanation

Correct Answer

A:

For the observed condition (A reception desktop receives DHCP offers from the contractor VLAN after a switch replacement), the appropriate response is to correct the native VLAN on the user-facing port so untagged frames enter the intended endpoint VLAN. The underlying risk is that changing only an uplink allowed list cannot repair a wrong access-port PVID for untagged devices. This action is targeted to native vlan on access port rather than to a different switching feature. Confirm it by checking that an untagged test client obtains an address from the correct subnet and its ingress MAC is learned in the intended VLAN.

Incorrect Answers

B:

Tagged VLAN allowed list on trunk addresses another technical failure: creating the VLAN in the database does not itself authorize its frames across every trunk hop. This choice can be useful for that problem, but it does not establish the Native VLAN on access port control being assessed here.

C:

Tagged versus untagged egress addresses another technical failure: a port that transmits 802.1Q tags to an untagged-only endpoint can break connectivity even with correct VLAN creation. This case instead tests Native VLAN on access port; the choice measures or changes another part of the system.

D:

Inter-VLAN routing boundary addresses another technical failure: a Layer 2 VLAN alone isolates broadcasts and never creates permission to route between subnets. The required corrective action concerns Native VLAN on access port; a passing result for this alternative could leave that requirement unresolved.

Question 8

After diagnosing the FortiSwitch 7.6 issue, the engineer records: A reception desktop receives DHCP offers from the contractor VLAN after a switch replacement. Which acceptance evidence MOST DIRECTLY demonstrates the specific correction succeeded?

  1. A tagged probe traverses the intended trunk path and the VLAN appears on both ends with consistent membership.
  2. An untagged test client obtains an address from the correct subnet and its ingress MAC is learned in the intended VLAN.
  3. Packet capture at the endpoint shows untagged frames when required and the expected VLAN assignment upstream.
  4. A client reaches the approved destination subnet through the intended gateway while forbidden inter-VLAN flows remain blocked.

Explanation

Correct Answer

B:

The relevant acceptance proof for this incident (A reception desktop receives DHCP offers from the contractor VLAN after a switch replacement) is: An untagged test client obtains an address from the correct subnet and its ingress MAC is learned in the intended VLAN. That observation tests the same failure path that prompted the change, not merely whether a physical link is up. It also helps rule out the known alternative risk: Changing only an uplink allowed list cannot repair a wrong access-port PVID for untagged devices. Retain the documented evidence after applying the associated correction: Correct the native VLAN on the user-facing port so untagged frames enter the intended endpoint VLAN.

Incorrect Answers

A:

Tagged VLAN allowed list on trunk would demonstrate or implement: A tagged probe traverses the intended trunk path and the VLAN appears on both ends with consistent membership. The case states: A reception desktop receives DHCP offers from the contractor VLAN after a switch replacement. The most direct evidence is: An untagged test client obtains an address from the correct subnet and its ingress MAC is learned in the intended VLAN.

C:

Tagged versus untagged egress would demonstrate or implement: Packet capture at the endpoint shows untagged frames when required and the expected VLAN assignment upstream. This case instead tests Native VLAN on access port; the choice measures or changes another part of the system.

D:

Inter-VLAN routing boundary would demonstrate or implement: A client reaches the approved destination subnet through the intended gateway while forbidden inter-VLAN flows remain blocked. The required evidence concerns Native VLAN on access port; a passing result for this alternative could leave that requirement unresolved.

Question 9

At a FortiSwitchOS/FortiOS 7.6 network site, an engineer observes: A conference-room controller remains on the default VLAN although its assigned access profile specifies another network. Which change MOST DIRECTLY addresses this problem without weakening the intended network design?

  1. Match the endpoint's tagging expectation by setting native and untagged VLAN behavior on the egress port.
  2. Create or verify the routed VLAN interfaces and FortiGate security policy needed for authorized communication between VLANs.
  3. Correct the native VLAN on the user-facing port so untagged frames enter the intended endpoint VLAN.
  4. Add the required tagged VLAN to the allowed list on each relevant trunk while retaining segmentation rules.

Explanation

Correct Answer

C:

For the observed condition (A conference-room controller remains on the default VLAN although its assigned access profile specifies another network), the appropriate response is to correct the native VLAN on the user-facing port so untagged frames enter the intended endpoint VLAN. The underlying risk is that changing only an uplink allowed list cannot repair a wrong access-port PVID for untagged devices. This action is targeted to native vlan on access port rather than to a different switching feature. Confirm it by checking that an untagged test client obtains an address from the correct subnet and its ingress MAC is learned in the intended VLAN.

Incorrect Answers

A:

Tagged versus untagged egress addresses another technical failure: a port that transmits 802.1Q tags to an untagged-only endpoint can break connectivity even with correct VLAN creation. The case states: A conference-room controller remains on the default VLAN although its assigned access profile specifies another network. The most direct corrective action is: correct the native VLAN on the user-facing port so untagged frames enter the intended endpoint VLAN.

B:

Inter-VLAN routing boundary addresses another technical failure: a Layer 2 VLAN alone isolates broadcasts and never creates permission to route between subnets. This choice can be useful for that problem, but it does not establish the Native VLAN on access port control being assessed here.

D:

Tagged VLAN allowed list on trunk addresses another technical failure: creating the VLAN in the database does not itself authorize its frames across every trunk hop. The required corrective action concerns Native VLAN on access port; a passing result for this alternative could leave that requirement unresolved.

Question 10

An operations team investigates this FortiSwitch 7.6 situation: A conference-room controller remains on the default VLAN although its assigned access profile specifies another network. Select TWO complementary measures: the corrective action AND evidence that it worked.

  1. Match the endpoint's tagging expectation by setting native and untagged VLAN behavior on the egress port.
  2. Create or verify the routed VLAN interfaces and FortiGate security policy needed for authorized communication between VLANs.
  3. A tagged probe traverses the intended trunk path and the VLAN appears on both ends with consistent membership.
  4. Correct the native VLAN on the user-facing port so untagged frames enter the intended endpoint VLAN.
  5. An untagged test client obtains an address from the correct subnet and its ingress MAC is learned in the intended VLAN.

Explanation

Correct Answer

D:

For the observed condition (A conference-room controller remains on the default VLAN although its assigned access profile specifies another network), the appropriate response is to correct the native VLAN on the user-facing port so untagged frames enter the intended endpoint VLAN. The underlying risk is that changing only an uplink allowed list cannot repair a wrong access-port PVID for untagged devices. This action is targeted to native vlan on access port rather than to a different switching feature. Confirm it by checking that an untagged test client obtains an address from the correct subnet and its ingress MAC is learned in the intended VLAN.

E:

The relevant acceptance proof for this incident (A conference-room controller remains on the default VLAN although its assigned access profile specifies another network) is: An untagged test client obtains an address from the correct subnet and its ingress MAC is learned in the intended VLAN. That observation tests the same failure path that prompted the change, not merely whether a physical link is up. It also helps rule out the known alternative risk: Changing only an uplink allowed list cannot repair a wrong access-port PVID for untagged devices. Retain the documented evidence after applying the associated correction: Correct the native VLAN on the user-facing port so untagged frames enter the intended endpoint VLAN.

Incorrect Answers

A:

Tagged versus untagged egress addresses another technical failure: a port that transmits 802.1Q tags to an untagged-only endpoint can break connectivity even with correct VLAN creation. The case states: A conference-room controller remains on the default VLAN although its assigned access profile specifies another network. The most direct paired action and test is: correct the native VLAN on the user-facing port so untagged frames enter the intended endpoint VLAN.

B:

Inter-VLAN routing boundary addresses another technical failure: a Layer 2 VLAN alone isolates broadcasts and never creates permission to route between subnets. This choice can be useful for that problem, but it does not establish the Native VLAN on access port control being assessed here.

C:

Tagged VLAN allowed list on trunk would demonstrate or implement: A tagged probe traverses the intended trunk path and the VLAN appears on both ends with consistent membership. This case instead tests Native VLAN on access port; the choice measures or changes another part of the system.

Fortinet NSE 5 - FortiSwitch 7.6 Administrator (NSE5_FSW_AD-7.6) Practice Tests