mcAfee Secure Website
23

CompTIA XK0-006 Bundle

Exam Code: XK0-006

Exam Name CompTIA Linux+

Certification Provider: CompTIA

Corresponding Certification: CompTIA Linux+

XK0-006 Training Materials $19.99

Reliable & Actual Study Materials for XK0-006 Exam Success

The Latest XK0-006 Exam Questions as Experienced in the Actual Test!

  • 24
    Questions & Answers

    XK0-006 Questions & Answers

    160 Questions & Answers

    Includes questions types found on actual exam such as drag and drop, simulation, type in, and fill in the blank.

  • exam =30
    Study Guide

    XK0-006 Study Guide

    1297 PDF Pages

    Study Guide developed by industry experts who have written exams in the past. They are technology-specific IT certification researchers with at least a decade of experience at Fortune 500 companies.

exam =32

CompTIA Linux+ (XK0-006) Practice Tests

Guarantee

Satisfaction Guaranteed

Pass4sure has a remarkable CompTIA Candidate Success record. We're confident of our products and provide no hassle product exchange. That's how confident we are!

99.3% Pass Rate
Total Cost: $154.98
Bundle Price: $134.99

Purchase Individually

  • exam =34
    Questions & Answers

    Questions & Answers

    160 Questions

    $124.99
    exam =35
  • exam =36
    Study Guide

    Study Guide

    1297 PDF Pages

    $29.99

CompTIA XK0-006 Practice Test 60

Question 590

A Linux administrator evaluates: A Linux alert reports a full filesystem but engineers must distinguish block exhaustion from inode exhaustion. Select TWO complementary answers: the most suitable corrective action AND the evidence proving it worked.

  1. Compare df -h and df -i, locate directories with excessive small-file creation and remediate safely according to retention policy.
  2. Inode utilization returns below the operational threshold and the application creates a new file successfully.
  3. Differentiate SSH host key verification, user authorized-key permissions and TLS endpoint certificate errors using targeted client and server evidence.
  4. The service listens on the intended interface and a permitted remote connection succeeds while an unapproved source remains blocked.
  5. Turning SELinux off or using chmod 777 cannot reliably solve a labeling issue and can weaken host security.

Explanation

Correct Answers

A:

The observed Linux condition is: A Linux alert reports a full filesystem but engineers must distinguish block exhaustion from inode exhaustion. The recommended direct administrative response is: Compare df -h and df -i, locate directories with excessive small-file creation and remediate safely according to retention policy. The relevant failure or security risk is: A filesystem can reject new files when its inode supply is exhausted even if many data blocks remain free. Validate success with: Inode utilization returns below the operational threshold and the application creates a new file successfully.

B:

For the specific observation (A Linux alert reports a full filesystem but engineers must distinguish block exhaustion from inode exhaustion), the acceptance evidence is: Inode utilization returns below the operational threshold and the application creates a new file successfully. This verifies the action (Compare df -h and df -i, locate directories with excessive small-file creation and remediate safely according to retention policy.) rather than merely proving that an unrelated Linux tool works. It also addresses the known risk: A filesystem can reject new files when its inode supply is exhausted even if many data blocks remain free.

Incorrect Answers

C:

SSH key and certificate failure diagnosis (5.4) addresses another technical failure: Disabling strict host checks or accepting unknown certificates during an incident can mask a man-in-the-middle attack. This case instead tests Inode exhaustion versus free space; the choice measures or changes another part of the system.

D:

Listener and firewall differentiation on Linux (5.3) would demonstrate or implement: The service listens on the intended interface and a permitted remote connection succeeds while an unapproved source remains blocked. The required paired action and test concerns Inode exhaustion versus free space; a passing result for this alternative could leave that requirement unresolved.

E:

SELinux denial versus traditional permission fault (5.4) would demonstrate or implement: Turning SELinux off or using chmod 777 cannot reliably solve a labeling issue and can weaken host security. The paired-answer requirement concerns Inode exhaustion versus free space; this alternative does not provide the matching intervention and separate acceptance evidence.

Question 591

A Linux administrator investigates: An array still serves reads after one SSD fails but reports a degraded mirror state. Which action BEST addresses the specific Linux technical requirement?

  1. Differentiate SSH host key verification, user authorized-key permissions and TLS endpoint certificate errors using targeted client and server evidence.
  2. Inspect id, namei -l, stat and getfacl to diagnose effective file access, including parent directory traversal and ACL masks.
  3. Use dmesg, smart or device events where supported, /proc/mdstat and mdadm detail to distinguish failing disks from degraded array membership.
  4. Measure effective path MTU with safe probes and interface counters, then adjust supported MTU or TCP MSS settings where warranted.

Explanation

Correct Answer

C:

The observed Linux condition is: An array still serves reads after one SSD fails but reports a degraded mirror state. The recommended direct administrative response is: Use dmesg, smart or device events where supported, /proc/mdstat and mdadm detail to distinguish failing disks from degraded array membership. The relevant failure or security risk is: Assuming an array is healthy because its mount still works can hide loss of redundancy and imminent data unavailability. Validate success with: Device error evidence identifies the failed member and the supported rebuild restores array redundancy without new I/O faults.

Incorrect Answers

A:

SSH key and certificate failure diagnosis (5.4) addresses another technical failure: Disabling strict host checks or accepting unknown certificates during an incident can mask a man-in-the-middle attack. The case states: An array still serves reads after one SSD fails but reports a degraded mirror state. The most direct diagnosis is: Use dmesg, smart or device events where supported, /proc/mdstat and mdadm detail to distinguish failing disks from degraded array membership.

B:

ACL mask and directory traversal permission failures (5.4) addresses another technical failure: Granting world access to the final file may not fix a missing execute permission on a parent directory and exposes unnecessary data. This choice can be useful for that problem, but it does not establish the Degraded md RAID and storage I/O failure isolation control being assessed here.

D:

MTU and path fragmentation troubleshooting (5.3) addresses another technical failure: An encapsulation overhead mismatch can blackhole larger packets even when small ICMP tests pass. The required diagnosis concerns Degraded md RAID and storage I/O failure isolation; a passing result for this alternative could leave that requirement unresolved.

Question 592

In the post-change validation, the team sees: An array still serves reads after one SSD fails but reports a degraded mirror state. Which evidence MOST directly confirms the appropriate correction succeeded?

  1. Comparable workload samples isolate the actual runnable or blocked bottleneck and show improved response after a measured correction.
  2. Device error evidence identifies the failed member and the supported rebuild restores array redundancy without new I/O faults.
  3. The service listens on the intended interface and a permitted remote connection succeeds while an unapproved source remains blocked.
  4. The approved client authenticates to the verified host with a valid key or certificate and rejects an untrusted identity.

Explanation

Correct Answer

B:

For the specific observation (An array still serves reads after one SSD fails but reports a degraded mirror state), the acceptance evidence is: Device error evidence identifies the failed member and the supported rebuild restores array redundancy without new I/O faults. This verifies the action (Use dmesg, smart or device events where supported, /proc/mdstat and mdadm detail to distinguish failing disks from degraded array membership.) rather than merely proving that an unrelated Linux tool works. It also addresses the known risk: Assuming an array is healthy because its mount still works can hide loss of redundancy and imminent data unavailability.

Incorrect Answers

A:

CPU saturation versus load-average analysis (5.5) would demonstrate or implement: Comparable workload samples isolate the actual runnable or blocked bottleneck and show improved response after a measured correction. The case states: An array still serves reads after one SSD fails but reports a degraded mirror state. The most direct evidence is: Device error evidence identifies the failed member and the supported rebuild restores array redundancy without new I/O faults.

C:

Listener and firewall differentiation on Linux (5.3) would demonstrate or implement: The service listens on the intended interface and a permitted remote connection succeeds while an unapproved source remains blocked. This case instead tests Degraded md RAID and storage I/O failure isolation; the choice measures or changes another part of the system.

D:

SSH key and certificate failure diagnosis (5.4) would demonstrate or implement: The approved client authenticates to the verified host with a valid key or certificate and rejects an untrusted identity. The required evidence concerns Degraded md RAID and storage I/O failure isolation; a passing result for this alternative could leave that requirement unresolved.

Question 593

A change review on a Linux server identifies: A server logs repeated block I/O errors for one member of an otherwise mounted md device. Which action BEST addresses the specific Linux technical requirement?

  1. Use top, vmstat, pidstat and per-core utilization to distinguish CPU saturation, blocked tasks and load-average patterns before tuning.
  2. Confirm service socket state with ss, test local and remote TCP reachability, and inspect nftables or firewalld rules to isolate the blocking layer.
  3. Differentiate SSH host key verification, user authorized-key permissions and TLS endpoint certificate errors using targeted client and server evidence.
  4. Use dmesg, smart or device events where supported, /proc/mdstat and mdadm detail to distinguish failing disks from degraded array membership.

Explanation

Correct Answer

D:

The observed Linux condition is: A server logs repeated block I/O errors for one member of an otherwise mounted md device. The recommended direct administrative response is: Use dmesg, smart or device events where supported, /proc/mdstat and mdadm detail to distinguish failing disks from degraded array membership. The relevant failure or security risk is: Assuming an array is healthy because its mount still works can hide loss of redundancy and imminent data unavailability. Validate success with: Device error evidence identifies the failed member and the supported rebuild restores array redundancy without new I/O faults.

Incorrect Answers

A:

CPU saturation versus load-average analysis (5.5) addresses another technical failure: A high load average alone does not prove CPUs are busy, because tasks in uninterruptible I/O wait may contribute. The case states: A server logs repeated block I/O errors for one member of an otherwise mounted md device. The most direct corrective action is: Use dmesg, smart or device events where supported, /proc/mdstat and mdadm detail to distinguish failing disks from degraded array membership.

B:

Listener and firewall differentiation on Linux (5.3) addresses another technical failure: Opening a port cannot help if the daemon only binds loopback or is stopped, and a listening socket alone cannot prove external access. This choice can be useful for that problem, but it does not establish the Degraded md RAID and storage I/O failure isolation control being assessed here.

C:

SSH key and certificate failure diagnosis (5.4) addresses another technical failure: Disabling strict host checks or accepting unknown certificates during an incident can mask a man-in-the-middle attack. This case instead tests Degraded md RAID and storage I/O failure isolation; the choice measures or changes another part of the system.

Question 594

A Linux administrator reviews a reported issue: A server logs repeated block I/O errors for one member of an otherwise mounted md device. Which failure mode or risk is MOST relevant to this condition?

  1. An encapsulation overhead mismatch can blackhole larger packets even when small ICMP tests pass.
  2. Assuming an array is healthy because its mount still works can hide loss of redundancy and imminent data unavailability.
  3. Granting world access to the final file may not fix a missing execute permission on a parent directory and exposes unnecessary data.
  4. Treating file cache as unavailable RAM or blindly disabling swap can obscure the application responsible for OOM kills.

Explanation

Correct Answer

B:

The reported situation (A server logs repeated block I/O errors for one member of an otherwise mounted md device) most directly creates this failure risk: Assuming an array is healthy because its mount still works can hide loss of redundancy and imminent data unavailability. The corresponding safe response is: Use dmesg, smart or device events where supported, /proc/mdstat and mdadm detail to distinguish failing disks from degraded array membership. An appropriate outcome check is: Device error evidence identifies the failed member and the supported rebuild restores array redundancy without new I/O faults.

Incorrect Answers

A:

MTU and path fragmentation troubleshooting (5.3) would demonstrate or implement: An encapsulation overhead mismatch can blackhole larger packets even when small ICMP tests pass. The case states: A server logs repeated block I/O errors for one member of an otherwise mounted md device. The most direct risk is: Assuming an array is healthy because its mount still works can hide loss of redundancy and imminent data unavailability.

C:

ACL mask and directory traversal permission failures (5.4) would demonstrate or implement: Granting world access to the final file may not fix a missing execute permission on a parent directory and exposes unnecessary data. This case instead tests Degraded md RAID and storage I/O failure isolation; the choice measures or changes another part of the system.

D:

Memory pressure OOM killer and swapping (5.5) would demonstrate or implement: Treating file cache as unavailable RAM or blindly disabling swap can obscure the application responsible for OOM kills. The required risk concerns Degraded md RAID and storage I/O failure isolation; a passing result for this alternative could leave that requirement unresolved.

Question 595

A production incident ticket states: A new RAID replacement drive was inserted but its resync counters never advance. Which action BEST addresses the specific Linux technical requirement?

  1. Use dmesg, smart or device events where supported, /proc/mdstat and mdadm detail to distinguish failing disks from degraded array membership.
  2. Inspect free, vmstat, /proc/meminfo and kernel OOM events to distinguish reclaimable cache, active swapping and actual memory exhaustion.
  3. Measure effective path MTU with safe probes and interface counters, then adjust supported MTU or TCP MSS settings where warranted.
  4. Inspect id, namei -l, stat and getfacl to diagnose effective file access, including parent directory traversal and ACL masks.

Explanation

Correct Answer

A:

The observed Linux condition is: A new RAID replacement drive was inserted but its resync counters never advance. The recommended direct administrative response is: Use dmesg, smart or device events where supported, /proc/mdstat and mdadm detail to distinguish failing disks from degraded array membership. The relevant failure or security risk is: Assuming an array is healthy because its mount still works can hide loss of redundancy and imminent data unavailability. Validate success with: Device error evidence identifies the failed member and the supported rebuild restores array redundancy without new I/O faults.

Incorrect Answers

B:

Memory pressure OOM killer and swapping (5.5) addresses another technical failure: Treating file cache as unavailable RAM or blindly disabling swap can obscure the application responsible for OOM kills. This choice can be useful for that problem, but it does not establish the Degraded md RAID and storage I/O failure isolation control being assessed here.

C:

MTU and path fragmentation troubleshooting (5.3) addresses another technical failure: An encapsulation overhead mismatch can blackhole larger packets even when small ICMP tests pass. This case instead tests Degraded md RAID and storage I/O failure isolation; the choice measures or changes another part of the system.

D:

ACL mask and directory traversal permission failures (5.4) addresses another technical failure: Granting world access to the final file may not fix a missing execute permission on a parent directory and exposes unnecessary data. The required corrective action concerns Degraded md RAID and storage I/O failure isolation; a passing result for this alternative could leave that requirement unresolved.

Question 596

An infrastructure engineer checks a specific situation: A new RAID replacement drive was inserted but its resync counters never advance. Which evidence MOST directly confirms the appropriate correction succeeded?

  1. Representative large and small application payloads traverse the path without fragmentation-related loss or excessive retransmits.
  2. Device error evidence identifies the failed member and the supported rebuild restores array redundancy without new I/O faults.
  3. The service listens on the intended interface and a permitted remote connection succeeds while an unapproved source remains blocked.
  4. Memory and swap metrics return within tested thresholds and the protected service survives sustained representative load.

Explanation

Correct Answer

B:

For the specific observation (A new RAID replacement drive was inserted but its resync counters never advance), the acceptance evidence is: Device error evidence identifies the failed member and the supported rebuild restores array redundancy without new I/O faults. This verifies the action (Use dmesg, smart or device events where supported, /proc/mdstat and mdadm detail to distinguish failing disks from degraded array membership.) rather than merely proving that an unrelated Linux tool works. It also addresses the known risk: Assuming an array is healthy because its mount still works can hide loss of redundancy and imminent data unavailability.

Incorrect Answers

A:

MTU and path fragmentation troubleshooting (5.3) would demonstrate or implement: Representative large and small application payloads traverse the path without fragmentation-related loss or excessive retransmits. The case states: A new RAID replacement drive was inserted but its resync counters never advance. The most direct evidence is: Device error evidence identifies the failed member and the supported rebuild restores array redundancy without new I/O faults.

C:

Listener and firewall differentiation on Linux (5.3) would demonstrate or implement: The service listens on the intended interface and a permitted remote connection succeeds while an unapproved source remains blocked. This case instead tests Degraded md RAID and storage I/O failure isolation; the choice measures or changes another part of the system.

D:

Memory pressure OOM killer and swapping (5.5) would demonstrate or implement: Memory and swap metrics return within tested thresholds and the protected service survives sustained representative load. The required evidence concerns Degraded md RAID and storage I/O failure isolation; a passing result for this alternative could leave that requirement unresolved.

Question 597

An authorized Linux operations assessment observes: An operator sees slow disk writes and attributes the problem to networking without checking mdstat or kernel errors. Which action BEST addresses the specific Linux technical requirement?

  1. Inspect free, vmstat, /proc/meminfo and kernel OOM events to distinguish reclaimable cache, active swapping and actual memory exhaustion.
  2. Measure effective path MTU with safe probes and interface counters, then adjust supported MTU or TCP MSS settings where warranted.
  3. Use dmesg, smart or device events where supported, /proc/mdstat and mdadm detail to distinguish failing disks from degraded array membership.
  4. Confirm service socket state with ss, test local and remote TCP reachability, and inspect nftables or firewalld rules to isolate the blocking layer.

Explanation

Correct Answer

C:

The observed Linux condition is: An operator sees slow disk writes and attributes the problem to networking without checking mdstat or kernel errors. The recommended direct administrative response is: Use dmesg, smart or device events where supported, /proc/mdstat and mdadm detail to distinguish failing disks from degraded array membership. The relevant failure or security risk is: Assuming an array is healthy because its mount still works can hide loss of redundancy and imminent data unavailability. Validate success with: Device error evidence identifies the failed member and the supported rebuild restores array redundancy without new I/O faults.

Incorrect Answers

A:

Memory pressure OOM killer and swapping (5.5) addresses another technical failure: Treating file cache as unavailable RAM or blindly disabling swap can obscure the application responsible for OOM kills. The case states: An operator sees slow disk writes and attributes the problem to networking without checking mdstat or kernel errors. The most direct corrective action is: Use dmesg, smart or device events where supported, /proc/mdstat and mdadm detail to distinguish failing disks from degraded array membership.

B:

MTU and path fragmentation troubleshooting (5.3) addresses another technical failure: An encapsulation overhead mismatch can blackhole larger packets even when small ICMP tests pass. This choice can be useful for that problem, but it does not establish the Degraded md RAID and storage I/O failure isolation control being assessed here.

D:

Listener and firewall differentiation on Linux (5.3) addresses another technical failure: Opening a port cannot help if the daemon only binds loopback or is stopped, and a listening socket alone cannot prove external access. The required corrective action concerns Degraded md RAID and storage I/O failure isolation; a passing result for this alternative could leave that requirement unresolved.

Question 598

In a controlled system validation, the observation is: An operator sees slow disk writes and attributes the problem to networking without checking mdstat or kernel errors. Which failure mode or risk is MOST relevant to this condition?

  1. Turning SELinux off or using chmod 777 cannot reliably solve a labeling issue and can weaken host security.
  2. Assuming an array is healthy because its mount still works can hide loss of redundancy and imminent data unavailability.
  3. A high load average alone does not prove CPUs are busy, because tasks in uninterruptible I/O wait may contribute.
  4. An encapsulation overhead mismatch can blackhole larger packets even when small ICMP tests pass.

Explanation

Correct Answer

B:

The reported situation (An operator sees slow disk writes and attributes the problem to networking without checking mdstat or kernel errors) most directly creates this failure risk: Assuming an array is healthy because its mount still works can hide loss of redundancy and imminent data unavailability. The corresponding safe response is: Use dmesg, smart or device events where supported, /proc/mdstat and mdadm detail to distinguish failing disks from degraded array membership. An appropriate outcome check is: Device error evidence identifies the failed member and the supported rebuild restores array redundancy without new I/O faults.

Incorrect Answers

A:

SELinux denial versus traditional permission fault (5.4) would demonstrate or implement: Turning SELinux off or using chmod 777 cannot reliably solve a labeling issue and can weaken host security. The case states: An operator sees slow disk writes and attributes the problem to networking without checking mdstat or kernel errors. The most direct evidence is: Assuming an array is healthy because its mount still works can hide loss of redundancy and imminent data unavailability.

C:

CPU saturation versus load-average analysis (5.5) would demonstrate or implement: A high load average alone does not prove CPUs are busy, because tasks in uninterruptible I/O wait may contribute. This case instead tests Degraded md RAID and storage I/O failure isolation; the choice measures or changes another part of the system.

D:

MTU and path fragmentation troubleshooting (5.3) would demonstrate or implement: An encapsulation overhead mismatch can blackhole larger packets even when small ICMP tests pass. The required evidence concerns Degraded md RAID and storage I/O failure isolation; a passing result for this alternative could leave that requirement unresolved.

Question 599

During a planned service review, engineers find: A storage operations ticket asks which physical disk generated errors before a replacement is authorized. Which action BEST addresses the specific Linux technical requirement?

  1. Use top, vmstat, pidstat and per-core utilization to distinguish CPU saturation, blocked tasks and load-average patterns before tuning.
  2. Measure effective path MTU with safe probes and interface counters, then adjust supported MTU or TCP MSS settings where warranted.
  3. Use dmesg, smart or device events where supported, /proc/mdstat and mdadm detail to distinguish failing disks from degraded array membership.
  4. Correlate AVC records, file labels and discretionary file ownership before selecting a context-specific SELinux remediation.

Explanation

Correct Answer

C:

The observed Linux condition is: A storage operations ticket asks which physical disk generated errors before a replacement is authorized. The recommended direct administrative response is: Use dmesg, smart or device events where supported, /proc/mdstat and mdadm detail to distinguish failing disks from degraded array membership. The relevant failure or security risk is: Assuming an array is healthy because its mount still works can hide loss of redundancy and imminent data unavailability. Validate success with: Device error evidence identifies the failed member and the supported rebuild restores array redundancy without new I/O faults.

Incorrect Answers

A:

CPU saturation versus load-average analysis (5.5) addresses another technical failure: A high load average alone does not prove CPUs are busy, because tasks in uninterruptible I/O wait may contribute. The case states: A storage operations ticket asks which physical disk generated errors before a replacement is authorized. The most direct corrective action is: Use dmesg, smart or device events where supported, /proc/mdstat and mdadm detail to distinguish failing disks from degraded array membership.

B:

MTU and path fragmentation troubleshooting (5.3) addresses another technical failure: An encapsulation overhead mismatch can blackhole larger packets even when small ICMP tests pass. This choice can be useful for that problem, but it does not establish the Degraded md RAID and storage I/O failure isolation control being assessed here.

D:

SELinux denial versus traditional permission fault (5.4) addresses another technical failure: Turning SELinux off or using chmod 777 cannot reliably solve a labeling issue and can weaken host security. The required corrective action concerns Degraded md RAID and storage I/O failure isolation; a passing result for this alternative could leave that requirement unresolved.

Question 600

A Linux administrator evaluates: A storage operations ticket asks which physical disk generated errors before a replacement is authorized. Select TWO complementary answers: the most suitable corrective action AND the evidence proving it worked.

  1. Use dmesg, smart or device events where supported, /proc/mdstat and mdadm detail to distinguish failing disks from degraded array membership.
  2. An encapsulation overhead mismatch can blackhole larger packets even when small ICMP tests pass.
  3. Inspect id, namei -l, stat and getfacl to diagnose effective file access, including parent directory traversal and ACL masks.
  4. Under a comparable transaction workload, measured await, utilization and application latency improve without new I/O errors.
  5. Device error evidence identifies the failed member and the supported rebuild restores array redundancy without new I/O faults.

Explanation

Correct Answers

A:

The observed Linux condition is: A storage operations ticket asks which physical disk generated errors before a replacement is authorized. The recommended direct administrative response is: Use dmesg, smart or device events where supported, /proc/mdstat and mdadm detail to distinguish failing disks from degraded array membership. The relevant failure or security risk is: Assuming an array is healthy because its mount still works can hide loss of redundancy and imminent data unavailability. Validate success with: Device error evidence identifies the failed member and the supported rebuild restores array redundancy without new I/O faults.

E:

For the specific observation (A storage operations ticket asks which physical disk generated errors before a replacement is authorized), the acceptance evidence is: Device error evidence identifies the failed member and the supported rebuild restores array redundancy without new I/O faults. This verifies the action (Use dmesg, smart or device events where supported, /proc/mdstat and mdadm detail to distinguish failing disks from degraded array membership.) rather than merely proving that an unrelated Linux tool works. It also addresses the known risk: Assuming an array is healthy because its mount still works can hide loss of redundancy and imminent data unavailability.

Incorrect Answers

B:

MTU and path fragmentation troubleshooting (5.3) would demonstrate or implement: An encapsulation overhead mismatch can blackhole larger packets even when small ICMP tests pass. This choice can be useful for that problem, but it does not establish the Degraded md RAID and storage I/O failure isolation control being assessed here.

C:

ACL mask and directory traversal permission failures (5.4) addresses another technical failure: Granting world access to the final file may not fix a missing execute permission on a parent directory and exposes unnecessary data. This case instead tests Degraded md RAID and storage I/O failure isolation; the choice measures or changes another part of the system.

D:

Disk IO wait and throughput bottleneck diagnosis (5.5) would demonstrate or implement: Under a comparable transaction workload, measured await, utilization and application latency improve without new I/O errors. The required paired action and test concerns Degraded md RAID and storage I/O failure isolation; a passing result for this alternative could leave that requirement unresolved.