mcAfee Secure Website
23

CompTIA CAS-005 Bundle

Exam Code: CAS-005

Exam Name CompTIA SecurityX

Certification Provider: CompTIA

Corresponding Certification: CASP

CAS-005 Training Materials $44.99

Reliable & Actual Study Materials for CAS-005 Exam Success

The Latest CAS-005 Exam Questions as Experienced in the Actual Test!

  • 24
    Questions & Answers

    CAS-005 Questions & Answers

    482 Questions & Answers

    Includes questions types found on actual exam such as drag and drop, simulation, type in, and fill in the blank.

  • 25
    CAS-005 Video Course

    CAS-005 Training Course

    180 Video Lectures

    Based on Real Life Scenarios which you will encounter in exam and learn by working with real equipment.

  • exam =30
    Study Guide

    CAS-005 Study Guide

    903 PDF Pages

    Study Guide developed by industry experts who have written exams in the past. They are technology-specific IT certification researchers with at least a decade of experience at Fortune 500 companies.

exam =32

CompTIA SecurityX (CAS-005) Practice Tests

Guarantee

Satisfaction Guaranteed

Pass4sure has a remarkable CompTIA Candidate Success record. We're confident of our products and provide no hassle product exchange. That's how confident we are!

99.3% Pass Rate
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • exam =34
    Questions & Answers

    Questions & Answers

    482 Questions

    $124.99
    exam =35
  • exam =37
    CAS-005 Video Course

    Training Course

    180 Video Lectures

    $39.99
  • exam =36
    Study Guide

    Study Guide

    903 PDF Pages

    $29.99

CompTIA CAS-005 Practice Test 39

Question 380

A decommissioned laptop has a self-encrypting drive; the asset team formats the filesystem but does not invalidate the hardware encryption key before resale. What post-change result would most convincingly validate the intended risk reduction?

  1. Independent read attempts cannot access prior encrypted content after key destruction
  2. The disk appears empty while the prior encryption key remains usable
  3. Operating-system file tools show no partitions while the key still decrypts data
  4. A decommissioned disk boots to an empty filesystem but still has the old key

Explanation

Correct Answer

A:

Independent read attempts cannot access prior encrypted content after key destruction. This checks the risk-changing outcome, rather than showing only that a ticket closed. The decisive mechanism is that secure sanitization depends on erasing the effective encryption key. Compare the observed result to the initial evidence and preserve the test record.

Incorrect Answers

B:

The disk appears empty still permits the prior encryption key remains usable. The actual failure or design condition is A logical format does not guarantee cryptographic destruction of prior data.

C:

Operating-system file tools show no partitions still permits the key still decrypts data. What the present question requires instead is Use verified device-supported cryptographic erase before disposal.

D:

A decommissioned disk boots to an empty filesystem still permits still has the old key. The source-specific test or observation is Independent read attempts cannot access prior encrypted content after key destruction.

Question 381

A decommissioned laptop has a self-encrypting drive; the asset team formats the filesystem but does not invalidate the hardware encryption key before resale. Which caution matters most when interpreting this scenario or its proposed treatment?

  1. A quick format is functionally identical to destruction of a drive's data key
  2. Crypto erase requires confidence the data was actually encrypted under destroyed keys
  3. Deleted filenames prove an SED's encryption key is no longer recoverable
  4. Self-encrypting drives automatically rotate keys whenever users format volumes

Explanation

Correct Answer

B:

Crypto erase requires confidence the data was actually encrypted under destroyed keys. This qualification prevents the conclusion from exceeding the evidence. The mechanism is that secure sanitization depends on erasing the effective encryption key. Use drive sanitization command results and key change verification to resolve the remaining uncertainty.

Incorrect Answers

A:

The alternative claims: “A quick format is functionally identical to destruction of a drive's data key”. The controlling technical principle here is Secure sanitization depends on erasing the effective encryption key.

C:

The alternative claims: “Deleted filenames prove an SED's encryption key is no longer recoverable”. What the present question requires instead is Use verified device-supported cryptographic erase before disposal.

D:

The alternative claims: “Self-encrypting drives automatically rotate keys whenever users format volumes”. The source-specific test or observation is Independent read attempts cannot access prior encrypted content after key destruction.

Question 382

A workstation fleet uses USB allowlists based only on vendor identifiers; a malicious programmable device presents as a trusted keyboard and issues unauthorized commands. What assessment best explains the observed weakness without assuming facts not in evidence?

  1. A claimed trusted USB vendor ID proves the device implements only approved behavior
  2. USB device identity by claimed vendor ID is insufficient against emulated peripherals
  3. A USB device's keyboard class guarantees it cannot inject unauthorized commands
  4. A signed host OS guarantees trusted behavior from any attached USB keyboard

Explanation

Correct Answer

B:

USB device identity by claimed vendor ID is insufficient against emulated peripherals. The stated facts point to this bounded conclusion: Hardware peripheral trust needs authenticated function policy where feasible. To challenge the conclusion rather than guess at causation, inspect USB enumeration logs, device-control rules and execution telemetry. The observation does not by itself establish an attacker identity or every downstream impact.

Incorrect Answers

A:

A USB vendor identifier is an unauthenticated claim about the maker, not proof of permitted device behavior. A programmable peripheral can spoof the vendor value and operate outside the intended allowlist.

C:

USB HID keyboard class identifies an interface type, not whether keystrokes were authorized by the user. A malicious programmable keyboard can inject commands despite presenting a conventional class code.

D:

The operating system signature attests to host software provenance; it cannot attest to the firmware or behavior of a connected USB keyboard. Enforce a narrower peripheral trust boundary.

Question 383

A water facility's PLCs may reset when probed with an active vulnerability scanner, and operators require continuous chlorine dosing. What assessment best explains the observed weakness without assuming facts not in evidence?

  1. Higher active scan coverage always outweighs the risk of controller process interruption
  2. Active security scanning can create an unacceptable physical safety risk
  3. An IT vulnerability score establishes that scanning the PLC is safe at full production load
  4. Vulnerability scanning cannot affect plant operations because it only sends read requests

Explanation

Correct Answer

B:

Active security scanning can create an unacceptable physical safety risk. The stated facts point to this bounded conclusion: OT security treatment starts with process safety and device constraints. To challenge the conclusion rather than guess at causation, inspect OT asset register, vendor advisory and passive flow inventory. The observation does not by itself establish an attacker identity or every downstream impact.

Incorrect Answers

A:

The alternative claims: “Higher active scan coverage always outweighs the risk of controller process interruption”. The controlling technical principle here is OT security treatment starts with process safety and device constraints.

C:

The alternative claims: “An IT vulnerability score establishes that scanning the PLC is safe at full production load”. What the present question requires instead is Use passive assessment and engineer-approved maintenance testing windows.

D:

This proposal relies on the unproven premise that it only sends read requests. The source-specific test or observation is Critical dosing remains stable during monitoring and risk findings are recorded.

Question 384

A water facility's PLCs may reset when probed with an active vulnerability scanner, and operators require continuous chlorine dosing. Which investigative record set most directly tests the cause described?

  1. OT asset register, vendor advisory and passive flow inventory
  2. IT network scanner output without PLC vendor and operations safety constraints
  3. Scanner discovery output without process engineering test approvals
  4. Active scan duration records without controller response stability and process variables

Explanation

Correct Answer

A:

OT asset register, vendor advisory and passive flow inventory. These artifacts directly test the relevant path: OT security treatment starts with process safety and device constraints. Preserve original records and correlate the affected principal, component and event sequence. The investigative boundary remains: IT scan profiles should not be applied blindly to safety-critical controllers.

Incorrect Answers

B:

IT network scanner output omits PLC vendor and operations safety constraints. The actual failure or design condition is Active security scanning can create an unacceptable physical safety risk.

C:

Scanner discovery output omits process engineering test approvals. What the present question requires instead is Use passive assessment and engineer-approved maintenance testing windows.

D:

Active scan duration records omits controller response stability and process variables. The source-specific test or observation is Critical dosing remains stable during monitoring and risk findings are recorded.

Question 385

A water facility's PLCs may reset when probed with an active vulnerability scanner, and operators require continuous chlorine dosing. Which control change most directly addresses the stated problem?

  1. Run aggressive authenticated scans during peak production to maximize coverage
  2. Schedule aggressive production PLC scans without operator review
  3. Use passive assessment and engineer-approved maintenance testing windows
  4. Use a network maintenance window selected by IT without plant safety operators

Explanation

Correct Answer

C:

Use passive assessment and engineer-approved maintenance testing windows. The intervention addresses the observed exposure because OT security treatment starts with process safety and device constraints. It should be implemented with change authorization and the service-specific safety constraints of this case. Confirm the result by checking whether critical dosing remains stable during monitoring and risk findings are recorded.

Incorrect Answers

A:

The alternative claims: “Run aggressive authenticated scans during peak production to maximize coverage”. The controlling technical principle here is OT security treatment starts with process safety and device constraints.

B:

Schedule aggressive production PLC scans omits operator review. The actual failure or design condition is Active security scanning can create an unacceptable physical safety risk.

D:

Use a network maintenance window selected by IT omits plant safety operators. The source-specific test or observation is Critical dosing remains stable during monitoring and risk findings are recorded.

Question 386

A water facility's PLCs may reset when probed with an active vulnerability scanner, and operators require continuous chlorine dosing. What post-change result would most convincingly validate the intended risk reduction?

  1. More CVEs appear in reports while chlorine dosing is interrupted
  2. Critical dosing remains stable during monitoring and risk findings are recorded
  3. The scan completes and finds ports but interrupts a critical dosing controller
  4. The plant discovers vulnerable devices but dosing interruptions create greater risk

Explanation

Correct Answer

B:

Critical dosing remains stable during monitoring and risk findings are recorded. This checks the risk-changing outcome, rather than showing only that a ticket closed. The decisive mechanism is that oT security treatment starts with process safety and device constraints. Compare the observed result to the initial evidence and preserve the test record.

Incorrect Answers

A:

More CVEs appear in reports still permits chlorine dosing is interrupted. The controlling technical principle here is OT security treatment starts with process safety and device constraints.

C:

The scan completes and finds ports still permits interrupts a critical dosing controller. What the present question requires instead is Use passive assessment and engineer-approved maintenance testing windows.

D:

The plant discovers vulnerable devices still permits dosing interruptions create greater risk. The source-specific test or observation is Critical dosing remains stable during monitoring and risk findings are recorded.

Question 387

A water facility's PLCs may reset when probed with an active vulnerability scanner, and operators require continuous chlorine dosing. Which caution matters most when interpreting this scenario or its proposed treatment?

  1. Any security scanner is safe on all industrial controller protocols
  2. IT scan profiles should not be applied blindly to safety-critical controllers
  3. A passive scan is always identical to a high-volume active probe
  4. Production PLCs are always capable of handling enterprise IT scanning defaults

Explanation

Correct Answer

B:

IT scan profiles should not be applied blindly to safety-critical controllers. This qualification prevents the conclusion from exceeding the evidence. The mechanism is that oT security treatment starts with process safety and device constraints. Use oT asset register, vendor advisory and passive flow inventory to resolve the remaining uncertainty.

Incorrect Answers

A:

The alternative claims: “Any security scanner is safe on all industrial controller protocols”. The controlling technical principle here is OT security treatment starts with process safety and device constraints.

C:

The alternative claims: “A passive scan is always identical to a high-volume active probe”. What the present question requires instead is Use passive assessment and engineer-approved maintenance testing windows.

D:

The alternative claims: “Production PLCs are always capable of handling enterprise IT scanning defaults”. The source-specific test or observation is Critical dosing remains stable during monitoring and risk findings are recorded.

Question 388

A transport authority bridges an obsolete serial signal controller to a cloud dashboard through unrestricted remote management on the public internet. What assessment best explains the observed weakness without assuming facts not in evidence?

  1. An obscure serial protocol is sufficient isolation once bridged through public cloud
  2. Cloud exposure bypasses the assumed isolation of legacy control equipment
  3. Serial-controller authentication is unnecessary because the dashboard uses TLS
  4. An encrypted remote dashboard means the legacy controller administration API is inaccessible publicly

Explanation

Correct Answer

B:

Cloud exposure bypasses the assumed isolation of legacy control equipment. The stated facts point to this bounded conclusion: Legacy OT exposure must be evaluated at modern connectivity bridges. To challenge the conclusion rather than guess at causation, inspect Gateway routes, management ACLs and remote access audit logs. The observation does not by itself establish an attacker identity or every downstream impact.

Incorrect Answers

A:

The alternative claims: “An obscure serial protocol is sufficient isolation once bridged through public cloud”. The controlling technical principle here is Legacy OT exposure must be evaluated at modern connectivity bridges.

C:

This proposal relies on the unproven premise that the dashboard uses TLS. What the present question requires instead is Restrict gateway management through authenticated segmented jump access.

D:

The alternative claims: “An encrypted remote dashboard means the legacy controller administration API is inaccessible publicly”. The source-specific test or observation is External scans cannot reach signal-control administration while approved engineers can.

Question 389

A transport authority bridges an obsolete serial signal controller to a cloud dashboard through unrestricted remote management on the public internet. Which investigative record set most directly tests the cause described?

  1. Serial device documentation without public gateway ACL and management path tests
  2. Gateway routes, management ACLs and remote access audit logs
  3. Cloud login status without public reachability to the serial gateway interface
  4. Cloud service certificate without testing gateway management reachability and access policy

Explanation

Correct Answer

B:

Gateway routes, management ACLs and remote access audit logs. These artifacts directly test the relevant path: Legacy OT exposure must be evaluated at modern connectivity bridges. Preserve original records and correlate the affected principal, component and event sequence. The investigative boundary remains: A private serial protocol is not security when encapsulated over public networks.

Incorrect Answers

A:

Serial device documentation omits public gateway ACL and management path tests. The controlling technical principle here is Legacy OT exposure must be evaluated at modern connectivity bridges.

C:

Cloud login status omits public reachability to the serial gateway interface. What the present question requires instead is Restrict gateway management through authenticated segmented jump access.

D:

Cloud service certificate omits testing gateway management reachability and access policy. The source-specific test or observation is External scans cannot reach signal-control administration while approved engineers can.

Question 390

A transport authority bridges an obsolete serial signal controller to a cloud dashboard through unrestricted remote management on the public internet. Which control change most directly addresses the stated problem?

  1. Rely on the obscurity of the serial protocol and keep public management open
  2. Leave the cloud management port open because only trained operators know the protocol
  3. Restrict gateway management through authenticated segmented jump access
  4. Hide the public endpoint hostname but retain permissive remote management ACLs

Explanation

Correct Answer

C:

Restrict gateway management through authenticated segmented jump access. The intervention addresses the observed exposure because Legacy OT exposure must be evaluated at modern connectivity bridges. It should be implemented with change authorization and the service-specific safety constraints of this case. Confirm the result by checking whether external scans cannot reach signal-control administration while approved engineers can.

Incorrect Answers

A:

The alternative claims: “Rely on the obscurity of the serial protocol and keep public management open”. The controlling technical principle here is Legacy OT exposure must be evaluated at modern connectivity bridges.

B:

This proposal relies on the unproven premise that only trained operators know the protocol. The actual failure or design condition is Cloud exposure bypasses the assumed isolation of legacy control equipment.

D:

Hide the public endpoint hostname still permits retain permissive remote management ACLs. The source-specific test or observation is External scans cannot reach signal-control administration while approved engineers can.