mcAfee Secure Website
23

CompTIA 220-1101 Bundle

Exam Code: 220-1101

Exam Name CompTIA A+ Certification Exam: Core 1

Certification Provider: CompTIA

Corresponding Certification: CompTIA A+

220-1101 Training Materials $44.99

Reliable & Actual Study Materials for 220-1101 Exam Success

The Latest 220-1101 Exam Questions as Experienced in the Actual Test!

  • 24
    Questions & Answers

    220-1101 Questions & Answers

    519 Questions & Answers

    Includes questions types found on actual exam such as drag and drop, simulation, type in, and fill in the blank.

  • 25
    220-1101 Video Course

    220-1101 Training Course

    201 Video Lectures

    Based on Real Life Scenarios which you will encounter in exam and learn by working with real equipment.

  • exam =30
    Study Guide

    220-1101 Study Guide

    3030 PDF Pages

    Study Guide developed by industry experts who have written exams in the past. They are technology-specific IT certification researchers with at least a decade of experience at Fortune 500 companies.

exam =32

CompTIA A+ Certification Exam: Core 1 (220-1101) Practice Tests

Guarantee

Satisfaction Guaranteed

Pass4sure has a remarkable CompTIA Candidate Success record. We're confident of our products and provide no hassle product exchange. That's how confident we are!

99.3% Pass Rate
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • exam =34
    Questions & Answers

    Questions & Answers

    519 Questions

    $124.99
    exam =35
  • exam =37
    220-1101 Video Course

    Training Course

    201 Video Lectures

    $39.99
  • exam =36
    Study Guide

    Study Guide

    3030 PDF Pages

    $29.99

CompTIA 220-1101 Practice Test 91

Question 900

A desktop crashes under heavy load and CPU temperature rises sharply after a heatsink replacement. Which technical explanation most directly supports the recommended response?

  1. Thermal contact and heat transfer are required for CPU stability.
  2. Secure Boot verifies boot component signatures when configured correctly.
  3. RAID 10 combines striping and mirroring for performance with redundancy.
  4. SODIMMs have a smaller form factor than desktop DIMMs.

Explanation

Correct Answer

A:

Reseat the compatible cooler, ensure proper thermal interface and fan operation. Temperature stays within specification during a controlled load test.

Incorrect Answers

B:

Enable supported UEFI Secure Boot with appropriately signed boot components and confirm policy compatibility. Reseat the compatible cooler, ensure proper thermal interface and fan operation.

C:

Select a supported RAID 10 configuration with independent backups. Thermal contact and heat transfer are required for CPU stability.

D:

Order the correct laptop SODIMM type and verify generation and capacity support. Temperature stays within specification during a controlled load test.

Question 901

At Elm service depot, a scheduled repair describes the following separate device or service incident: A computer shows 'boot device not found' after an internal SSD cable was disturbed during cleaning. Which technical explanation most directly supports the recommended response?

  1. Protected write-back cache may be restricted when backup power is unavailable.
  2. A damaged charging connector may cause intermittent power contact.
  3. Loose storage connections can mimic a failed or missing boot device.
  4. Reproducible evidence helps distinguish operating conditions from speculation.

Explanation

Correct Answer

C:

Inspect the drive's data/power connections and firmware device detection before reinstalling software. Firmware detects the SSD and the installed system boots without data loss.

Incorrect Answers

A:

Service the approved cache-protection component and verify policy after replacement. Inspect the drive's data/power connections and firmware device detection before reinstalling software.

B:

Inspect the charging port and cable for physical damage and perform approved port repair. Loose storage connections can mimic a failed or missing boot device.

D:

Ask for temperature, load and operating conditions, then reproduce the symptom with safe diagnostics. Inspect the drive's data/power connections and firmware device detection before reinstalling software.

Question 902

A small data server needs speed and protection against one disk failure using four matched drives. Which response would most directly address this requirement while respecting the described facts?

  1. Configure supported RAID 1 mirroring with verified backups, not a striped-only RAID 0 set.
  2. Use a compatible automatic document feeder and appropriate scan settings.
  3. Select a supported RAID 10 configuration with independent backups.
  4. Enable supported Intel VT-x or AMD-V virtualization in firmware and verify host support.

Explanation

Correct Answer

C:

RAID 10 combines striping and mirroring for performance with redundancy. The array remains functional under a qualified single-drive failure test and delivers acceptable read/write performance.

Incorrect Answers

A:

RAID 1 mirrors data for single-disk fault tolerance but is not a substitute for backup. RAID 10 combines striping and mirroring for performance with redundancy.

B:

An ADF supports document batch scanning; a flatbed is better for fragile items. The array remains functional under a qualified single-drive failure test and delivers acceptable read/write performance.

D:

Hardware-assisted virtualization must be exposed by firmware for many hypervisors. RAID 10 combines striping and mirroring for performance with redundancy.

Question 903

At Cedar laboratory, a preventive-maintenance review describes the following separate device or service incident: A spinning hard disk clicks repeatedly and SMART reports rapidly increasing reallocated-sector errors. Which technical explanation most directly supports the recommended response?

  1. Mechanical clicks with SMART degradation indicate possible impending storage failure.
  2. Protected write-back cache may be restricted when backup power is unavailable.
  3. Client-specific antenna or radio faults can exist despite a healthy access point.
  4. Verification and documentation are part of a complete troubleshooting cycle.

Explanation

Correct Answer

A:

Protect data promptly using an approved backup or recovery process and replace the failing drive. A replacement drive passes diagnostics and restored data checks.

Incorrect Answers

B:

Service the approved cache-protection component and verify policy after replacement. Protect data promptly using an approved backup or recovery process and replace the failing drive.

C:

Test the device's radio controls, antenna path and hardware diagnostics. Mechanical clicks with SMART degradation indicate possible impending storage failure.

D:

Run representative functional tests, check recurrence and document preventive actions. A replacement drive passes diagnostics and restored data checks.

Question 904

At Delta field office, an IT support visit describes the following separate device or service incident: A new processor powers on but a motherboard displays a CPU compatibility error despite a matching physical socket. Which observation would best confirm that the original issue was resolved?

  1. The capture application sees the external input at its supported format.
  2. After supported firmware and CPU pairing, POST completes successfully.
  3. A test receipt produces legible dark text on the paper.
  4. A two-page test document prints on front and back as specified.

Explanation

Correct Answer

B:

Socket fit does not guarantee firmware or chipset support for a CPU. Check CPU support list, chipset generation and the manufacturer's firmware requirements.

Incorrect Answers

A:

A capture card converts external video signals into host-accessible input. Check CPU support list, chipset generation and the manufacturer's firmware requirements.

C:

Direct thermal printing depends on heat-reactive paper orientation. After supported firmware and CPU pairing, POST completes successfully.

D:

Duplex printing depends on supported device mechanics and print defaults. Check CPU support list, chipset generation and the manufacturer's firmware requirements.

Question 905

Workstations on a new subnet know their IP addresses but cannot resolve internal hostnames. Which observation would best confirm that the original issue was resolved?

  1. Requests route only to healthy backends and fail over when one node is disabled.
  2. Both client groups connect on their supported bands and complete throughput tests.
  3. Field tests confirm usable throughput and tolerable round-trip latency at the site.
  4. Clients resolve and connect to a known internal host by its approved name.

Explanation

Correct Answer

D:

Name resolution is a server service distinct from DHCP address allocation. Configure a reachable internal DNS service and appropriate resolver records.

Incorrect Answers

A:

Load balancing distributes sessions and can exclude unhealthy application nodes. Name resolution is a server service distinct from DHCP address allocation.

B:

802.11 generations and RF bands differ in compatibility and capacity. Clients resolve and connect to a known internal host by its approved name.

C:

Satellite reaches places without terrestrial lines but can have latency and weather tradeoffs. Configure a reachable internal DNS service and appropriate resolver records.

Question 906

An enterprise wants two public cloud providers for resilience but needs unified identity and operations. Which technical explanation most directly supports the recommended response?

  1. IaaS exposes computing infrastructure while guest OS duties usually remain with the customer.
  2. Multi-cloud arrangements use services from multiple cloud vendors and need deliberate integration.
  3. Client virtualization can provide isolated sandboxes with controlled sharing.
  4. VM snapshots often consume differential storage as guests change.

Explanation

Correct Answer

B:

Adopt a documented multi-cloud management approach with per-provider identities and policy. A simulated provider interruption leaves the approved alternate service accessible.

Incorrect Answers

A:

Choose infrastructure as a service with the required guest administration features. A simulated provider interruption leaves the approved alternate service accessible.

C:

Use an isolated virtual machine snapshot or disposable lab environment with restricted host integration. Multi-cloud arrangements use services from multiple cloud vendors and need deliberate integration.

D:

Consolidate or prune obsolete snapshots safely and verify backup/recovery before cleanup. A simulated provider interruption leaves the approved alternate service accessible.

Question 907

At Alder branch, a helpdesk ticket describes the following separate device or service incident: A laptop loses charge quickly and its battery diagnostic reports severely reduced capacity, although the charger tests normally. Which outcome or shortcut would most clearly show that the technician has NOT addressed the problem safely?

  1. Forcing a physically mismatched module can damage the slot or antenna lead.
  2. Installing an incompatible battery creates fit or power risks without correcting the diagnostic finding.
  3. Forcing a USB-C plug into a miniUSB receptacle will damage the hardware.
  4. Disabling the phone's Wi-Fi does not necessarily clear stale Bluetooth pairing state.

Explanation

Correct Answer

B:

Battery wear is addressed by a compatible battery replacement, not by reinstalling the operating system. Replace the model-compatible battery using the service procedure and inspect for swelling.

Incorrect Answers

A:

Laptop expansion module appearance does not guarantee electrical and driver compatibility. Replace the model-compatible battery using the service procedure and inspect for swelling.

C:

Connector compatibility and supported transport must both be checked. The new battery reports healthy capacity and the laptop runs normally unplugged.

D:

Bluetooth pairing requires compatible discovery, authentication and device selection. Replace the model-compatible battery using the service procedure and inspect for swelling.

Question 908

A desktop accepts DDR4 but an inventory shelf contains only DDR5 kits from newer models. Which technical explanation most directly supports the recommended response?

  1. Memory controllers use board-specific population rules.
  2. Inkjet nozzles can clog and may need cleaning or head service.
  3. Fast storage and recoverability are separate requirements; RAID alone is not backup.
  4. DDR4 and DDR5 have different electrical requirements and keyed sockets.

Explanation

Correct Answer

D:

Choose a DDR4 module supported by the motherboard and CPU memory specifications. Firmware detects the expected capacity and a memory diagnostic passes.

Incorrect Answers

A:

Populate the first recommended slot rather than choosing an arbitrary socket. DDR4 and DDR5 have different electrical requirements and keyed sockets.

B:

Run an approved printhead cleaning cycle and nozzle diagnostic, then inspect printhead health. Firmware detects the expected capacity and a memory diagnostic passes.

C:

Use an appropriate SSD tier for the active project and schedule independent backups. Choose a DDR4 module supported by the motherboard and CPU memory specifications.

Question 909

A mobile device cannot see any wireless networks after a fall, while nearby devices connect normally. Which technical explanation most directly supports the recommended response?

  1. Client-specific antenna or radio faults can exist despite a healthy access point.
  2. High internal resistance in an aged battery can cause voltage collapse under load.
  3. Some panel technologies can exhibit persistent image retention with static content.
  4. RAID 5 can tolerate one drive failure, but degraded mode raises risk until rebuilt.

Explanation

Correct Answer

A:

Test the device's radio controls, antenna path and hardware diagnostics. The repaired device discovers and connects to known wireless networks.

Incorrect Answers

B:

Verify battery health and capacity diagnostics and replace an aged battery under approved practice. Test the device's radio controls, antenna path and hardware diagnostics.

C:

Assess display image-retention or burn-in characteristics and use an appropriate panel or maintenance remedy. Client-specific antenna or radio faults can exist despite a healthy access point.

D:

Identify the failed member precisely and replace it with a compatible disk under the vendor rebuild procedure. The repaired device discovers and connects to known wireless networks.

Question 910

At Alder branch, a helpdesk ticket describes the following separate device or service incident: A laser printer produces faint print despite correct settings and an almost-empty toner report. Which response would most directly address this requirement while respecting the described facts?

  1. Install the printer's compatible driver or correct print language such as PCL/PostScript.
  2. Test a known-good cable and inspect video ports for mechanical damage.
  3. Replace the approved toner cartridge and run print-density tests.
  4. Survey nearby access points and choose a supported less-congested channel or band.

Explanation

Correct Answer

C:

Low toner supply often causes light or patchy laser print output. Black text prints at normal density after consumable replacement.

Incorrect Answers

A:

Printer language mismatches can produce garbled page data. Replace the approved toner cartridge and run print-density tests.

B:

Intermittent connector contact can interrupt video signaling. Low toner supply often causes light or patchy laser print output.

D:

Co-channel interference and congestion cause intermittent wireless performance. Replace the approved toner cartridge and run print-density tests.