mcAfee Secure Website
23

CompTIA 220-1101 Bundle

Exam Code: 220-1101

Exam Name CompTIA A+ Certification Exam: Core 1

Certification Provider: CompTIA

Corresponding Certification: CompTIA A+

220-1101 Training Materials $44.99

Reliable & Actual Study Materials for 220-1101 Exam Success

The Latest 220-1101 Exam Questions as Experienced in the Actual Test!

  • 24
    Questions & Answers

    220-1101 Questions & Answers

    519 Questions & Answers

    Includes questions types found on actual exam such as drag and drop, simulation, type in, and fill in the blank.

  • 25
    220-1101 Video Course

    220-1101 Training Course

    201 Video Lectures

    Based on Real Life Scenarios which you will encounter in exam and learn by working with real equipment.

  • exam =30
    Study Guide

    220-1101 Study Guide

    3030 PDF Pages

    Study Guide developed by industry experts who have written exams in the past. They are technology-specific IT certification researchers with at least a decade of experience at Fortune 500 companies.

exam =32

CompTIA A+ Certification Exam: Core 1 (220-1101) Practice Tests

Guarantee

Satisfaction Guaranteed

Pass4sure has a remarkable CompTIA Candidate Success record. We're confident of our products and provide no hassle product exchange. That's how confident we are!

99.3% Pass Rate
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • exam =34
    Questions & Answers

    Questions & Answers

    519 Questions

    $124.99
    exam =35
  • exam =37
    220-1101 Video Course

    Training Course

    201 Video Lectures

    $39.99
  • exam =36
    Study Guide

    Study Guide

    3030 PDF Pages

    $29.99

CompTIA 220-1101 Practice Test 40

Question 390

At Cedar laboratory, a preventive-maintenance review describes the following separate device or service incident: A rack server is connected to an optical uplink with LC duplex interfaces and no copper data link is available. Which technical explanation most directly supports the recommended response?

  1. USB connector adaptation can preserve compatible data signaling when host mode is supported.
  2. Fiber connections require matching optical transceivers, connector types and media.
  3. Removable media can suffer corruption and should be verified during transfer.
  4. Network printer reachability and access policy matter beyond driver installation.

Explanation

Correct Answer

B:

Select compatible fiber patch cable and optics with the correct LC connector and fiber standard. The optical interface achieves link and reports healthy optical power readings.

Incorrect Answers

A:

Choose a supported USB-C-to-USB-A adapter that preserves the needed USB data connection. The optical interface achieves link and reports healthy optical power readings.

C:

Read and hash representative files, scan per policy and retain an independent destination copy. Fiber connections require matching optical transceivers, connector types and media.

D:

Configure an authorized network-print path with suitable VLAN/ACL and wireless print compatibility. The optical interface achieves link and reports healthy optical power readings.

Question 391

At Beacon campus, a service request describes the following separate device or service incident: A tablet charges only when its cable is held at an angle, even with known-good chargers. Which outcome or shortcut would most clearly show that the technician has NOT addressed the problem safely?

  1. Changing the screen brightness cannot repair dead touch zones.
  2. Changing the DHCP lease cannot restore a worn projector lamp.
  3. Disabling Bluetooth will not repair a bent charge-port contact.
  4. Declaring success based on one quick ping may miss recurring congestion.

Explanation

Correct Answer

C:

A damaged charging connector may cause intermittent power contact. Inspect the charging port and cable for physical damage and perform approved port repair.

Incorrect Answers

A:

Display output and touch input are distinct functional layers. Inspect the charging port and cable for physical damage and perform approved port repair.

B:

Projection lamps can degrade with operating hours. A damaged charging connector may cause intermittent power contact.

D:

Successful repair should be validated against the original impact scope. Inspect the charging port and cable for physical damage and perform approved port repair.

Question 392

A workstation's date and time reset whenever it is fully disconnected from AC power. Which outcome or shortcut would most clearly show that the technician has NOT addressed the problem safely?

  1. Turning off thermal safeguards instead of restoring cooling is unsafe.
  2. Resetting every router before checking the recently disturbed cable can enlarge an outage.
  3. Replacing the video card does not supply standby RTC power.
  4. Pressing the swollen battery flat or continuing to charge can trigger thermal failure.

Explanation

Correct Answer

C:

The RTC battery maintains certain firmware settings without external power. Check and replace the CMOS/RTC coin-cell battery according to hardware guidance.

Incorrect Answers

A:

Overtemperature protection may turn off a system to prevent damage. The RTC battery maintains certain firmware settings without external power.

B:

Troubleshooting begins by gathering evidence and narrowing likely causes. Firmware clock settings persist across a full unplugged period.

D:

A swollen lithium battery is a safety hazard and should not be punctured or stressed. The RTC battery maintains certain firmware settings without external power.

Question 393

A laser printer leaves toner unfused so the image rubs off the sheet immediately after printing. Which observation would best confirm that the original issue was resolved?

  1. A continuous test batch feeds without folds and toner properly fuses.
  2. Temperature stays within specification during a controlled load test.
  3. Test pages retain the toner image after normal handling.
  4. Inspection verifies the jacket rating and the link passes category cable tests.

Explanation

Correct Answer

C:

A laser printer's fuser uses heat and pressure to bond toner to paper. Inspect and replace the fuser assembly following safety and service procedures.

Incorrect Answers

A:

Misaligned heated-path components can damage paper and degrade print quality. Test pages retain the toner image after normal handling.

B:

Thermal contact and heat transfer are required for CPU stability. Inspect and replace the fuser assembly following safety and service procedures.

D:

Cable-jacket fire ratings matter in designated air-handling spaces. Test pages retain the toner image after normal handling.

Question 394

A monitor has DisplayPort input while the workstation supplies only a compatible HDMI output. Which technical explanation most directly supports the recommended response?

  1. USB connector adaptation can preserve compatible data signaling when host mode is supported.
  2. Memory controllers use board-specific population rules.
  3. M.2 describes form factor while SATA and NVMe/PCIe describe different interfaces.
  4. Video adapter direction and signal conversion requirements must be verified.

Explanation

Correct Answer

D:

Select a properly rated HDMI-to-DisplayPort conversion solution with correct directionality and power requirements. The monitor displays the intended resolution at a stable refresh rate.

Incorrect Answers

A:

Choose a supported USB-C-to-USB-A adapter that preserves the needed USB data connection. Select a properly rated HDMI-to-DisplayPort conversion solution with correct directionality and power requirements.

B:

Populate the first recommended slot rather than choosing an arbitrary socket. Video adapter direction and signal conversion requirements must be verified.

C:

Confirm the motherboard's M.2 keying and protocol support before selecting a SATA-compatible drive. The monitor displays the intended resolution at a stable refresh rate.

Question 395

A RAID 5 array reports a failed member but still serves files in degraded mode. Which outcome or shortcut would most clearly show that the technician has NOT addressed the problem safely?

  1. Pulling an unrelated healthy drive from a degraded RAID 5 can cause data loss.
  2. Forcing an undersized disk into a rebuild can fail or jeopardize array availability.
  3. Repeated power cycling of visibly damaged hardware risks fire or further damage.
  4. Resetting every router before checking the recently disturbed cable can enlarge an outage.

Explanation

Correct Answer

A:

RAID 5 can tolerate one drive failure, but degraded mode raises risk until rebuilt. Identify the failed member precisely and replace it with a compatible disk under the vendor rebuild procedure.

Incorrect Answers

B:

Redundant arrays may reject member disks smaller than the required geometry. The array finishes rebuilding and returns to healthy redundancy with data checks.

C:

Visible electrical damage is a stop-work safety condition, not a software issue. Identify the failed member precisely and replace it with a compatible disk under the vendor rebuild procedure.

D:

Troubleshooting begins by gathering evidence and narrowing likely causes. RAID 5 can tolerate one drive failure, but degraded mode raises risk until rebuilt.

Question 396

A service technician restores a workstation after a hardware replacement but has not verified its user workload. Which outcome or shortcut would most clearly show that the technician has NOT addressed the problem safely?

  1. Ordering the original suspected part despite contrary tests wastes time.
  2. Repeatedly plugging in a wet phone can cause further damage.
  3. Closing the incident solely because the power LED lights leaves the fault unverified.
  4. A correct DNS record alone cannot route packets when the gateway is wrong.

Explanation

Correct Answer

C:

Verification and documentation are part of a complete troubleshooting cycle. Run representative functional tests, check recurrence and document preventive actions.

Incorrect Answers

A:

Failed hypotheses should be revised rather than treated as confirmed root causes. The user's normal applications run without the original symptom and the ticket contains the outcome.

B:

Liquid intrusion can cause conductive corrosion and short circuits. Run representative functional tests, check recurrence and document preventive actions.

D:

Default gateways handle traffic to destinations outside the local network. The user's normal applications run without the original symptom and the ticket contains the outcome.

Question 397

A desktop shows a previously healthy data disk as missing immediately after an internal power supply swap. Which outcome or shortcut would most clearly show that the technician has NOT addressed the problem safely?

  1. Forcing unprotected write-back mode increases corruption risk during power loss.
  2. Adding toner to a direct thermal printer cannot clear the heating element.
  3. Initializing the undetected drive is unsafe and can destroy metadata if it reappears.
  4. Replacing the projector bulb is unlikely to fix a wrong source selection.

Explanation

Correct Answer

C:

Loss of drive power can look like missing media at the operating-system level. Verify compatible SATA power and data cabling before attempting file-system repair.

Incorrect Answers

A:

Protected write-back cache may be restricted when backup power is unavailable. Verify compatible SATA power and data cabling before attempting file-system repair.

B:

Thermal printhead contamination disrupts local heat transfer to the paper. Loss of drive power can look like missing media at the operating-system level.

D:

Input selection must match the physically connected signal. Verify compatible SATA power and data cabling before attempting file-system repair.

Question 398

A workstation randomly freezes after a memory upgrade using modules with conflicting speed profiles. Which response would most directly address this requirement while respecting the described facts?

  1. Return to validated memory timings and test the modules individually under supported settings.
  2. Safely clean the cooling path and verify fan operation and thermal contact.
  3. Investigate the imaging drum or fusing path using vendor-specific interval checks.
  4. Service the approved cache-protection component and verify policy after replacement.

Explanation

Correct Answer

A:

Unstable memory timings may cause intermittent application failures. Repeated memory tests run without errors at supported settings.

Incorrect Answers

B:

Overtemperature protection may turn off a system to prevent damage. Repeated memory tests run without errors at supported settings.

C:

Repeating image defects can trace to rotating imaging or fusing components. Return to validated memory timings and test the modules individually under supported settings.

D:

Protected write-back cache may be restricted when backup power is unavailable. Unstable memory timings may cause intermittent application failures.

Question 399

A remote home-office user can reach local printers but internet browsing times out after the router WAN cable was unplugged. Which observation would best confirm that the original issue was resolved?

  1. The link LED and Ethernet negotiation recover with the replacement cable.
  2. The device is deemed electrically safe before any restoration or power test.
  3. Brightness returns within accepted levels after supported service.
  4. The router establishes ISP connectivity and clients can browse an external test site.

Explanation

Correct Answer

D:

Local LAN communication can continue even when the internet uplink fails. Restore the approved WAN connection and verify router external address and routing.

Incorrect Answers

A:

Physical cable damage can disrupt Ethernet signaling before IP configuration. The router establishes ISP connectivity and clients can browse an external test site.

B:

Liquid intrusion can cause conductive corrosion and short circuits. Restore the approved WAN connection and verify router external address and routing.

C:

Projection lamps can degrade with operating hours. Local LAN communication can continue even when the internet uplink fails.

Question 400

A tablet's touch cursor drifts despite a clean screen and no physical damage. Which response would most directly address this requirement while respecting the described facts?

  1. Test external notification and panel connections, then assess the display assembly.
  2. Run the approved touch calibration and test for persistent digitizer errors.
  3. Verify compatible SATA power and data cabling before attempting file-system repair.
  4. Inspect application and driver output settings before replacing mechanical parts.

Explanation

Correct Answer

B:

Touch-input drift may be caused by calibration or digitizer faults. A multi-point test shows touch alignment within tolerance.

Incorrect Answers

A:

A phone can remain operational when only its display assembly is damaged. Run the approved touch calibration and test for persistent digitizer errors.

C:

Loss of drive power can look like missing media at the operating-system level. A multi-point test shows touch alignment within tolerance.

D:

Driver/application transformations can alter print layout without engine failure. Run the approved touch calibration and test for persistent digitizer errors.