mcAfee Secure Website
23

CompTIA 220-1101 Bundle

Exam Code: 220-1101

Exam Name CompTIA A+ Certification Exam: Core 1

Certification Provider: CompTIA

Corresponding Certification: CompTIA A+

220-1101 Training Materials $44.99

Reliable & Actual Study Materials for 220-1101 Exam Success

The Latest 220-1101 Exam Questions as Experienced in the Actual Test!

  • 24
    Questions & Answers

    220-1101 Questions & Answers

    519 Questions & Answers

    Includes questions types found on actual exam such as drag and drop, simulation, type in, and fill in the blank.

  • 25
    220-1101 Video Course

    220-1101 Training Course

    201 Video Lectures

    Based on Real Life Scenarios which you will encounter in exam and learn by working with real equipment.

  • exam =30
    Study Guide

    220-1101 Study Guide

    3030 PDF Pages

    Study Guide developed by industry experts who have written exams in the past. They are technology-specific IT certification researchers with at least a decade of experience at Fortune 500 companies.

exam =32

CompTIA A+ Certification Exam: Core 1 (220-1101) Practice Tests

Guarantee

Satisfaction Guaranteed

Pass4sure has a remarkable CompTIA Candidate Success record. We're confident of our products and provide no hassle product exchange. That's how confident we are!

99.3% Pass Rate
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • exam =34
    Questions & Answers

    Questions & Answers

    519 Questions

    $124.99
    exam =35
  • exam =37
    220-1101 Video Course

    Training Course

    201 Video Lectures

    $39.99
  • exam =36
    Study Guide

    Study Guide

    3030 PDF Pages

    $29.99

CompTIA 220-1101 Practice Test 18

Question 170

A notebook can connect to Wi-Fi near the access point but becomes unusable at normal office distance after a screen repair. Which outcome or shortcut would most clearly show that the technician has NOT addressed the problem safely?

  1. Upgrading the operating system will not reconnect a pinched or detached antenna lead.
  2. Resetting Bluetooth pairings does not reverse uneven OLED subpixel wear.
  3. Substituting a passive touchscreen glove cannot provide unsupported pressure sensing.
  4. Removing the original drive before backup validation can lose irreplaceable content.

Explanation

Correct Answer

A:

Many laptop wireless antennas are located in the display assembly. Check antenna cable routing and connectors through the display hinge according to the service guide.

Incorrect Answers

B:

OLED emitters can age unevenly under prolonged static content. Signal strength at the original desk returns to its prior level after reconnection.

C:

A stylus is not universally supported just because a display accepts finger touch. Check antenna cable routing and connectors through the display hinge according to the service guide.

D:

Data preservation and boot configuration are key parts of disk migration. Many laptop wireless antennas are located in the display assembly.

Question 171

An organization requires firmware-based boot-chain trust on supported PCs. Which response would most directly address this requirement while respecting the described facts?

  1. Enable supported UEFI Secure Boot with appropriately signed boot components and confirm policy compatibility.
  2. Reseat the compatible cooler, ensure proper thermal interface and fan operation.
  3. Choose a supported PSU or approved adapter within electrical and compatibility ratings.
  4. Inspect and replace the fuser assembly following safety and service procedures.

Explanation

Correct Answer

A:

Secure Boot verifies boot component signatures when configured correctly. The machine boots approved signed loaders and rejects a prohibited unsigned test loader.

Incorrect Answers

B:

Thermal contact and heat transfer are required for CPU stability. Enable supported UEFI Secure Boot with appropriately signed boot components and confirm policy compatibility.

C:

Motherboard power-connector pinout and rail capacity must be compatible. Secure Boot verifies boot component signatures when configured correctly.

D:

A laser printer's fuser uses heat and pressure to bond toner to paper. The machine boots approved signed loaders and rejects a prohibited unsigned test loader.

Question 172

A workstation's date and time reset whenever it is fully disconnected from AC power. Which observation would best confirm that the original issue was resolved?

  1. A specific failing component is identified and the system completes POST after repair.
  2. The agreed change completes with stakeholder notice and a verified rollback path.
  3. Firmware clock settings persist across a full unplugged period.
  4. The client holds stable association and acceptable throughput at the affected desk.

Explanation

Correct Answer

C:

The RTC battery maintains certain firmware settings without external power. Check and replace the CMOS/RTC coin-cell battery according to hardware guidance.

Incorrect Answers

A:

Fan motion alone does not prove CPU, RAM and firmware initialized correctly. Check and replace the CMOS/RTC coin-cell battery according to hardware guidance.

B:

Corporate procedures and business impact must be considered before implementing repairs. The RTC battery maintains certain firmware settings without external power.

D:

Co-channel interference and congestion cause intermittent wireless performance. Check and replace the CMOS/RTC coin-cell battery according to hardware guidance.

Question 173

A server develops intermittent corrected memory errors in firmware event logs. Which response would most directly address this requirement while respecting the described facts?

  1. Order the correct laptop SODIMM type and verify generation and capacity support.
  2. Enable printer authentication or secure-release printing where supported.
  3. Run approved memory diagnostics, identify the affected supported DIMM and replace it in a maintenance window.
  4. Replace the boot drive with a supported SSD and migrate the operating environment safely.

Explanation

Correct Answer

C:

ECC event counters can identify memory modules developing correctable faults. Error counters stop increasing and the new DIMM passes testing.

Incorrect Answers

A:

SODIMMs have a smaller form factor than desktop DIMMs. ECC event counters can identify memory modules developing correctable faults.

B:

Secure print queues control when sensitive pages physically appear. Error counters stop increasing and the new DIMM passes testing.

D:

Solid-state storage avoids mechanical seek latency for common random I/O. ECC event counters can identify memory modules developing correctable faults.

Question 174

Several computers on one floor lose connectivity while a core router remains healthy; one access switch is dark. Which observation would best confirm that the original issue was resolved?

  1. The client can ping the correct gateway and reach permitted remote subnets.
  2. Restoring switch service returns link and connectivity to the floor's clients.
  3. A diagnosed bottleneck is corrected and repeat latency measurements improve.
  4. Black text prints at normal density after consumable replacement.

Explanation

Correct Answer

B:

A single access switch failure can affect many downstream hosts. Check the failed switch's power and uplink before diagnosing individual PCs.

Incorrect Answers

A:

Default gateways handle traffic to destinations outside the local network. Restoring switch service returns link and connectivity to the floor's clients.

C:

Storage slowness may reflect failing media, link saturation or controller conditions. A single access switch failure can affect many downstream hosts.

D:

Low toner supply often causes light or patchy laser print output. Restoring switch service returns link and connectivity to the floor's clients.

Question 175

A monitor has DisplayPort input while the workstation supplies only a compatible HDMI output. Which outcome or shortcut would most clearly show that the technician has NOT addressed the problem safely?

  1. An RJ45 Ethernet patch lead cannot mate directly to an F-type coax port.
  2. Replacing the monitor cannot reduce disk seek time.
  3. Assuming every passive adapter converts HDMI output to DisplayPort input can leave a blank screen.
  4. Squeezing a full-size DIMM into a SODIMM slot is not a valid installation.

Explanation

Correct Answer

C:

Video adapter direction and signal conversion requirements must be verified. Select a properly rated HDMI-to-DisplayPort conversion solution with correct directionality and power requirements.

Incorrect Answers

A:

F-type connectors commonly terminate coaxial broadband cable. Select a properly rated HDMI-to-DisplayPort conversion solution with correct directionality and power requirements.

B:

Solid-state storage avoids mechanical seek latency for common random I/O. Video adapter direction and signal conversion requirements must be verified.

D:

SODIMMs have a smaller form factor than desktop DIMMs. Select a properly rated HDMI-to-DisplayPort conversion solution with correct directionality and power requirements.

Question 176

A computer loses power when peripherals are connected, and the PSU's 5 V rail sags below specification. Which outcome or shortcut would most clearly show that the technician has NOT addressed the problem safely?

  1. Using an underpowered generic adapter can leave the same electrical limitation.
  2. Ignoring a low-voltage rail and reinstalling graphics drivers will not correct the electrical fault.
  3. Choosing a different font does not make the scanner handle multiple pages automatically.
  4. Installing both modules arbitrarily cannot guarantee dual-channel operation.

Explanation

Correct Answer

B:

A PSU rail can fail under load despite a no-load power-good indication. Test the power supply against the platform's load requirements and replace a failing unit.

Incorrect Answers

A:

Power supply selection must consider peak draw, efficiency and connector compatibility. A PSU rail can fail under load despite a no-load power-good indication.

C:

An ADF supports document batch scanning; a flatbed is better for fragile items. Test the power supply against the platform's load requirements and replace a failing unit.

D:

Memory channel layout depends on the motherboard's documented slot population. A PSU rail can fail under load despite a no-load power-good indication.

Question 177

A home router is installed with a /24 LAN and users require local connectivity plus internet access. Which outcome or shortcut would most clearly show that the technician has NOT addressed the problem safely?

  1. Entering a 169.254 IPv4 address does not enable IPv6 routing.
  2. Reconfiguring a healthy DHCP scope will not start a stopped web server.
  3. Setting the gateway to an unrelated subnet address prevents off-LAN routing.
  4. Twisting wires together without crimping provides no standards-compliant RJ45 termination.

Explanation

Correct Answer

C:

Subnet mask and gateway determine local versus routed traffic. Configure LAN subnet, DHCP pool, default gateway and WAN uplink coherently.

Incorrect Answers

A:

IPv6 address configuration differs from IPv4 and does not rely on APIPA. Clients reach the local gateway, resolve DNS and access permitted internet resources.

B:

DNS may work even when the actual web-hosting service fails. Configure LAN subnet, DHCP pool, default gateway and WAN uplink coherently.

D:

Correct tools and pin assignments produce reliable copper terminations. Clients reach the local gateway, resolve DNS and access permitted internet resources.

Question 178

At Beacon campus, a service request describes the following separate device or service incident: A tablet charges only when its cable is held at an angle, even with known-good chargers. Which response would most directly address this requirement while respecting the described facts?

  1. Stop powering it, follow liquid-damage triage and refer for safe board-level assessment.
  2. Protect data promptly using an approved backup or recovery process and replace the failing drive.
  3. Collect change history, test the disturbed physical link and form a hypothesis before broad network resets.
  4. Inspect the charging port and cable for physical damage and perform approved port repair.

Explanation

Correct Answer

D:

A damaged charging connector may cause intermittent power contact. Charging remains stable with a normal undisturbed cable connection.

Incorrect Answers

A:

Liquid intrusion can cause conductive corrosion and short circuits. Inspect the charging port and cable for physical damage and perform approved port repair.

B:

Mechanical clicks with SMART degradation indicate possible impending storage failure. A damaged charging connector may cause intermittent power contact.

C:

Troubleshooting begins by gathering evidence and narrowing likely causes. Charging remains stable with a normal undisturbed cable connection.

Question 179

At Delta field office, an IT support visit describes the following separate device or service incident: A workstation shuts down after several minutes of heavy load and the CPU heat sink is clogged with dust. Which response would most directly address this requirement while respecting the described facts?

  1. Test the external power path and PSU output before replacing the motherboard.
  2. Inspect the charging port and cable for physical damage and perform approved port repair.
  3. Restore the approved WAN connection and verify router external address and routing.
  4. Safely clean the cooling path and verify fan operation and thermal contact.

Explanation

Correct Answer

D:

Overtemperature protection may turn off a system to prevent damage. CPU temperature remains in spec under sustained workload without forced shutdown.

Incorrect Answers

A:

No-power faults can originate before the motherboard receives usable power. Overtemperature protection may turn off a system to prevent damage.

B:

A damaged charging connector may cause intermittent power contact. CPU temperature remains in spec under sustained workload without forced shutdown.

C:

Local LAN communication can continue even when the internet uplink fails. Safely clean the cooling path and verify fan operation and thermal contact.

Question 180

A desktop has no network link light after its cable was caught under a chair. Which technical explanation most directly supports the recommended response?

  1. Co-channel interference and congestion cause intermittent wireless performance.
  2. Physical cable damage can disrupt Ethernet signaling before IP configuration.
  3. Unstable memory timings may cause intermittent application failures.
  4. Mechanical clicks with SMART degradation indicate possible impending storage failure.

Explanation

Correct Answer

B:

Test the patch cord and port with a known-good cable and physical link check. The link LED and Ethernet negotiation recover with the replacement cable.

Incorrect Answers

A:

Survey nearby access points and choose a supported less-congested channel or band. The link LED and Ethernet negotiation recover with the replacement cable.

C:

Return to validated memory timings and test the modules individually under supported settings. Physical cable damage can disrupt Ethernet signaling before IP configuration.

D:

Protect data promptly using an approved backup or recovery process and replace the failing drive. The link LED and Ethernet negotiation recover with the replacement cable.