Cisco 350-601 Bundle

Exam Code: 350-601

Exam Name Implementing and Operating Cisco Data Center Core Technologies (DCCOR)

Certification Provider: Cisco

Corresponding Certifications: CCIE Data Center , CCNP Data Center

350-601 Training Materials $25.00

Reliable & Actual Study Materials for 350-601 Exam Success

The Latest 350-601 Exam Questions as Experienced in the Actual Test!

  • 24
    Questions & Answers

    350-601 Questions & Answers

    630 Questions & Answers

    Includes questions types found on actual exam such as drag and drop, simulation, type in, and fill in the blank.

  • 25
    350-601 Video Course

    350-601 Training Course

    143 Video Lectures

    Based on Real Life Scenarios which you will encounter in exam and learn by working with real equipment.

exam =32

Implementing and Operating Cisco Data Center Core Technologies (DCCOR) (350-601) Practice Tests

Guarantee

Satisfaction Guaranteed

Pass4sure has a remarkable Cisco Candidate Success record. We're confident of our products and provide no hassle product exchange. That's how confident we are!

99.3% Pass Rate
Total Cost: $164.98
Bundle Price: $139.98

Purchase Individually

  • exam =34
    Questions & Answers

    Questions & Answers

    630 Questions

    $124.99
    exam =35
  • exam =37
    350-601 Video Course

    Training Course

    143 Video Lectures

    $39.99

Cisco 350-601 Practice Test 7

Question 60

While checking a production data center change, the team finds: An automation client retries an administrative NX-API request repeatedly after receiving HTTP 403, misclassifying authorization denial as a transient device failure. Which deployment safeguard most directly reduces this failure risk?

  1. Document shell boundaries and supported packages before on-box automation deployment.
  2. Test rerun behavior and configuration diffs before scheduling on-box Python automation.
  3. Audit scheduler job frequency and execution history after automation changes.
  4. Build explicit error classification and bounded retries into every infrastructure API client.

Explanation

Correct Answer

D:

This safeguard addresses rest api authorization status handling: The REST client does not distinguish insufficient authorization from retryable transport or server errors. The appropriate prevention is: Build explicit error classification and bounded retries into every infrastructure API client. Other subsystem controls would not address the specified recurring failure.

Incorrect Answers

A:

The deployment confuses NX-OS Bash Shell execution with the separately managed Guest Shell environment. “Document shell boundaries and supported packages before on-box automation deployment” would address that alternative cause, not the condition in this question: the REST client does not distinguish insufficient authorization from retryable transport or server errors.

B:

“Test rerun behavior and configuration diffs before scheduling on-box Python automation” responds to this separate finding: the script lacks an idempotent precheck to compare desired and current network device state. This question instead needs “Build explicit error classification and bounded retries into every infrastructure API client”, so the alternative does not meet the stated condition.

C:

The NX-OS scheduler job timing is not aligned with the intended maintenance frequency. “Audit scheduler job frequency and execution history after automation changes” applies to that separate problem. The observed case is an automation client retries an administrative NX-API request repeatedly after receiving HTTP 403, misclassifying authorization denial as a transient device failure; choosing this alternative would address the wrong failure mode.

Question 61

During a Cisco data center readiness review, engineers observe: An NFS mount command fails from a new virtualization host even though the storage array responds to ping, and the export permits only the retired host subnet. Which approved technology action addresses this incident most directly?

  1. Update the approved initiator and target CHAP secret settings using the supported secure workflow.
  2. Update the scoped NFS export policy to include only the approved new hypervisor client addresses.
  3. Select and provision the required supported iSCSI block LUN rather than treating an NFS export as a raw disk.
  4. Activate the approved zoneset containing the authorized initiator-target zone and verify effective zoning.

Explanation

Correct Answer

B:

The root problem is that The NFS export access rules do not authorize the requesting client address or security identity. The selected change addresses it directly: Update the scoped NFS export policy to include only the approved new hypervisor client addresses. Verify the outcome: The new host mounts the intended export while an unauthorized client remains denied.

Incorrect Answers

A:

This action concerns iscsi chap target authentication, where The iSCSI initiator and storage target do not agree on the configured CHAP authentication credentials. The reported failure instead stems from The NFS export access rules do not authorize the requesting client address or security identity.

C:

This action concerns nfs file storage versus iscsi block storage, where The application storage requirements conflate NFS file-sharing semantics with iSCSI block-device presentation. The corrective response here is “Update the scoped NFS export policy to include only the approved new hypervisor client addresses”; this alternative does not provide that response.

D:

This action concerns active fibre channel zoneset validation, where An inactive zoning database edit does not change the effective active zoneset on the SAN fabric. The stem reports an NFS mount command fails from a new virtualization host even though the storage array responds to ping, and the export permits only the retired host subnet; this control addresses a different failure condition.

Question 62

While checking a production data center change, the team finds: An HBA completes fabric login but the intended target WWPN cannot be discovered because the target never registers with the Fibre Channel name server. What is the primary technical reason the deployment fails?

  1. An inactive zoning database edit does not change the effective active zoneset on the SAN fabric.
  2. The zone combines initiators beyond the least-privilege single-initiator zoning design.
  3. The target's FCNS registration is absent or stale even though the initiator's local FLOGI succeeded.
  4. Device alias changes have not been committed and distributed through the supported fabric database workflow.

Explanation

Correct Answer

C:

The technical cause is The target's FCNS registration is absent or stale even though the initiator's local FLOGI succeeded. The appropriate response is: Verify target port FLOGI and FCNS registration and restore the authorized target attachment. Confirm successful repair: The MDS name-server database contains the correct target and initiator identities for the relevant VSAN.

Incorrect Answers

A:

An inactive zoning database edit does not change the effective active zoneset on the SAN fabric. “Activate the approved zoneset containing the authorized initiator-target zone and verify effective zoning” would address that alternative cause, not the condition in this question: the target's FCNS registration is absent or stale even though the initiator's local FLOGI succeeded.

B:

“Create separate approved zones for each host initiator with its authorized storage target ports” responds to this separate finding: the zone combines initiators beyond the least-privilege single-initiator zoning design. This question instead needs “Verify target port FLOGI and FCNS registration and restore the authorized target attachment”, so the alternative does not meet the stated condition.

D:

Device alias changes have not been committed and distributed through the supported fabric database workflow. “Commit the approved device alias database transaction and verify resolution across the affected switches” applies to that separate problem. The observed case is an HBA completes fabric login but the intended target WWPN cannot be discovered because the target never registers with the Fibre Channel name server; choosing this alternative would address the wrong failure mode.

Question 63

During a Cisco data center readiness review, engineers observe: A newly installed blade chassis has power but its I/O modules and blades never appear under fabric-interconnect inventory after uplink cabling was changed. What is the primary technical reason the deployment fails?

  1. The clustered fabric-interconnect pair is not configured or tested for the expected management failover behavior.
  2. The configured boot-device order does not select the intended SAN boot path before local storage.
  3. The CIMC management interface has incorrect IP addressing or missing management default gateway reachability.
  4. The chassis discovery path between the fabric interconnect and its I/O modules is absent or misconfigured.

Explanation

Correct Answer

D:

The technical cause is The chassis discovery path between the fabric interconnect and its I/O modules is absent or misconfigured. The appropriate response is: Correct the supported fabric-interconnect server-port and chassis connectivity assignments, then rediscover the chassis. Confirm successful repair: Both intended fabric paths enumerate the chassis and associated blades under UCS management.

Incorrect Answers

A:

The clustered fabric-interconnect pair is not configured or tested for the expected management failover behavior. “Repair the UCS fabric-interconnect cluster and management redundancy configuration and validate supported failover” would address that alternative cause, not the condition in this question: the chassis discovery path between the fabric interconnect and its I/O modules is absent or misconfigured.

B:

“Restore the supported boot policy and required SAN adapter path in the correct boot-device order” responds to this separate finding: the configured boot-device order does not select the intended SAN boot path before local storage. This question instead needs “Correct the supported fabric-interconnect server-port and chassis connectivity assignments, then rediscover the chassis”, so the alternative does not meet the stated condition.

C:

The CIMC management interface has incorrect IP addressing or missing management default gateway reachability. “Configure the approved CIMC out-of-band address, gateway and management VLAN from a secured administration network” applies to that separate problem. The observed case is a newly installed blade chassis has power but its I/O modules and blades never appear under fabric-interconnect inventory after uplink cabling was changed; choosing this alternative would address the wrong failure mode.

Question 64

A Nexus, UCS or MDS operations team encounters this issue: An Intersight-managed UCS X blade receives a server profile but fails its deployment because mandatory network and storage policy references are missing. Which test outcome proves the intended service was restored?

  1. The blade retains expected connectivity under an individual fabric path outage within the approved design.
  2. The profile deploys without unresolved policy references and the server boots with intended connections.
  3. The chassis and compute nodes are managed through the expected Intersight policy and profile model.
  4. The server appears as a manageable authorized target in the correct Intersight organization.

Explanation

Correct Answer

B:

This observation validates intersight server profile deployment consistency: The Intersight server profile lacks a complete set of supported adapter, boot and connectivity policies. The corresponding corrective action is: Complete the required Intersight policies and deploy the server profile with validated resource assignments. Evidence about a different component does not establish the requested service outcome.

Incorrect Answers

A:

The chassis fabric attachment and server adapter mapping have not been configured for both intended IOM paths. “Restore the supported redundant IOM-to-fabric-interconnect attachments and verify adapter pinning behavior” would address that alternative cause, not the condition in this question: the Intersight server profile lacks a complete set of supported adapter, boot and connectivity policies.

C:

“Use the supported UCS X-Series Intersight Managed Mode workflow and associate appropriate server profile policies” responds to this separate finding: the platform deployment assumes a management mode inconsistent with the intended UCS X-Series architecture. This question instead needs “Complete the required Intersight policies and deploy the server profile with validated resource assignments”, so the alternative does not meet the stated condition.

D:

The Intersight device claim and account authorization do not match the approved administrative organization. “Reconcile the claim code and target ownership through supported Intersight claiming and access procedures” applies to that separate problem. The observed case is an Intersight-managed UCS X blade receives a server profile but fails its deployment because mandatory network and storage policy references are missing; choosing this alternative would address the wrong failure mode.

Question 65

During a Cisco data center readiness review, engineers observe: A data center team modifies a static service profile on every blade individually, causing configuration drift when a shared SAN policy changes. Which approved technology action addresses this incident most directly?

  1. Create the supported UCS server pool qualification and associate the workload profile with eligible members.
  2. Permit the intended VLAN on the correct UCS fabric uplink and downstream network policies without broad wildcard access.
  3. Use an approved updating service profile template and apply governed changes to its associated server profiles.
  4. Correct the supported UCS class-of-service and network QoS policy for the intended application traffic.

Explanation

Correct Answer

C:

The root problem is that The configuration process bypasses the intended reusable UCS service profile template inheritance model. The selected change addresses it directly: Use an approved updating service profile template and apply governed changes to its associated server profiles. Verify the outcome: All attached eligible blades receive consistent policy changes with documented exceptions and maintenance impact.

Incorrect Answers

A:

This action concerns ucs server pool qualification matching, where The server pool qualification policy does not limit placement to servers with the required hardware capabilities. The reported failure instead stems from The configuration process bypasses the intended reusable UCS service profile template inheritance model.

B:

This action concerns ucs vlan uplink permitted configuration, where The VLAN is absent from the approved UCS LAN uplink connectivity or external switch trunk policy. The corrective response here is “Use an approved updating service profile template and apply governed changes to its associated server profiles”; this alternative does not provide that response.

D:

This action concerns ucs lan qos class mapping, where UCS system QoS class and vNIC network-control treatment are not aligned to the traffic priority requirements. The stem reports a data center team modifies a static service profile on every blade individually, causing configuration drift when a shared SAN policy changes; this control addresses a different failure condition.

Question 66

A Nexus, UCS or MDS operations team encounters this issue: A new Cisco UCS C-Series rack server boots its operating system, yet the remote administrators cannot access CIMC because the out-of-band address is on an unreachable subnet. Which verification result most directly demonstrates successful repair?

  1. A controlled reboot starts the server from the authorized SAN boot target and reaches the expected OS.
  2. Both intended fabric paths enumerate the chassis and associated blades under UCS management.
  3. The secondary fabric interconnect takes over management duties without losing the approved domain configuration.
  4. Authorized operators can open CIMC over the management path without exposing it on the application data plane.

Explanation

Correct Answer

D:

This observation validates ucs c series cimc management networking: The CIMC management interface has incorrect IP addressing or missing management default gateway reachability. The corresponding corrective action is: Configure the approved CIMC out-of-band address, gateway and management VLAN from a secured administration network. Evidence about a different component does not establish the requested service outcome.

Incorrect Answers

A:

The configured boot-device order does not select the intended SAN boot path before local storage. “Restore the supported boot policy and required SAN adapter path in the correct boot-device order” would address that alternative cause, not the condition in this question: the CIMC management interface has incorrect IP addressing or missing management default gateway reachability.

B:

“Correct the supported fabric-interconnect server-port and chassis connectivity assignments, then rediscover the chassis” responds to this separate finding: the chassis discovery path between the fabric interconnect and its I/O modules is absent or misconfigured. This question instead needs “Configure the approved CIMC out-of-band address, gateway and management VLAN from a secured administration network”, so the alternative does not meet the stated condition.

C:

The clustered fabric-interconnect pair is not configured or tested for the expected management failover behavior. “Repair the UCS fabric-interconnect cluster and management redundancy configuration and validate supported failover” applies to that separate problem. The observed case is a new Cisco UCS C-Series rack server boots its operating system, yet the remote administrators cannot access CIMC because the out-of-band address is on an unreachable subnet; choosing this alternative would address the wrong failure mode.

Question 67

A data center implementation team investigates the following fault: A Cisco Nexus switch locally observes abnormal traffic, but the monitoring platform receives no NetFlow records after the exporter destination was moved. Which corrective change best resolves this problem?

  1. Repair the approved flow exporter source, destination and transport route, and verify collector acceptance.
  2. Review supported orphan-port handling and move or protect the workload on the planned resilient attachment.
  3. Configure the authorized SPAN source and monitor-only destination and confirm the capture appliance connection.
  4. Enable approved supported streaming telemetry and Nexus Dashboard assurance views for relevant fabric health metrics.

Explanation

Correct Answer

A:

The root problem is that Flow-export destination reachability or the configured source and monitoring VRF are incorrect. The selected change addresses it directly: Repair the approved flow exporter source, destination and transport route, and verify collector acceptance. Verify the outcome: The collector receives valid sampled flow records with the expected device identity and timestamps.

Incorrect Answers

B:

This action concerns vpc orphan port convergence, where The failure design does not account for orphan-port behavior and the chosen peer recovery semantics. The reported failure instead stems from Flow-export destination reachability or the configured source and monitoring VRF are incorrect.

C:

This action concerns span source and destination isolation, where The SPAN session source and dedicated monitor destination roles were assigned incorrectly. The corrective response here is “Repair the approved flow exporter source, destination and transport route, and verify collector acceptance”; this alternative does not provide that response.

D:

This action concerns nexus dashboard assurance and streaming telemetry, where The monitoring design lacks continuous streaming telemetry and historical assurance correlation for transient events. The stem reports a Cisco Nexus switch locally observes abnormal traffic, but the monitoring platform receives no NetFlow records after the exporter destination was moved; this control addresses a different failure condition.

Question 68

While checking a production data center change, the team finds: A newly introduced access VLAN sees ARP spoofing attempts despite DHCP snooping being enabled because no dynamic ARP inspection policy is active for the VLAN. What observation best confirms the configuration now behaves correctly?

  1. Hosts ignore the unauthorized router advertisement and retain the approved IPv6 default gateway.
  2. The user can inspect authorized SAN settings but cannot change unrelated server identity and LAN policies.
  3. Spoofed ARP replies are discarded while authorized clients retain normal gateway connectivity.
  4. Unauthorized DHCP offers are dropped while valid clients receive leases from the approved server.

Explanation

Correct Answer

C:

This observation validates dynamic arp inspection binding validation: DHCP-snooping address bindings are not being enforced by dynamic ARP inspection on the affected VLAN. The corresponding corrective action is: Enable supported dynamic ARP inspection and validate binding data and trusted uplink settings. Evidence about a different component does not establish the requested service outcome.

Incorrect Answers

A:

The access ports lack the supported first-hop security policy needed to restrict untrusted IPv6 router advertisements. “Apply the approved IPv6 RA guard behavior to untrusted host-facing ports while permitting designated router ports” would address that alternative cause, not the condition in this question: dHCP-snooping address bindings are not being enforced by dynamic ARP inspection on the affected VLAN.

B:

“Assign a supported restricted UCS role and scope matching the storage administration tasks” responds to this separate finding: the UCS administrative role assignment grants privileges beyond the user's defined operational responsibilities. This question instead needs “Enable supported dynamic ARP inspection and validate binding data and trusted uplink settings”, so the alternative does not meet the stated condition.

D:

DHCP snooping trust is applied to an untrusted edge port and allows unauthorized DHCP server replies. “Remove DHCP-snooping trust from the host access port and retain trust only on authorized server-facing paths” applies to that separate problem. The observed case is a newly introduced access VLAN sees ARP spoofing attempts despite DHCP snooping being enabled because no dynamic ARP inspection policy is active for the VLAN; choosing this alternative would address the wrong failure mode.

Question 69

During a Cisco data center readiness review, engineers observe: A virtual machine migrates to a different ESXi host but its ACI EPG policy does not follow because the virtualization integration is incomplete. What observation best confirms the configuration now behaves correctly?

  1. After VM migration the endpoint belongs to the right EPG and retains its intended connectivity and contracts.
  2. APIC reports the expected interface and EPG deployment, and authorized server traffic is forwarded.
  3. Unicast learning and authorized broadcast discovery work without traffic being replicated to unrelated VTEPs.
  4. APIC shows the assigned leaf as an active fabric member with the expected spine adjacency.

Explanation

Correct Answer

A:

This observation validates aci vmm domain dynamic endpoint learning: The ACI VMM domain connection does not synchronize the intended endpoint group to its virtual switch port groups. The corresponding corrective action is: Repair the approved ACI VMM integration and EPG domain association, then validate policy deployment. Evidence about a different component does not establish the requested service outcome.

Incorrect Answers

B:

The interface selector and policy-group to physical-domain binding do not deliver the intended EPG attachment. “Correct the supported ACI interface policy selector and physical domain association for the host-facing port” would address that alternative cause, not the condition in this question: the ACI VMM domain connection does not synchronize the intended endpoint group to its virtual switch port groups.

C:

“Inspect the bridge-domain BUM replication method and configure only approved VTEP replication membership” responds to this separate finding: bUM replication handling does not reflect the intended VNI flood list and supported replication or multicast model. This question instead needs “Repair the approved ACI VMM integration and EPG domain association, then validate policy deployment”, so the alternative does not meet the stated condition.

D:

The leaf has not completed the supported ACI fabric discovery and node-registration workflow. “Verify fabric ports, discovery connectivity and the intended node identity, then register the new leaf in APIC” applies to that separate problem. The observed case is a virtual machine migrates to a different ESXi host but its ACI EPG policy does not follow because the virtualization integration is incomplete; choosing this alternative would address the wrong failure mode.

Question 70

A data center administrator identifies the following risk: A monitoring Python script assumes a nested JSON metric is always a number and crashes when NX-OS telemetry omits the optional field on one hardware platform. Which root cause best explains this behavior?

  1. The playbook target inventory and variable precedence do not isolate the intended lab device group.
  2. The parser lacks schema validation and robust handling of absent or differently typed telemetry values.
  3. The POAP discovery data identifies the wrong approved bootstrap artifact for the device's placement.
  4. The RDMA transport has not been mapped to an appropriate lossless traffic class with congestion safeguards.

Explanation

Correct Answer

B:

The technical cause is The parser lacks schema validation and robust handling of absent or differently typed telemetry values. The appropriate response is: Validate expected JSON fields and handle missing data explicitly before calculating fabric health metrics. Confirm successful repair: The collector processes supported payload variants and flags incomplete metrics without terminating the monitoring job.

Incorrect Answers

A:

The playbook target inventory and variable precedence do not isolate the intended lab device group. “Constrain the approved Ansible inventory and host patterns, then review the playbook diff before execution” would address that alternative cause, not the condition in this question: the parser lacks schema validation and robust handling of absent or differently typed telemetry values.

C:

“Correct the controlled DHCP provisioning information and match the bootstrap script to the switch identity” responds to this separate finding: the POAP discovery data identifies the wrong approved bootstrap artifact for the device's placement. This question instead needs “Validate expected JSON fields and handle missing data explicitly before calculating fabric health metrics”, so the alternative does not meet the stated condition.

D:

The RDMA transport has not been mapped to an appropriate lossless traffic class with congestion safeguards. “Evaluate supported PFC and ECN settings for the RDMA class and validate them across the intended switch path” applies to that separate problem. The observed case is a monitoring Python script assumes a nested JSON metric is always a number and crashes when NX-OS telemetry omits the optional field on one hardware platform; choosing this alternative would address the wrong failure mode.