Implementing and Operating Cisco Data Center Core Technologies (DCCOR) (350-601) Practice Tests

Guarantee

Satisfaction Guaranteed

Pass4sure has a remarkable Cisco Candidate Success record. We're confident of our products and provide no hassle product exchange. That's how confident we are!

99.3% Pass Rate
Total Cost: $164.98
Bundle Price: $139.98

Purchase Individually

  • exam =34
    Questions & Answers

    Questions & Answers

    630 Questions

    $124.99
    exam =35
  • exam =37
    350-601 Video Course

    Training Course

    143 Video Lectures

    $39.99

Cisco 350-601 Practice Test 37

Question 360

While checking a production data center change, the team finds: A Windows automation job uses PowerShell to invoke Intersight APIs but embeds a long-lived administrative secret in a shared source script. What is the primary technical reason the deployment fails?

  1. The infrastructure-as-code state and actual network infrastructure have drifted without pre-apply reconciliation.
  2. The API workflow fails to resolve the correct scoped Intersight policy identifier before server profile association.
  3. The deployment confuses NX-OS Bash Shell execution with the separately managed Guest Shell environment.
  4. The automation credential is stored insecurely and grants broader privileges than the script requires.

Explanation

Correct Answer

D:

The technical cause is The automation credential is stored insecurely and grants broader privileges than the script requires. The appropriate response is: Move credentials to a supported secret store and use a scoped authorized API identity for PowerShell requests. Confirm successful repair: The job retrieves the required device data without exposing secrets in the repository or task logs.

Incorrect Answers

A:

The infrastructure-as-code state and actual network infrastructure have drifted without pre-apply reconciliation. “Refresh and inspect the Terraform plan, reconcile authorized drift and then apply only approved resources” would address that alternative cause, not the condition in this question: the automation credential is stored insecurely and grants broader privileges than the script requires.

B:

“Use stable approved resource IDs and validate organization scope before assigning Intersight policies” responds to this separate finding: the API workflow fails to resolve the correct scoped Intersight policy identifier before server profile association. This question instead needs “Move credentials to a supported secret store and use a scoped authorized API identity for PowerShell requests”, so the alternative does not meet the stated condition.

C:

The deployment confuses NX-OS Bash Shell execution with the separately managed Guest Shell environment. “Deploy the script in the approved supported shell environment with required dependencies and bounded permissions” applies to that separate problem. The observed case is a Windows automation job uses PowerShell to invoke Intersight APIs but embeds a long-lived administrative secret in a shared source script; choosing this alternative would address the wrong failure mode.

Question 361

A newly commissioned network, compute or storage service reports: An engineer changes a Nexus port-channel policy and several interfaces stop passing traffic, but no approved prechange rollback point exists. What is the primary technical reason the deployment fails?

  1. Flow-export destination reachability or the configured source and monitoring VRF are incorrect.
  2. The change process omitted a recoverable NX-OS configuration checkpoint and validation plan.
  3. The planned software transition omits the EPLD compatibility and operational impact assessment.
  4. The upgrade plan assumes ISSU support without validating the platform release path and active feature constraints.

Explanation

Correct Answer

B:

The technical cause is The change process omitted a recoverable NX-OS configuration checkpoint and validation plan. The appropriate response is: Create and use a supported configuration checkpoint or approved rollback before editing the production policy. Confirm successful repair: The device returns to the known-good configuration with traffic restored after rollback is exercised.

Incorrect Answers

A:

Flow-export destination reachability or the configured source and monitoring VRF are incorrect. “Repair the approved flow exporter source, destination and transport route, and verify collector acceptance” would address that alternative cause, not the condition in this question: the change process omitted a recoverable NX-OS configuration checkpoint and validation plan.

C:

“Review supported EPLD package requirements and schedule the component update using the prescribed procedure” responds to this separate finding: the planned software transition omits the EPLD compatibility and operational impact assessment. This question instead needs “Create and use a supported configuration checkpoint or approved rollback before editing the production policy”, so the alternative does not meet the stated condition.

D:

The upgrade plan assumes ISSU support without validating the platform release path and active feature constraints. “Check the published release and ISSU compatibility matrix and select a supported maintenance or disruptive path” applies to that separate problem. The observed case is an engineer changes a Nexus port-channel policy and several interfaces stop passing traffic, but no approved prechange rollback point exists; choosing this alternative would address the wrong failure mode.

Question 362

While checking a production data center change, the team finds: An infrastructure automation identity can edit server policies in several unrelated Intersight organizations even though it supports just one business unit. What observation best confirms the configuration now behaves correctly?

  1. The user can inspect authorized SAN settings but cannot change unrelated server identity and LAN policies.
  2. Unauthorized DHCP offers are dropped while valid clients receive leases from the approved server.
  3. The identity updates permitted server profiles in its organization and receives denials elsewhere.
  4. Authorized operators authenticate normally through remote AAA and recover access through the documented fallback during an outage.

Explanation

Correct Answer

C:

This observation validates intersight organization scoped administrative role: The Intersight role assignment is not scoped to the authorized organization and permitted resource actions. The corresponding corrective action is: Apply the approved organization-scoped Intersight RBAC role for the automation identity. Evidence about a different component does not establish the requested service outcome.

Incorrect Answers

A:

The UCS administrative role assignment grants privileges beyond the user's defined operational responsibilities. “Assign a supported restricted UCS role and scope matching the storage administration tasks” would address that alternative cause, not the condition in this question: the Intersight role assignment is not scoped to the authorized organization and permitted resource actions.

B:

“Remove DHCP-snooping trust from the host access port and retain trust only on authorized server-facing paths” responds to this separate finding: dHCP snooping trust is applied to an untrusted edge port and allows unauthorized DHCP server replies. This question instead needs “Apply the approved organization-scoped Intersight RBAC role for the automation identity”, so the alternative does not meet the stated condition.

D:

The UCS login realm and remote AAA fallback policy do not provide the documented secured recovery path. “Correct the supported UCS authentication realm order and emergency access procedure under change control” applies to that separate problem. The observed case is an infrastructure automation identity can edit server policies in several unrelated Intersight organizations even though it supports just one business unit; choosing this alternative would address the wrong failure mode.

Question 363

A data center implementation team investigates the following fault: A new WWPN zone has been created in the MDS zoning database but the application host still cannot see its storage array because the zoneset was never activated. Which test outcome proves the intended service was restored?

  1. The new host mounts the intended export while an unauthorized client remains denied.
  2. The active zoneset includes the desired members and the server discovers only its allowed storage target.
  3. Each host discovers its intended target while unrelated initiator WWPNs are not jointly zoned.
  4. The fabric accepts a new authorized zoning transaction with consistent configuration distribution.

Explanation

Correct Answer

B:

This observation validates active fibre channel zoneset validation: An inactive zoning database edit does not change the effective active zoneset on the SAN fabric. The corresponding corrective action is: Activate the approved zoneset containing the authorized initiator-target zone and verify effective zoning. Evidence about a different component does not establish the requested service outcome.

Incorrect Answers

A:

The NFS export access rules do not authorize the requesting client address or security identity. “Update the scoped NFS export policy to include only the approved new hypervisor client addresses” would address that alternative cause, not the condition in this question: an inactive zoning database edit does not change the effective active zoneset on the SAN fabric.

C:

“Create separate approved zones for each host initiator with its authorized storage target ports” responds to this separate finding: the zone combines initiators beyond the least-privilege single-initiator zoning design. This question instead needs “Activate the approved zoneset containing the authorized initiator-target zone and verify effective zoning”, so the alternative does not meet the stated condition.

D:

A Cisco Fabric Services zoning transaction lock is still held by an unfinished or failed session. “Identify the legitimate lock owner and safely complete or abort the supported CFS session” applies to that separate problem. The observed case is a new WWPN zone has been created in the MDS zoning database but the application host still cannot see its storage array because the zoneset was never activated; choosing this alternative would address the wrong failure mode.

Question 364

A data center implementation team investigates the following fault: A new UCS server is physically reachable but cannot be managed from the organization's Intersight account because its device claim was associated with a different account. What preventive control would best avoid repeating this fault?

  1. Validate failover semantics against the host operating system teaming configuration before production use.
  2. Review Intersight target claims and account lifecycle as part of server ownership transfers.
  3. Schedule encrypted UCS configuration backups and perform periodic isolated restore tests.
  4. Verify the supported UCS generation and management mode before migrating service policies.

Explanation

Correct Answer

B:

This safeguard addresses cisco intersight target claim ownership: The Intersight device claim and account authorization do not match the approved administrative organization. The appropriate prevention is: Review Intersight target claims and account lifecycle as part of server ownership transfers. Other subsystem controls would not address the specified recurring failure.

Incorrect Answers

A:

The UCS vNIC fabric placement and failover policy do not provide the intended redundant network path. “Validate failover semantics against the host operating system teaming configuration before production use” would address that alternative cause, not the condition in this question: the Intersight device claim and account authorization do not match the approved administrative organization.

C:

“Schedule encrypted UCS configuration backups and perform periodic isolated restore tests” responds to this separate finding: the UCS domain disaster-recovery process lacks a tested full configuration backup and restoration workflow. This question instead needs “Review Intersight target claims and account lifecycle as part of server ownership transfers”, so the alternative does not meet the stated condition.

D:

The platform deployment assumes a management mode inconsistent with the intended UCS X-Series architecture. “Verify the supported UCS generation and management mode before migrating service policies” applies to that separate problem. The observed case is a new UCS server is physically reachable but cannot be managed from the organization's Intersight account because its device claim was associated with a different account; choosing this alternative would address the wrong failure mode.

Question 365

A data center administrator identifies the following risk: A new VXLAN segment experiences unnecessary broadcast amplification when unknown unicast and multicast frames are flooded broadly without validating overlay replication. Which corrective change best resolves this problem?

  1. Review supported orphan-port handling and move or protect the workload on the planned resilient attachment.
  2. Inspect the bridge-domain BUM replication method and configure only approved VTEP replication membership.
  3. Verify fabric ports, discovery connectivity and the intended node identity, then register the new leaf in APIC.
  4. Correct the supported ACI interface policy selector and physical domain association for the host-facing port.

Explanation

Correct Answer

B:

The root problem is that BUM replication handling does not reflect the intended VNI flood list and supported replication or multicast model. The selected change addresses it directly: Inspect the bridge-domain BUM replication method and configure only approved VTEP replication membership. Verify the outcome: Unicast learning and authorized broadcast discovery work without traffic being replicated to unrelated VTEPs.

Incorrect Answers

A:

This action concerns vpc orphan port convergence, where The failure design does not account for orphan-port behavior and the chosen peer recovery semantics. The reported failure instead stems from BUM replication handling does not reflect the intended VNI flood list and supported replication or multicast model.

C:

This action concerns aci leaf onboarding discovery, where The leaf has not completed the supported ACI fabric discovery and node-registration workflow. The corrective response here is “Inspect the bridge-domain BUM replication method and configure only approved VTEP replication membership”; this alternative does not provide that response.

D:

This action concerns aci access policy interface selector binding, where The interface selector and policy-group to physical-domain binding do not deliver the intended EPG attachment. The stem reports a new VXLAN segment experiences unnecessary broadcast amplification when unknown unicast and multicast frames are flooded broadly without validating overlay replication; this control addresses a different failure condition.

Question 366

A newly commissioned network, compute or storage service reports: An Ansible playbook meant for lab Nexus switches changes production switch banners because its inventory group variables include production hosts inadvertently. Which deployment safeguard most directly reduces this failure risk?

  1. Treat centrally managed fabric intent as authoritative and audit out-of-band changes.
  2. Review inventory membership and variable precedence before every network automation deployment.
  3. Use representative multi-platform telemetry fixtures in automated parser regression tests.
  4. Audit scheduler job frequency and execution history after automation changes.

Explanation

Correct Answer

B:

This safeguard addresses ansible inventory variable scoping: The playbook target inventory and variable precedence do not isolate the intended lab device group. The appropriate prevention is: Review inventory membership and variable precedence before every network automation deployment. Other subsystem controls would not address the specified recurring failure.

Incorrect Answers

A:

Device-level modifications are not reconciled with the authoritative Nexus Dashboard fabric policy model. “Treat centrally managed fabric intent as authoritative and audit out-of-band changes” would address that alternative cause, not the condition in this question: the playbook target inventory and variable precedence do not isolate the intended lab device group.

C:

“Use representative multi-platform telemetry fixtures in automated parser regression tests” responds to this separate finding: the parser lacks schema validation and robust handling of absent or differently typed telemetry values. This question instead needs “Review inventory membership and variable precedence before every network automation deployment”, so the alternative does not meet the stated condition.

D:

The NX-OS scheduler job timing is not aligned with the intended maintenance frequency. “Audit scheduler job frequency and execution history after automation changes” applies to that separate problem. The observed case is an Ansible playbook meant for lab Nexus switches changes production switch banners because its inventory group variables include production hosts inadvertently; choosing this alternative would address the wrong failure mode.

Question 367

During a Cisco data center readiness review, engineers observe: A monitoring Python script assumes a nested JSON metric is always a number and crashes when NX-OS telemetry omits the optional field on one hardware platform. Which deployment safeguard most directly reduces this failure risk?

  1. Review inventory membership and variable precedence before every network automation deployment.
  2. Use representative multi-platform telemetry fixtures in automated parser regression tests.
  3. Measure AI job communication patterns and model network growth before adding GPU clusters.
  4. Test PFC deadlock risk and congestion behavior before production AI network scale-out.

Explanation

Correct Answer

B:

This safeguard addresses python structured telemetry parsing: The parser lacks schema validation and robust handling of absent or differently typed telemetry values. The appropriate prevention is: Use representative multi-platform telemetry fixtures in automated parser regression tests. Other subsystem controls would not address the specified recurring failure.

Incorrect Answers

A:

The playbook target inventory and variable precedence do not isolate the intended lab device group. “Review inventory membership and variable precedence before every network automation deployment” would address that alternative cause, not the condition in this question: the parser lacks schema validation and robust handling of absent or differently typed telemetry values.

C:

“Measure AI job communication patterns and model network growth before adding GPU clusters” responds to this separate finding: the data center fabric bandwidth and latency design do not match the high-throughput GPU collective workload. This question instead needs “Use representative multi-platform telemetry fixtures in automated parser regression tests”, so the alternative does not meet the stated condition.

D:

The RDMA transport has not been mapped to an appropriate lossless traffic class with congestion safeguards. “Test PFC deadlock risk and congestion behavior before production AI network scale-out” applies to that separate problem. The observed case is a monitoring Python script assumes a nested JSON metric is always a number and crashes when NX-OS telemetry omits the optional field on one hardware platform; choosing this alternative would address the wrong failure mode.

Question 368

A data center administrator identifies the following risk: An IPv6-only data center link has working layer-three connectivity but an OSPFv3 neighbor never forms because opposite ends use different area assignments. What is the most appropriate remediation for these symptoms?

  1. Configure matching OSPFv3 area assignments and verify the intended IPv6 interface participation.
  2. Repair the approved ACI VMM integration and EPG domain association, then validate policy deployment.
  3. Align the approved interface MTU settings on both ends and then reestablish the OSPF adjacency.
  4. Restore the approved rendezvous-point mapping and multicast routing reachability for the affected groups.

Explanation

Correct Answer

A:

The root problem is that The OSPFv3 processes attach the shared IPv6 link to incompatible OSPF area contexts. The selected change addresses it directly: Configure matching OSPFv3 area assignments and verify the intended IPv6 interface participation. Verify the outcome: The two routers establish an OSPFv3 Full adjacency and learn the expected IPv6 prefixes.

Incorrect Answers

B:

This action concerns aci vmm domain dynamic endpoint learning, where The ACI VMM domain connection does not synchronize the intended endpoint group to its virtual switch port groups. The reported failure instead stems from The OSPFv3 processes attach the shared IPv6 link to incompatible OSPF area contexts.

C:

This action concerns ospfv2 adjacency mtu mismatch, where The neighboring OSPF interfaces disagree on MTU and database description negotiation cannot complete reliably. The corrective response here is “Configure matching OSPFv3 area assignments and verify the intended IPv6 interface participation”; this alternative does not provide that response.

D:

This action concerns pim multicast rendezvous point reachability, where The routers do not agree on or reach the required rendezvous-point mapping for the multicast group range. The stem reports an IPv6-only data center link has working layer-three connectivity but an OSPFv3 neighbor never forms because opposite ends use different area assignments; this control addresses a different failure condition.

Question 369

While checking a production data center change, the team finds: An NFS mount command fails from a new virtualization host even though the storage array responds to ping, and the export permits only the retired host subnet. Which operational guardrail would prevent a similar outage?

  1. Reconcile NFS export client authorization when hypervisor subnets or hosts change.
  2. Validate iSCSI authentication lifecycle and secret rotation with connectivity testing.
  3. Use capture scope and SAN data sensitivity review before activating port mirroring.
  4. Document file versus block protocols as separate design decisions in storage onboarding.

Explanation

Correct Answer

A:

This safeguard addresses nfs export client authorization: The NFS export access rules do not authorize the requesting client address or security identity. The appropriate prevention is: Reconcile NFS export client authorization when hypervisor subnets or hosts change. Other subsystem controls would not address the specified recurring failure.

Incorrect Answers

B:

The iSCSI initiator and storage target do not agree on the configured CHAP authentication credentials. “Validate iSCSI authentication lifecycle and secret rotation with connectivity testing” would address that alternative cause, not the condition in this question: the NFS export access rules do not authorize the requesting client address or security identity.

C:

“Use capture scope and SAN data sensitivity review before activating port mirroring” responds to this separate finding: the Fibre Channel SPAN session source does not identify the failing interface or service path. This question instead needs “Reconcile NFS export client authorization when hypervisor subnets or hosts change”, so the alternative does not meet the stated condition.

D:

The application storage requirements conflate NFS file-sharing semantics with iSCSI block-device presentation. “Document file versus block protocols as separate design decisions in storage onboarding” applies to that separate problem. The observed case is an NFS mount command fails from a new virtualization host even though the storage array responds to ping, and the export permits only the retired host subnet; choosing this alternative would address the wrong failure mode.

Question 370

A data center administrator identifies the following risk: A blade replacement is delayed because the team assumes MAC addresses and server identities must remain bound to the failed physical blade. What preventive control would best avoid repeating this fault?

  1. Audit WWPN pool ranges and identity assignment for uniqueness before UCS service profile deployment.
  2. Maintain service profile templates and identity pools independent of individual server serial numbers.
  3. Validate failover semantics against the host operating system teaming configuration before production use.
  4. Check UCS vHBA VSAN mapping and the upstream storage fabric when provisioning SAN boot.

Explanation

Correct Answer

B:

This safeguard addresses ucs service profile server identity: The server identity has not been abstracted through approved UCS service profile and identity-pool associations. The appropriate prevention is: Maintain service profile templates and identity pools independent of individual server serial numbers. Other subsystem controls would not address the specified recurring failure.

Incorrect Answers

A:

The vHBA WWPN allocation violates uniqueness requirements across server storage initiators. “Audit WWPN pool ranges and identity assignment for uniqueness before UCS service profile deployment” would address that alternative cause, not the condition in this question: the server identity has not been abstracted through approved UCS service profile and identity-pool associations.

C:

“Validate failover semantics against the host operating system teaming configuration before production use” responds to this separate finding: the UCS vNIC fabric placement and failover policy do not provide the intended redundant network path. This question instead needs “Maintain service profile templates and identity pools independent of individual server serial numbers”, so the alternative does not meet the stated condition.

D:

The virtual HBA path is not participating in the intended Fibre Channel VSAN end to end. “Check UCS vHBA VSAN mapping and the upstream storage fabric when provisioning SAN boot” applies to that separate problem. The observed case is a blade replacement is delayed because the team assumes MAC addresses and server identities must remain bound to the failed physical blade; choosing this alternative would address the wrong failure mode.