Question 310
While checking a production data center change, the team finds: Two VXLAN leaf switches serve the same tenant bridge domain but forward frames to different VXLAN network identifiers due to mismatched local mappings. Which approved technology action addresses this incident most directly?
Explanation
Correct Answer
The root problem is that The tenant VLAN-to-VNI mappings do not identify the same approved layer-two segment across VTEPs. The selected change addresses it directly: Align the intended VLAN-to-VNI bindings and associated NVE membership on the participating leaves. Verify the outcome: Hosts in the authorized segment communicate across leaves while unrelated tenant segments remain separate.
Incorrect Answers
This action concerns nexus epld upgrade safety, where The planned software transition omits the EPLD compatibility and operational impact assessment. The reported failure instead stems from The tenant VLAN-to-VNI mappings do not identify the same approved layer-two segment across VTEPs.
This action concerns vxlan vtep loopback reachability, where The NVE source loopback and remote VTEP reachability are not present in the required underlay routing domain. The corrective response here is “Align the intended VLAN-to-VNI bindings and associated NVE membership on the participating leaves”; this alternative does not provide that response.
This action concerns evpn ip prefix type five advertisement, where The routed tenant VRF prefix is not being exported or imported as an appropriate EVPN IP-prefix route. The stem reports two VXLAN leaf switches serve the same tenant bridge domain but forward frames to different VXLAN network identifiers due to mismatched local mappings; this control addresses a different failure condition.