mcAfee Secure Website
23

Cisco 350-601 Bundle

Exam Code: 350-601

Exam Name Implementing and Operating Cisco Data Center Core Technologies (DCCOR)

Certification Provider: Cisco

Corresponding Certifications: CCIE Data Center , CCNP Data Center

350-601 Training Materials $25.00

Reliable & Actual Study Materials for 350-601 Exam Success

The Latest 350-601 Exam Questions as Experienced in the Actual Test!

  • 24
    Questions & Answers

    350-601 Questions & Answers

    630 Questions & Answers

    Includes questions types found on actual exam such as drag and drop, simulation, type in, and fill in the blank.

  • 25
    350-601 Video Course

    350-601 Training Course

    143 Video Lectures

    Based on Real Life Scenarios which you will encounter in exam and learn by working with real equipment.

exam =32

Implementing and Operating Cisco Data Center Core Technologies (DCCOR) (350-601) Practice Tests

Guarantee

Satisfaction Guaranteed

Pass4sure has a remarkable Cisco Candidate Success record. We're confident of our products and provide no hassle product exchange. That's how confident we are!

99.3% Pass Rate
Total Cost: $164.98
Bundle Price: $139.98

Purchase Individually

  • exam =34
    Questions & Answers

    Questions & Answers

    630 Questions

    $124.99
    exam =35
  • exam =37
    350-601 Video Course

    Training Course

    143 Video Lectures

    $39.99

Cisco 350-601 Practice Test 25

Question 240

A data center administrator identifies the following risk: An installed UCS blade becomes unreachable when the only mapped I/O module path is disabled although a second IOM is physically available. Which verification result most directly demonstrates successful repair?

  1. The replacement blade identifies the intended LUN and completes a controlled SAN boot.
  2. The guest and external hosts exchange traffic over the authorized VLAN on both supported fabric paths.
  3. The blade retains expected connectivity under an individual fabric path outage within the approved design.
  4. Authorized real-time flows receive the designated priority treatment and bulk traffic retains its separate class.

Explanation

Correct Answer

C:

This observation validates ucs chassis iom fabric path redundancy: The chassis fabric attachment and server adapter mapping have not been configured for both intended IOM paths. The corresponding corrective action is: Restore the supported redundant IOM-to-fabric-interconnect attachments and verify adapter pinning behavior. Evidence about a different component does not establish the requested service outcome.

Incorrect Answers

A:

The SAN boot policy refers to an unavailable storage target identity rather than the authorized active target. “Update the service profile boot policy to use the valid target WWPN and correct boot LUN parameters” would address that alternative cause, not the condition in this question: the chassis fabric attachment and server adapter mapping have not been configured for both intended IOM paths.

B:

“Permit the intended VLAN on the correct UCS fabric uplink and downstream network policies without broad wildcard access” responds to this separate finding: the VLAN is absent from the approved UCS LAN uplink connectivity or external switch trunk policy. This question instead needs “Restore the supported redundant IOM-to-fabric-interconnect attachments and verify adapter pinning behavior”, so the alternative does not meet the stated condition.

D:

UCS system QoS class and vNIC network-control treatment are not aligned to the traffic priority requirements. “Correct the supported UCS class-of-service and network QoS policy for the intended application traffic” applies to that separate problem. The observed case is an installed UCS blade becomes unreachable when the only mapped I/O module path is disabled although a second IOM is physically available; choosing this alternative would address the wrong failure mode.

Question 241

While checking a production data center change, the team finds: A UCS rack server remains pingable but begins memory error correction bursts, while monitoring checks only network availability and misses hardware faults. Which operational guardrail would prevent a similar outage?

  1. Test UCS QoS policies with the upstream switching trust boundary after adapter-policy changes.
  2. Review association change previews, reboot implications and backout steps before production reassignment.
  3. Include hardware sensors and fault trend alerts in the standard UCS server health baseline.
  4. Tie UCS BIOS templates to documented operating system and hypervisor compatibility requirements.

Explanation

Correct Answer

C:

This safeguard addresses intersight hardware telemetry alarm review: The monitoring coverage does not include relevant server hardware health telemetry and Intersight fault history. The appropriate prevention is: Include hardware sensors and fault trend alerts in the standard UCS server health baseline. Other subsystem controls would not address the specified recurring failure.

Incorrect Answers

A:

UCS system QoS class and vNIC network-control treatment are not aligned to the traffic priority requirements. “Test UCS QoS policies with the upstream switching trust boundary after adapter-policy changes” would address that alternative cause, not the condition in this question: the monitoring coverage does not include relevant server hardware health telemetry and Intersight fault history.

B:

“Review association change previews, reboot implications and backout steps before production reassignment” responds to this separate finding: the service profile reassociation workflow ignores its potential disruptive impact on server identities and boot settings. This question instead needs “Include hardware sensors and fault trend alerts in the standard UCS server health baseline”, so the alternative does not meet the stated condition.

D:

The BIOS policy disables required CPU virtualization support expected by the approved hypervisor. “Tie UCS BIOS templates to documented operating system and hypervisor compatibility requirements” applies to that separate problem. The observed case is a UCS rack server remains pingable but begins memory error correction bursts, while monitoring checks only network availability and misses hardware faults; choosing this alternative would address the wrong failure mode.

Question 242

During a Cisco data center readiness review, engineers observe: A new stateless UCS blade service profile has its boot policy set to a retired target WWPN, so the host never discovers the correct boot LUN. Which approved technology action addresses this incident most directly?

  1. Expand or assign a nonoverlapping approved MAC pool and retry the service profile association.
  2. Replace conflicting values with separate approved WWPN pool allocations and verify SAN fabric registration.
  3. Assign the supported vHBA and fabric-facing SAN connectivity to the approved target VSAN.
  4. Update the service profile boot policy to use the valid target WWPN and correct boot LUN parameters.

Explanation

Correct Answer

D:

The root problem is that The SAN boot policy refers to an unavailable storage target identity rather than the authorized active target. The selected change addresses it directly: Update the service profile boot policy to use the valid target WWPN and correct boot LUN parameters. Verify the outcome: The replacement blade identifies the intended LUN and completes a controlled SAN boot.

Incorrect Answers

A:

This action concerns ucs mac address pool exhaustion, where The UCS MAC identity pool has insufficient available addresses for the requested vNIC identities. The reported failure instead stems from The SAN boot policy refers to an unavailable storage target identity rather than the authorized active target.

B:

This action concerns ucs wwpn pool uniqueness, where The vHBA WWPN allocation violates uniqueness requirements across server storage initiators. The corrective response here is “Update the service profile boot policy to use the valid target WWPN and correct boot LUN parameters”; this alternative does not provide that response.

C:

This action concerns ucs vhba vsan assignment consistency, where The virtual HBA path is not participating in the intended Fibre Channel VSAN end to end. The stem reports a new stateless UCS blade service profile has its boot policy set to a retired target WWPN, so the host never discovers the correct boot LUN; this control addresses a different failure condition.

Question 243

During a Cisco data center readiness review, engineers observe: Intermittent Fibre Channel congestion causes storage latency spikes, yet operators rely only on link-up indicators and miss buffer-credit or port-error trends. Which implementation action should the engineer take first?

  1. Enable supported MDS telemetry and Nexus Dashboard fabric views for congestion and error analysis.
  2. Correct the supported F-port settings and investigate FLOGI exchange for the intended initiator.
  3. Review the applicable MDS EPLD package and schedule the correct supported component update.
  4. Set a supported FC SPAN monitor source for the affected port and the approved capture destination.

Explanation

Correct Answer

A:

The root problem is that The SAN observability baseline does not collect relevant port performance metrics and historical assurance trends. The selected change addresses it directly: Enable supported MDS telemetry and Nexus Dashboard fabric views for congestion and error analysis. Verify the outcome: A time-aligned report identifies the affected SAN ports and correlates counters with storage latency.

Incorrect Answers

B:

This action concerns flogi registration and fcid assignment, where The initiator has not completed successful fabric login and thus has no authorized FCID assignment. The reported failure instead stems from The SAN observability baseline does not collect relevant port performance metrics and historical assurance trends.

C:

This action concerns cisco mds epld hardware dependency, where The storage switch plan omits an EPLD package compatibility assessment for the target hardware and image. The corrective response here is “Enable supported MDS telemetry and Nexus Dashboard fabric views for congestion and error analysis”; this alternative does not provide that response.

D:

This action concerns cisco mds span fibre channel troubleshooting, where The Fibre Channel SPAN session source does not identify the failing interface or service path. The stem reports intermittent Fibre Channel congestion causes storage latency spikes, yet operators rely only on link-up indicators and miss buffer-credit or port-error trends; this control addresses a different failure condition.

Question 244

A data center administrator identifies the following risk: Multicast video receivers remain connected at layer two, but group membership ages out because there is no active IGMP querier in their VLAN. Which test outcome proves the intended service was restored?

  1. After VM migration the endpoint belongs to the right EPG and retains its intended connectivity and contracts.
  2. The collector receives valid sampled flow records with the expected device identity and timestamps.
  3. The design describes the private deployment and any genuinely shared public components without conflating connectivity.
  4. Interested ports retain multicast group membership and nonmembers do not receive unwanted replicated streams.

Explanation

Correct Answer

D:

This observation validates igmp snooping querier requirement: IGMP snooping membership state is not refreshed because the VLAN lacks a reachable supported multicast querier. The corresponding corrective action is: Provide a valid IGMP querier through the routed gateway or supported switching configuration. Evidence about a different component does not establish the requested service outcome.

Incorrect Answers

A:

The ACI VMM domain connection does not synchronize the intended endpoint group to its virtual switch port groups. “Repair the approved ACI VMM integration and EPG domain association, then validate policy deployment” would address that alternative cause, not the condition in this question: the VLAN lacks a reachable supported multicast querier.

B:

“Repair the approved flow exporter source, destination and transport route, and verify collector acceptance” responds to this separate finding: flow-export destination reachability or the configured source and monitoring VRF are incorrect. This question instead needs “Provide a valid IGMP querier through the routed gateway or supported switching configuration”, so the alternative does not meet the stated condition.

C:

Cloud deployment models are determined by ownership and audience characteristics, not simply by Internet accessibility. “Classify the environment using NIST deployment-model definitions and document any hybrid integration boundaries” applies to that separate problem. The observed case is multicast video receivers remain connected at layer two, but group membership ages out because there is no active IGMP querier in their VLAN; choosing this alternative would address the wrong failure mode.

Question 245

A data center administrator identifies the following risk: Two distribution switches provide HSRP default gateways, but the active switch continues answering for the virtual gateway after losing its only upstream path. Which corrective change best resolves this problem?

  1. Classify the environment using NIST deployment-model definitions and document any hybrid integration boundaries.
  2. Configure matching OSPFv3 area assignments and verify the intended IPv6 interface participation.
  3. Configure supported HSRP tracking and priority decrement so the healthy upstream switch takes the active role.
  4. Activate the correct EVPN address family for authorized peers and verify route advertisement policy.

Explanation

Correct Answer

C:

The root problem is that The first-hop redundancy design lacks effective upstream object tracking and priority adjustment for the failed link. The selected change addresses it directly: Configure supported HSRP tracking and priority decrement so the healthy upstream switch takes the active role. Verify the outcome: After an uplink failure, the standby switch becomes active and application traffic uses its available upstream path.

Incorrect Answers

A:

This action concerns nist public private hybrid cloud models, where Cloud deployment models are determined by ownership and audience characteristics, not simply by Internet accessibility. The reported failure instead stems from The first-hop redundancy design lacks effective upstream object tracking and priority adjustment for the failed link.

B:

This action concerns ospfv3 ipv6 area consistency, where The OSPFv3 processes attach the shared IPv6 link to incompatible OSPF area contexts. The corrective response here is “Configure supported HSRP tracking and priority decrement so the healthy upstream switch takes the active role”; this alternative does not provide that response.

D:

This action concerns mp-BGP evpn address family activation, where The BGP peers lack the required L2VPN EVPN address-family activation and exchange capability. The stem reports two distribution switches provide HSRP default gateways, but the active switch continues answering for the virtual gateway after losing its only upstream path; this control addresses a different failure condition.

Question 246

A Nexus, UCS or MDS operations team encounters this issue: A data center team modifies a static service profile on every blade individually, causing configuration drift when a shared SAN policy changes. Which root cause best explains this behavior?

  1. The platform deployment assumes a management mode inconsistent with the intended UCS X-Series architecture.
  2. The configuration process bypasses the intended reusable UCS service profile template inheritance model.
  3. The VLAN is absent from the approved UCS LAN uplink connectivity or external switch trunk policy.
  4. The server pool qualification policy does not limit placement to servers with the required hardware capabilities.

Explanation

Correct Answer

B:

The technical cause is The configuration process bypasses the intended reusable UCS service profile template inheritance model. The appropriate response is: Use an approved updating service profile template and apply governed changes to its associated server profiles. Confirm successful repair: All attached eligible blades receive consistent policy changes with documented exceptions and maintenance impact.

Incorrect Answers

A:

The platform deployment assumes a management mode inconsistent with the intended UCS X-Series architecture. “Use the supported UCS X-Series Intersight Managed Mode workflow and associate appropriate server profile policies” would address that alternative cause, not the condition in this question: the configuration process bypasses the intended reusable UCS service profile template inheritance model.

C:

“Permit the intended VLAN on the correct UCS fabric uplink and downstream network policies without broad wildcard access” responds to this separate finding: the VLAN is absent from the approved UCS LAN uplink connectivity or external switch trunk policy. This question instead needs “Use an approved updating service profile template and apply governed changes to its associated server profiles”, so the alternative does not meet the stated condition.

D:

The server pool qualification policy does not limit placement to servers with the required hardware capabilities. “Create the supported UCS server pool qualification and associate the workload profile with eligible members” applies to that separate problem. The observed case is a data center team modifies a static service profile on every blade individually, causing configuration drift when a shared SAN policy changes; choosing this alternative would address the wrong failure mode.

Question 247

During a Cisco data center readiness review, engineers observe: Voice-processing virtual machines on UCS blades traverse a shared adapter, but their traffic is treated as best effort because the UCS class settings do not match the approved policy. Which operational guardrail would prevent a similar outage?

  1. Update UCS server pool qualifications as new hardware revisions enter the chassis.
  2. Review template association and change propagation before broad UCS configuration updates.
  3. Test UCS QoS policies with the upstream switching trust boundary after adapter-policy changes.
  4. Inspect chassis IOM inventory and dual-fabric paths during blade server deployment.

Explanation

Correct Answer

C:

This safeguard addresses ucs lan qos class mapping: UCS system QoS class and vNIC network-control treatment are not aligned to the traffic priority requirements. The appropriate prevention is: Test UCS QoS policies with the upstream switching trust boundary after adapter-policy changes. Other subsystem controls would not address the specified recurring failure.

Incorrect Answers

A:

The server pool qualification policy does not limit placement to servers with the required hardware capabilities. “Update UCS server pool qualifications as new hardware revisions enter the chassis” would address that alternative cause, not the condition in this question: uCS system QoS class and vNIC network-control treatment are not aligned to the traffic priority requirements.

B:

“Review template association and change propagation before broad UCS configuration updates” responds to this separate finding: the configuration process bypasses the intended reusable UCS service profile template inheritance model. This question instead needs “Test UCS QoS policies with the upstream switching trust boundary after adapter-policy changes”, so the alternative does not meet the stated condition.

D:

The chassis fabric attachment and server adapter mapping have not been configured for both intended IOM paths. “Inspect chassis IOM inventory and dual-fabric paths during blade server deployment” applies to that separate problem. The observed case is voice-processing virtual machines on UCS blades traverse a shared adapter, but their traffic is treated as best effort because the UCS class settings do not match the approved policy; choosing this alternative would address the wrong failure mode.

Question 248

While checking a production data center change, the team finds: A running production blade is reassigned to a different UCS service profile without understanding reboot or identity-change consequences, interrupting applications. Which operational guardrail would prevent a similar outage?

  1. Schedule encrypted UCS configuration backups and perform periodic isolated restore tests.
  2. Review association change previews, reboot implications and backout steps before production reassignment.
  3. Include hardware sensors and fault trend alerts in the standard UCS server health baseline.
  4. Check local RAID configuration, disk health and boot target during UCS C-Series acceptance.

Explanation

Correct Answer

B:

This safeguard addresses ucs service profile association maintenance: The service profile reassociation workflow ignores its potential disruptive impact on server identities and boot settings. The appropriate prevention is: Review association change previews, reboot implications and backout steps before production reassignment. Other subsystem controls would not address the specified recurring failure.

Incorrect Answers

A:

The UCS domain disaster-recovery process lacks a tested full configuration backup and restoration workflow. “Schedule encrypted UCS configuration backups and perform periodic isolated restore tests” would address that alternative cause, not the condition in this question: the service profile reassociation workflow ignores its potential disruptive impact on server identities and boot settings.

C:

“Include hardware sensors and fault trend alerts in the standard UCS server health baseline” responds to this separate finding: the monitoring coverage does not include relevant server hardware health telemetry and Intersight fault history. This question instead needs “Review association change previews, reboot implications and backout steps before production reassignment”, so the alternative does not meet the stated condition.

D:

The server's local storage controller lacks the approved mirrored virtual drive configuration for the boot policy. “Check local RAID configuration, disk health and boot target during UCS C-Series acceptance” applies to that separate problem. The observed case is a running production blade is reassigned to a different UCS service profile without understanding reboot or identity-change consequences, interrupting applications; choosing this alternative would address the wrong failure mode.

Question 249

While checking a production data center change, the team finds: A packet-capture appliance shows no useful frames after a SPAN session was configured with the destination set to an ordinary forwarding interface. What technical condition most directly accounts for the failure?

  1. The SPAN session source and dedicated monitor destination roles were assigned incorrectly.
  2. The interface selector and policy-group to physical-domain binding do not deliver the intended EPG attachment.
  3. The monitoring design lacks continuous streaming telemetry and historical assurance correlation for transient events.
  4. Flow-export destination reachability or the configured source and monitoring VRF are incorrect.

Explanation

Correct Answer

A:

The technical cause is The SPAN session source and dedicated monitor destination roles were assigned incorrectly. The appropriate response is: Configure the authorized SPAN source and monitor-only destination and confirm the capture appliance connection. Confirm successful repair: The analyzer receives copied packets from the target flow without becoming part of normal switching paths.

Incorrect Answers

B:

The interface selector and policy-group to physical-domain binding do not deliver the intended EPG attachment. “Correct the supported ACI interface policy selector and physical domain association for the host-facing port” would address that alternative cause, not the condition in this question: the SPAN session source and dedicated monitor destination roles were assigned incorrectly.

C:

“Enable approved supported streaming telemetry and Nexus Dashboard assurance views for relevant fabric health metrics” responds to this separate finding: the monitoring design lacks continuous streaming telemetry and historical assurance correlation for transient events. This question instead needs “Configure the authorized SPAN source and monitor-only destination and confirm the capture appliance connection”, so the alternative does not meet the stated condition.

D:

Flow-export destination reachability or the configured source and monitoring VRF are incorrect. “Repair the approved flow exporter source, destination and transport route, and verify collector acceptance” applies to that separate problem. The observed case is a packet-capture appliance shows no useful frames after a SPAN session was configured with the destination set to an ordinary forwarding interface; choosing this alternative would address the wrong failure mode.

Question 250

A data center implementation team investigates the following fault: Two Nexus switches form a vPC pair, but a VLAN needed by a downstream dual-homed host is missing from the peer-link allowed list. Which test outcome proves the intended service was restored?

  1. The analyzer receives copied packets from the target flow without becoming part of normal switching paths.
  2. Both intended interfaces are bundled and load-balanced without individual or suspended member state.
  3. The host VLAN remains reachable through either peer after a simulated downstream member failure.
  4. The designated aggregation switch is the root and the expected alternate links remain loop-free.

Explanation

Correct Answer

C:

This observation validates vpc peer link consistency: The vPC peer-link VLAN membership is inconsistent with downstream vPC service VLAN requirements. The corresponding corrective action is: Add the authorized VLAN to the peer-link trunk and resolve the corresponding vPC consistency alarms. Evidence about a different component does not establish the requested service outcome.

Incorrect Answers

A:

The SPAN session source and dedicated monitor destination roles were assigned incorrectly. “Configure the authorized SPAN source and monitor-only destination and confirm the capture appliance connection” would address that alternative cause, not the condition in this question: the vPC peer-link VLAN membership is inconsistent with downstream vPC service VLAN requirements.

B:

“Configure a matching supported LACP mode and port-channel membership across the two endpoints” responds to this separate finding: the port-channel peers use incompatible LACP negotiation settings and cannot aggregate all intended members. This question instead needs “Add the authorized VLAN to the peer-link trunk and resolve the corresponding vPC consistency alarms”, so the alternative does not meet the stated condition.

D:

Bridge priority design does not select the intended distribution switches as the RSTP root and secondary root. “Set approved spanning-tree bridge priorities and validate the intended root and blocked-port topology” applies to that separate problem. The observed case is two Nexus switches form a vPC pair, but a VLAN needed by a downstream dual-homed host is missing from the peer-link allowed list; choosing this alternative would address the wrong failure mode.