mcAfee Secure Website
23

Cisco 350-601 Bundle

Exam Code: 350-601

Exam Name Implementing and Operating Cisco Data Center Core Technologies (DCCOR)

Certification Provider: Cisco

Corresponding Certifications: CCIE Data Center , CCNP Data Center

350-601 Training Materials $25.00

Reliable & Actual Study Materials for 350-601 Exam Success

The Latest 350-601 Exam Questions as Experienced in the Actual Test!

  • 24
    Questions & Answers

    350-601 Questions & Answers

    630 Questions & Answers

    Includes questions types found on actual exam such as drag and drop, simulation, type in, and fill in the blank.

  • 25
    350-601 Video Course

    350-601 Training Course

    143 Video Lectures

    Based on Real Life Scenarios which you will encounter in exam and learn by working with real equipment.

exam =32

Implementing and Operating Cisco Data Center Core Technologies (DCCOR) (350-601) Practice Tests

Guarantee

Satisfaction Guaranteed

Pass4sure has a remarkable Cisco Candidate Success record. We're confident of our products and provide no hassle product exchange. That's how confident we are!

99.3% Pass Rate
Total Cost: $164.98
Bundle Price: $139.98

Purchase Individually

  • exam =34
    Questions & Answers

    Questions & Answers

    630 Questions

    $124.99
    exam =35
  • exam =37
    350-601 Video Course

    Training Course

    143 Video Lectures

    $39.99

Cisco 350-601 Practice Test 2

Question 10

A newly commissioned network, compute or storage service reports: A fabric experiences transient packet drops but operations relies on a once-per-day manual counter snapshot and misses short-lived congestion spikes. What technical condition most directly accounts for the failure?

  1. The monitoring design lacks continuous streaming telemetry and historical assurance correlation for transient events.
  2. The SPAN session source and dedicated monitor destination roles were assigned incorrectly.
  3. Flow-export destination reachability or the configured source and monitoring VRF are incorrect.
  4. The tenant VLAN-to-VNI mappings do not identify the same approved layer-two segment across VTEPs.

Explanation

Correct Answer

A:

The technical cause is The monitoring design lacks continuous streaming telemetry and historical assurance correlation for transient events. The appropriate response is: Enable approved supported streaming telemetry and Nexus Dashboard assurance views for relevant fabric health metrics. Confirm successful repair: The time-series reports expose the loss interval and correlate it with the affected interfaces and fabric paths.

Incorrect Answers

B:

The SPAN session source and dedicated monitor destination roles were assigned incorrectly. “Configure the authorized SPAN source and monitor-only destination and confirm the capture appliance connection” would address that alternative cause, not the condition in this question: the monitoring design lacks continuous streaming telemetry and historical assurance correlation for transient events.

C:

“Repair the approved flow exporter source, destination and transport route, and verify collector acceptance” responds to this separate finding: flow-export destination reachability or the configured source and monitoring VRF are incorrect. This question instead needs “Enable approved supported streaming telemetry and Nexus Dashboard assurance views for relevant fabric health metrics”, so the alternative does not meet the stated condition.

D:

The tenant VLAN-to-VNI mappings do not identify the same approved layer-two segment across VTEPs. “Align the intended VLAN-to-VNI bindings and associated NVE membership on the participating leaves” applies to that separate problem. The observed case is a fabric experiences transient packet drops but operations relies on a once-per-day manual counter snapshot and misses short-lived congestion spikes; choosing this alternative would address the wrong failure mode.

Question 11

A data center administrator identifies the following risk: A rack server intended for local mirrored boot disks reports an absent boot volume after the storage controller was left with unconfigured physical drives. Which verification result most directly demonstrates successful repair?

  1. The hypervisor passes hardware virtualization checks and starts a test virtual machine successfully.
  2. Intersight records the hardware fault and resolution, while workload stability returns after repair.
  3. The server recognizes the protected boot volume and tolerates the documented single-disk test condition.
  4. The blade receives the intended policy identity after the controlled operation and applications recover as planned.

Explanation

Correct Answer

C:

This observation validates ucs c series virtual disk raid policy: The server's local storage controller lacks the approved mirrored virtual drive configuration for the boot policy. The corresponding corrective action is: Create and verify the supported redundant local virtual drive and align the BIOS boot entry to it. Evidence about a different component does not establish the requested service outcome.

Incorrect Answers

A:

The BIOS policy disables required CPU virtualization support expected by the approved hypervisor. “Enable the supported virtualization features using the appropriate UCS BIOS policy and validate a controlled reboot” would address that alternative cause, not the condition in this question: the server's local storage controller lacks the approved mirrored virtual drive configuration for the boot policy.

B:

“Enable supported hardware inventory and fault monitoring, then investigate the affected DIMM and operational trend” responds to this separate finding: the monitoring coverage does not include relevant server hardware health telemetry and Intersight fault history. This question instead needs “Create and verify the supported redundant local virtual drive and align the BIOS boot entry to it”, so the alternative does not meet the stated condition.

D:

The service profile reassociation workflow ignores its potential disruptive impact on server identities and boot settings. “Perform an approved service profile reassociation during maintenance with identity, boot and rollback checks” applies to that separate problem. The observed case is a rack server intended for local mirrored boot disks reports an absent boot volume after the storage controller was left with unconfigured physical drives; choosing this alternative would address the wrong failure mode.

Question 12

A data center implementation team investigates the following fault: A UCS domain authenticates administrators through a remote server, but a misconfigured AAA order locks out all operators during a network outage. Which root cause best explains this behavior?

  1. The UCS administrative role assignment grants privileges beyond the user's defined operational responsibilities.
  2. The management access policy lacks a tested protected local recovery identity for remote AAA outages.
  3. The UCS login realm and remote AAA fallback policy do not provide the documented secured recovery path.
  4. The Intersight role assignment is not scoped to the authorized organization and permitted resource actions.

Explanation

Correct Answer

C:

The technical cause is The UCS login realm and remote AAA fallback policy do not provide the documented secured recovery path. The appropriate response is: Correct the supported UCS authentication realm order and emergency access procedure under change control. Confirm successful repair: Authorized operators authenticate normally through remote AAA and recover access through the documented fallback during an outage.

Incorrect Answers

A:

The UCS administrative role assignment grants privileges beyond the user's defined operational responsibilities. “Assign a supported restricted UCS role and scope matching the storage administration tasks” would address that alternative cause, not the condition in this question: the UCS login realm and remote AAA fallback policy do not provide the documented secured recovery path.

B:

“Configure a secured local break-glass account using Cisco-supported AAA fallback settings and access restrictions” responds to this separate finding: the management access policy lacks a tested protected local recovery identity for remote AAA outages. This question instead needs “Correct the supported UCS authentication realm order and emergency access procedure under change control”, so the alternative does not meet the stated condition.

D:

The Intersight role assignment is not scoped to the authorized organization and permitted resource actions. “Apply the approved organization-scoped Intersight RBAC role for the automation identity” applies to that separate problem. The observed case is a UCS domain authenticates administrators through a remote server, but a misconfigured AAA order locks out all operators during a network outage; choosing this alternative would address the wrong failure mode.

Question 13

A data center administrator identifies the following risk: A critical database server uses a single-homed orphan port on one vPC peer and loses service during peer-link failure despite other paths remaining up. Which verification result most directly demonstrates successful repair?

  1. Interested ports retain multicast group membership and nonmembers do not receive unwanted replicated streams.
  2. The server remains reachable during documented peer and peer-link failure tests without unsafe duplicate forwarding.
  3. Both intended interfaces are bundled and load-balanced without individual or suspended member state.
  4. The designated aggregation switch is the root and the expected alternate links remain loop-free.

Explanation

Correct Answer

B:

This observation validates vpc orphan port convergence: The failure design does not account for orphan-port behavior and the chosen peer recovery semantics. The corresponding corrective action is: Review supported orphan-port handling and move or protect the workload on the planned resilient attachment. Evidence about a different component does not establish the requested service outcome.

Incorrect Answers

A:

The VLAN lacks a reachable supported multicast querier. “Provide a valid IGMP querier through the routed gateway or supported switching configuration” would address that alternative cause, not the condition in this question: the failure design does not account for orphan-port behavior and the chosen peer recovery semantics.

C:

“Configure a matching supported LACP mode and port-channel membership across the two endpoints” responds to this separate finding: the port-channel peers use incompatible LACP negotiation settings and cannot aggregate all intended members. This question instead needs “Review supported orphan-port handling and move or protect the workload on the planned resilient attachment”, so the alternative does not meet the stated condition.

D:

Bridge priority design does not select the intended distribution switches as the RSTP root and secondary root. “Set approved spanning-tree bridge priorities and validate the intended root and blocked-port topology” applies to that separate problem. The observed case is a critical database server uses a single-homed orphan port on one vPC peer and loses service during peer-link failure despite other paths remaining up; choosing this alternative would address the wrong failure mode.

Question 14

A newly commissioned network, compute or storage service reports: A new WWPN zone has been created in the MDS zoning database but the application host still cannot see its storage array because the zoneset was never activated. Which deployment safeguard most directly reduces this failure risk?

  1. Include FCNS database and target registration checks before troubleshooting zoning alone.
  2. Check active zoneset state and distribution after all SAN access change approvals.
  3. Verify pending and committed device alias state whenever server HBA identities change.
  4. Use standardized single-initiator zoning patterns in the SAN access request process.

Explanation

Correct Answer

B:

This safeguard addresses active fibre channel zoneset validation: An inactive zoning database edit does not change the effective active zoneset on the SAN fabric. The appropriate prevention is: Check active zoneset state and distribution after all SAN access change approvals. Other subsystem controls would not address the specified recurring failure.

Incorrect Answers

A:

The target's FCNS registration is absent or stale even though the initiator's local FLOGI succeeded. “Include FCNS database and target registration checks before troubleshooting zoning alone” would address that alternative cause, not the condition in this question: an inactive zoning database edit does not change the effective active zoneset on the SAN fabric.

C:

“Verify pending and committed device alias state whenever server HBA identities change” responds to this separate finding: device alias changes have not been committed and distributed through the supported fabric database workflow. This question instead needs “Check active zoneset state and distribution after all SAN access change approvals”, so the alternative does not meet the stated condition.

D:

The zone combines initiators beyond the least-privilege single-initiator zoning design. “Use standardized single-initiator zoning patterns in the SAN access request process” applies to that separate problem. The observed case is a new WWPN zone has been created in the MDS zoning database but the application host still cannot see its storage array because the zoneset was never activated; choosing this alternative would address the wrong failure mode.

Question 15

During a Cisco data center readiness review, engineers observe: Two ACI endpoint groups should communicate over a narrowly permitted database port, but the contract is attached in the wrong provider-consumer direction. Which operational guardrail would prevent a similar outage?

  1. Test both allowed and denied EPG flows after modifying any ACI contracts or filters.
  2. Test IPv6 first-hop security along with DHCP and ARP controls during access-switch turnup.
  3. Review uSeg classification stability during virtual machine moves and tag changes.
  4. Audit trusted DHCP-snooping interfaces and VLAN activation during access-layer changes.

Explanation

Correct Answer

A:

This safeguard addresses aci contract consumer provider policy: The contract association does not connect the intended consumer EPG with the approved provider EPG and allowed filter. The appropriate prevention is: Test both allowed and denied EPG flows after modifying any ACI contracts or filters. Other subsystem controls would not address the specified recurring failure.

Incorrect Answers

B:

The access ports lack the supported first-hop security policy needed to restrict untrusted IPv6 router advertisements. “Test IPv6 first-hop security along with DHCP and ARP controls during access-switch turnup” would address that alternative cause, not the condition in this question: the contract association does not connect the intended consumer EPG with the approved provider EPG and allowed filter.

C:

“Review uSeg classification stability during virtual machine moves and tag changes” responds to this separate finding: the intended microsegmentation EPG classification rules do not distinguish the workload identities. This question instead needs “Test both allowed and denied EPG flows after modifying any ACI contracts or filters”, so the alternative does not meet the stated condition.

D:

DHCP snooping trust is applied to an untrusted edge port and allows unauthorized DHCP server replies. “Audit trusted DHCP-snooping interfaces and VLAN activation during access-layer changes” applies to that separate problem. The observed case is two ACI endpoint groups should communicate over a narrowly permitted database port, but the contract is attached in the wrong provider-consumer direction; choosing this alternative would address the wrong failure mode.

Question 16

While checking a production data center change, the team finds: A UCS service profile requires a newer adapter firmware feature, but the applied host firmware package omits the compatible adapter release. After remediation, which acceptance result is most relevant?

  1. The replacement blade identifies the intended LUN and completes a controlled SAN boot.
  2. The intended firmware versions activate while the measured service interruption remains within the planned window.
  3. The recovered management domain contains consistent service profiles, pools and fabric policies after restoration.
  4. The adapter operates on the supported firmware set and the required host feature becomes available.

Explanation

Correct Answer

D:

This observation validates ucs firmware policy package compatibility: The effective UCS host firmware package is inconsistent with the server adapter feature prerequisites. The corresponding corrective action is: Select a compatible validated firmware package and update the affected server policy under change control. Evidence about a different component does not establish the requested service outcome.

Incorrect Answers

A:

The SAN boot policy refers to an unavailable storage target identity rather than the authorized active target. “Update the service profile boot policy to use the valid target WWPN and correct boot LUN parameters” would address that alternative cause, not the condition in this question: the effective UCS host firmware package is inconsistent with the server adapter feature prerequisites.

B:

“Follow a supported staged firmware activation sequence and use a maintenance plan with rollback criteria” responds to this separate finding: the upgrade schedule ignores disruptive firmware activation dependencies and data-path redundancy constraints. This question instead needs “Select a compatible validated firmware package and update the affected server policy under change control”, so the alternative does not meet the stated condition.

C:

The UCS domain disaster-recovery process lacks a tested full configuration backup and restoration workflow. “Create or restore an authorized UCS configuration backup and validate the documented recovery procedure” applies to that separate problem. The observed case is a UCS service profile requires a newer adapter firmware feature, but the applied host firmware package omits the compatible adapter release; choosing this alternative would address the wrong failure mode.

Question 17

A newly commissioned network, compute or storage service reports: A packet-capture appliance shows no useful frames after a SPAN session was configured with the destination set to an ordinary forwarding interface. Which implementation action should the engineer take first?

  1. Create and use a supported configuration checkpoint or approved rollback before editing the production policy.
  2. Repair the approved flow exporter source, destination and transport route, and verify collector acceptance.
  3. Enable approved supported streaming telemetry and Nexus Dashboard assurance views for relevant fabric health metrics.
  4. Configure the authorized SPAN source and monitor-only destination and confirm the capture appliance connection.

Explanation

Correct Answer

D:

The root problem is that The SPAN session source and dedicated monitor destination roles were assigned incorrectly. The selected change addresses it directly: Configure the authorized SPAN source and monitor-only destination and confirm the capture appliance connection. Verify the outcome: The analyzer receives copied packets from the target flow without becoming part of normal switching paths.

Incorrect Answers

A:

This action concerns nexus configuration checkpoint recovery, where The change process omitted a recoverable NX-OS configuration checkpoint and validation plan. The reported failure instead stems from The SPAN session source and dedicated monitor destination roles were assigned incorrectly.

B:

This action concerns netflow exporter reachability, where Flow-export destination reachability or the configured source and monitoring VRF are incorrect. The corrective response here is “Configure the authorized SPAN source and monitor-only destination and confirm the capture appliance connection”; this alternative does not provide that response.

C:

This action concerns nexus dashboard assurance and streaming telemetry, where The monitoring design lacks continuous streaming telemetry and historical assurance correlation for transient events. The stem reports a packet-capture appliance shows no useful frames after a SPAN session was configured with the destination set to an ordinary forwarding interface; this control addresses a different failure condition.

Question 18

A data center administrator identifies the following risk: An unauthorized Fibre Channel switch is connected to a production MDS ISL and attempts to join the fabric without meeting the planned trusted-switch membership. What ongoing validation should operations establish for this service?

  1. Maintain approved HBA identity records and update port security during controlled hardware replacement.
  2. Monitor MACsec security associations and key rotation without assuming link-up equals encryption.
  3. Review MDS command authorization and SAN change permissions separately from ordinary read access.
  4. Review fabric-binding membership with SAN topology changes and device replacement plans.

Explanation

Correct Answer

D:

This safeguard addresses mds fibre channel fabric binding: Fabric binding controls are absent or do not identify the trusted peer switch identities permitted on the ISL. The appropriate prevention is: Review fabric-binding membership with SAN topology changes and device replacement plans. Other subsystem controls would not address the specified recurring failure.

Incorrect Answers

A:

Fibre Channel port security does not restrict fabric logins to the designated authorized WWPN identities. “Maintain approved HBA identity records and update port security during controlled hardware replacement” would address that alternative cause, not the condition in this question: fabric binding controls are absent or do not identify the trusted peer switch identities permitted on the ISL.

B:

“Monitor MACsec security associations and key rotation without assuming link-up equals encryption” responds to this separate finding: link-layer encryption is not enabled or negotiated for the intended MACsec-protected connection. This question instead needs “Review fabric-binding membership with SAN topology changes and device replacement plans”, so the alternative does not meet the stated condition.

C:

The MDS AAA and RBAC permissions grant zoning mutation privileges beyond monitoring needs. “Review MDS command authorization and SAN change permissions separately from ordinary read access” applies to that separate problem. The observed case is an unauthorized Fibre Channel switch is connected to a production MDS ISL and attempts to join the fabric without meeting the planned trusted-switch membership; choosing this alternative would address the wrong failure mode.

Question 19

A data center implementation team investigates the following fault: A data center server finds its iSCSI target portal but cannot establish a usable storage session because its initiator CHAP secret differs from the target configuration. Which design or configuration error caused the described issue?

  1. The application storage requirements conflate NFS file-sharing semantics with iSCSI block-device presentation.
  2. The iSCSI initiator and storage target do not agree on the configured CHAP authentication credentials.
  3. The storage switch plan omits an EPLD package compatibility assessment for the target hardware and image.
  4. The NFS export access rules do not authorize the requesting client address or security identity.

Explanation

Correct Answer

B:

The technical cause is The iSCSI initiator and storage target do not agree on the configured CHAP authentication credentials. The appropriate response is: Update the approved initiator and target CHAP secret settings using the supported secure workflow. Confirm successful repair: The iSCSI login authenticates successfully and the host discovers its authorized block LUN.

Incorrect Answers

A:

The application storage requirements conflate NFS file-sharing semantics with iSCSI block-device presentation. “Select and provision the required supported iSCSI block LUN rather than treating an NFS export as a raw disk” would address that alternative cause, not the condition in this question: the iSCSI initiator and storage target do not agree on the configured CHAP authentication credentials.

C:

“Review the applicable MDS EPLD package and schedule the correct supported component update” responds to this separate finding: the storage switch plan omits an EPLD package compatibility assessment for the target hardware and image. This question instead needs “Update the approved initiator and target CHAP secret settings using the supported secure workflow”, so the alternative does not meet the stated condition.

D:

The NFS export access rules do not authorize the requesting client address or security identity. “Update the scoped NFS export policy to include only the approved new hypervisor client addresses” applies to that separate problem. The observed case is a data center server finds its iSCSI target portal but cannot establish a usable storage session because its initiator CHAP secret differs from the target configuration; choosing this alternative would address the wrong failure mode.

Question 20

During a Cisco data center readiness review, engineers observe: A UCS domain loses management when its primary fabric interconnect is rebooted even though the secondary interconnect is operational. Which approved technology action addresses this incident most directly?

  1. Restore the supported boot policy and required SAN adapter path in the correct boot-device order.
  2. Configure the approved CIMC out-of-band address, gateway and management VLAN from a secured administration network.
  3. Repair the UCS fabric-interconnect cluster and management redundancy configuration and validate supported failover.
  4. Correct the supported fabric-interconnect server-port and chassis connectivity assignments, then rediscover the chassis.

Explanation

Correct Answer

C:

The root problem is that The clustered fabric-interconnect pair is not configured or tested for the expected management failover behavior. The selected change addresses it directly: Repair the UCS fabric-interconnect cluster and management redundancy configuration and validate supported failover. Verify the outcome: The secondary fabric interconnect takes over management duties without losing the approved domain configuration.

Incorrect Answers

A:

This action concerns ucs c series boot policy device order, where The configured boot-device order does not select the intended SAN boot path before local storage. The reported failure instead stems from The clustered fabric-interconnect pair is not configured or tested for the expected management failover behavior.

B:

This action concerns ucs c series cimc management networking, where The CIMC management interface has incorrect IP addressing or missing management default gateway reachability. The corrective response here is “Repair the UCS fabric-interconnect cluster and management redundancy configuration and validate supported failover”; this alternative does not provide that response.

D:

This action concerns ucs blade chassis fabric discovery, where The chassis discovery path between the fabric interconnect and its I/O modules is absent or misconfigured. The stem reports a UCS domain loses management when its primary fabric interconnect is rebooted even though the secondary interconnect is operational; this control addresses a different failure condition.