Question 180
A data center administrator identifies the following risk: A newly installed blade chassis has power but its I/O modules and blades never appear under fabric-interconnect inventory after uplink cabling was changed. Which corrective change best resolves this problem?
Explanation
Correct Answer
The root problem is that The chassis discovery path between the fabric interconnect and its I/O modules is absent or misconfigured. The selected change addresses it directly: Correct the supported fabric-interconnect server-port and chassis connectivity assignments, then rediscover the chassis. Verify the outcome: Both intended fabric paths enumerate the chassis and associated blades under UCS management.
Incorrect Answers
This action concerns ucs disruptive firmware activation planning, where The upgrade schedule ignores disruptive firmware activation dependencies and data-path redundancy constraints. The reported failure instead stems from The chassis discovery path between the fabric interconnect and its I/O modules is absent or misconfigured.
This action concerns ucs fabric interconnect management failover, where The clustered fabric-interconnect pair is not configured or tested for the expected management failover behavior. The corrective response here is “Correct the supported fabric-interconnect server-port and chassis connectivity assignments, then rediscover the chassis”; this alternative does not provide that response.
This action concerns ucs c series boot policy device order, where The configured boot-device order does not select the intended SAN boot path before local storage. The stem reports a newly installed blade chassis has power but its I/O modules and blades never appear under fabric-interconnect inventory after uplink cabling was changed; this control addresses a different failure condition.