Question 290
During a technical peer-review of network behavior in the area of time service security and diagnosis, engineers report: One device has the correct time zone display but a clock that drifts several minutes. Select the action most specific to this finding.
Explanation
Correct Answer
Fix NTP/PTP clock synchronization rather than only the display zone. Time-zone formatting changes presentation, not the underlying clock reference.
Incorrect Answers
This alternative, Restrict NTP peers to authorized time servers with access policy, fits: Time synchronization packets arrive from an unapproved public host. The NTP trust boundary should prevent arbitrary sources from influencing clock integrity.
Inspect reachability and peer association before changing syslog filters belongs to a different case: An NTP peer is configured but device stratum and association state show it is not synchronized. A configured NTP server entry alone does not prove synchronized time.
Configure the supported boundary-clock role and time domain is designed for this other requirement: A PTP boundary clock must serve downstream endpoints while following an upstream grandmaster. PTP hierarchy and timing role determine how precise time is propagated.