mcAfee Secure Website
exam =5
exam =6

Exam Code: 300-515

Exam Name: Implementing Cisco Service Provider VPN Services (SPVI)

Certification Provider: Cisco

Corresponding Certification: CCNP Service Provider

Cisco 300-515 Questions & Answers

Reliable & Actual Study Materials for 300-515 Exam Success

162 Questions & Answers with Testing Engine

"300-515: Implementing Cisco Service Provider VPN Services (SPVI)" Testing Engine covers all the knowledge points of the real Cisco 300-515 exam.

The latest actual 300-515 Questions & Answers from Pass4sure. Everything you need to prepare and get best score at 300-515 exam easily and quickly.

exam =7
Guarantee

Satisfaction Guaranteed

Pass4sure has a remarkable Cisco Candidate Success record. We're confident of our products and provide no hassle product exchange. That's how confident we are!

99.3% Pass Rate
Was: $137.49
Now: $124.99

Cisco 300-515 Practice Test 23

Question 220

After a provisional corrective action, a separate reviewer must decide whether to accept the service. A multihomed service should use a standby PE but both sides forward on the CE port. Which acceptance finding would most strongly support a provisional closure WITHOUT implying a lab-validated fix?

  1. Ignore forwarding-mode and multihoming differences when deciding the expected packet path in the Dual-homing single-active scenario.
  2. Infer an end-to-end service from one local attachment-circuit counter in the Dual-homing single-active scenario.
  3. Treat a green physical-port state as proof of correct remote Ethernet service membership in the Dual-homing single-active scenario.
  4. The review records the following evidence: Compare configured redundancy mode and Ethernet segment state with observed forwarding. It also documents authorized paths and respects this constraint: Do not promise all-active convergence for a single-active design.

Explanation

Correct Answer

D:

Both relevant operational evidence and a bounded negative/authorization check are needed before acceptance. This is only a theoretical study acceptance lens, not a real device or user-network validation.

Incorrect Answers

A:

“Ignore forwarding-mode and multihoming differences when deciding the expected packet path in the Dual-homing single-active scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Compare configured redundancy mode and Ethernet segment state with observed forwarding. Do not promise all-active convergence for a single-active design.

B:

“Infer an end-to-end service from one local attachment-circuit counter in the Dual-homing single-active scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Compare configured redundancy mode and Ethernet segment state with observed forwarding. Do not promise all-active convergence for a single-active design.

C:

“Treat a green physical-port state as proof of correct remote Ethernet service membership in the Dual-homing single-active scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Compare configured redundancy mode and Ethernet segment state with observed forwarding. Do not promise all-active convergence for a single-active design.

Question 221

A customer raises an incident during a normal service window. An Ethernet service has correct port status but its CFM continuity check peers remain absent. Which existing operational evidence would be the MOST discriminating first inspection before any configuration change?

  1. For Ethernet CFM MEP mismatch, correlate maintenance domain, service association and MEP direction with CCM reception.
  2. Treat every Ethernet VPN service as a multipoint E-LAN regardless of its agreement in the Ethernet CFM MEP mismatch scenario.
  3. Ignore forwarding-mode and multihoming differences when deciding the expected packet path in the Ethernet CFM MEP mismatch scenario.
  4. Infer an end-to-end service from one local attachment-circuit counter in the Ethernet CFM MEP mismatch scenario.

Explanation

Correct Answer

A:

“For Ethernet CFM MEP mismatch, correlate maintenance domain, service association and MEP direction with CCM reception” directly tests the reported service boundary rather than inferring the result from an indirect indicator. Link light is insufficient evidence of end-to-end Ethernet service.

Incorrect Answers

B:

“Treat every Ethernet VPN service as a multipoint E-LAN regardless of its agreement in the Ethernet CFM MEP mismatch scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Correlate maintenance domain, service association and MEP direction with CCM reception. Link light is insufficient evidence of end-to-end Ethernet service.

C:

“Ignore forwarding-mode and multihoming differences when deciding the expected packet path in the Ethernet CFM MEP mismatch scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Correlate maintenance domain, service association and MEP direction with CCM reception. Link light is insufficient evidence of end-to-end Ethernet service.

D:

“Infer an end-to-end service from one local attachment-circuit counter in the Ethernet CFM MEP mismatch scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Correlate maintenance domain, service association and MEP direction with CCM reception. Link light is insufficient evidence of end-to-end Ethernet service.

Question 222

A reviewer receives an incomplete technical change record. An Ethernet service has correct port status but its CFM continuity check peers remain absent. Which interpretation best preserves the limits of the available evidence and the service boundary?

  1. Assume EVPN BGP route visibility guarantees the corresponding frame is forwarded correctly in the Ethernet CFM MEP mismatch scenario.
  2. Apply this case-specific technical limit: Link light is insufficient evidence of end-to-end Ethernet service.
  3. Treat a green physical-port state as proof of correct remote Ethernet service membership in the Ethernet CFM MEP mismatch scenario.
  4. Combine all customer attachment circuits into one bridge domain to restore traffic in the Ethernet CFM MEP mismatch scenario.

Explanation

Correct Answer

B:

“Apply this case-specific technical limit: Link light is insufficient evidence of end-to-end Ethernet service” directly tests the reported service boundary rather than inferring the result from an indirect indicator. Link light is insufficient evidence of end-to-end Ethernet service.

Incorrect Answers

A:

“Assume EVPN BGP route visibility guarantees the corresponding frame is forwarded correctly in the Ethernet CFM MEP mismatch scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Correlate maintenance domain, service association and MEP direction with CCM reception. Link light is insufficient evidence of end-to-end Ethernet service.

C:

“Treat a green physical-port state as proof of correct remote Ethernet service membership in the Ethernet CFM MEP mismatch scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Correlate maintenance domain, service association and MEP direction with CCM reception. Link light is insufficient evidence of end-to-end Ethernet service.

D:

“Combine all customer attachment circuits into one bridge domain to restore traffic in the Ethernet CFM MEP mismatch scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Correlate maintenance domain, service association and MEP direction with CCM reception. Link light is insufficient evidence of end-to-end Ethernet service.

Question 223

A colleague proposes closing the fault after one apparently healthy metric. An Ethernet service has correct port status but its CFM continuity check peers remain absent. Which missing proof makes an immediate 'resolved' declaration unjustified?

  1. Issue production CFM loopback or linktrace probes without change-control authorization in the Ethernet CFM MEP mismatch scenario.
  2. Treat every Ethernet VPN service as a multipoint E-LAN regardless of its agreement in the Ethernet CFM MEP mismatch scenario.
  3. Do not close yet; reconcile this case-specific evidence: Correlate maintenance domain, service association and MEP direction with CCM reception.
  4. Use generic switch behavior to predict all IOS XR Ethernet features without release review in the Ethernet CFM MEP mismatch scenario.

Explanation

Correct Answer

C:

“Do not close yet; reconcile this case-specific evidence: Correlate maintenance domain, service association and MEP direction with CCM reception” directly tests the reported service boundary rather than inferring the result from an indirect indicator. Link light is insufficient evidence of end-to-end Ethernet service.

Incorrect Answers

A:

“Issue production CFM loopback or linktrace probes without change-control authorization in the Ethernet CFM MEP mismatch scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Correlate maintenance domain, service association and MEP direction with CCM reception. Link light is insufficient evidence of end-to-end Ethernet service.

B:

“Treat every Ethernet VPN service as a multipoint E-LAN regardless of its agreement in the Ethernet CFM MEP mismatch scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Correlate maintenance domain, service association and MEP direction with CCM reception. Link light is insufficient evidence of end-to-end Ethernet service.

D:

“Use generic switch behavior to predict all IOS XR Ethernet features without release review in the Ethernet CFM MEP mismatch scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Correlate maintenance domain, service association and MEP direction with CCM reception. Link light is insufficient evidence of end-to-end Ethernet service.

Question 224

During a controlled handoff between provider operations teams. An Ethernet service has correct port status but its CFM continuity check peers remain absent. Which proposal follows conservative customer-isolation and change-control practice?

  1. Ignore forwarding-mode and multihoming differences when deciding the expected packet path in the Ethernet CFM MEP mismatch scenario.
  2. Infer an end-to-end service from one local attachment-circuit counter in the Ethernet CFM MEP mismatch scenario.
  3. Treat a green physical-port state as proof of correct remote Ethernet service membership in the Ethernet CFM MEP mismatch scenario.
  4. Document the topology, perform this read-only assessment: Correlate maintenance domain, service association and MEP direction with CCM reception. Observe the constraint: Link light is insufficient evidence of end-to-end Ethernet service.

Explanation

Correct Answer

D:

“Document the topology, perform this read-only assessment: Correlate maintenance domain, service association and MEP direction with CCM reception. Observe the constraint: Link light is insufficient evidence of end-to-end Ethernet service” directly tests the reported service boundary rather than inferring the result from an indirect indicator. Link light is insufficient evidence of end-to-end Ethernet service.

Incorrect Answers

A:

“Ignore forwarding-mode and multihoming differences when deciding the expected packet path in the Ethernet CFM MEP mismatch scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Correlate maintenance domain, service association and MEP direction with CCM reception. Link light is insufficient evidence of end-to-end Ethernet service.

B:

“Infer an end-to-end service from one local attachment-circuit counter in the Ethernet CFM MEP mismatch scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Correlate maintenance domain, service association and MEP direction with CCM reception. Link light is insufficient evidence of end-to-end Ethernet service.

C:

“Treat a green physical-port state as proof of correct remote Ethernet service membership in the Ethernet CFM MEP mismatch scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Correlate maintenance domain, service association and MEP direction with CCM reception. Link light is insufficient evidence of end-to-end Ethernet service.

Question 225

After a provisional corrective action, a separate reviewer must decide whether to accept the service. An Ethernet service has correct port status but its CFM continuity check peers remain absent. Which acceptance finding would most strongly support a provisional closure WITHOUT implying a lab-validated fix?

  1. The review records the following evidence: Correlate maintenance domain, service association and MEP direction with CCM reception. It also documents authorized paths and respects this constraint: Link light is insufficient evidence of end-to-end Ethernet service.
  2. Combine all customer attachment circuits into one bridge domain to restore traffic in the Ethernet CFM MEP mismatch scenario.
  3. Assume EVPN BGP route visibility guarantees the corresponding frame is forwarded correctly in the Ethernet CFM MEP mismatch scenario.
  4. Use generic switch behavior to predict all IOS XR Ethernet features without release review in the Ethernet CFM MEP mismatch scenario.

Explanation

Correct Answer

A:

Both relevant operational evidence and a bounded negative/authorization check are needed before acceptance. This is only a theoretical study acceptance lens, not a real device or user-network validation.

Incorrect Answers

B:

“Combine all customer attachment circuits into one bridge domain to restore traffic in the Ethernet CFM MEP mismatch scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Correlate maintenance domain, service association and MEP direction with CCM reception. Link light is insufficient evidence of end-to-end Ethernet service.

C:

“Assume EVPN BGP route visibility guarantees the corresponding frame is forwarded correctly in the Ethernet CFM MEP mismatch scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Correlate maintenance domain, service association and MEP direction with CCM reception. Link light is insufficient evidence of end-to-end Ethernet service.

D:

“Use generic switch behavior to predict all IOS XR Ethernet features without release review in the Ethernet CFM MEP mismatch scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Correlate maintenance domain, service association and MEP direction with CCM reception. Link light is insufficient evidence of end-to-end Ethernet service.

Question 226

A customer raises an incident during a normal service window. A CFM CCM defect appears only during provider maintenance despite unchanged bridge-domain membership. Which existing operational evidence would be the MOST discriminating first inspection before any configuration change?

  1. Assume EVPN BGP route visibility guarantees the corresponding frame is forwarded correctly in the CFM periodic defect scenario.
  2. For CFM periodic defect, observe received CCM defect history and maintenance group identity over time.
  3. Treat a green physical-port state as proof of correct remote Ethernet service membership in the CFM periodic defect scenario.
  4. Combine all customer attachment circuits into one bridge domain to restore traffic in the CFM periodic defect scenario.

Explanation

Correct Answer

B:

“For CFM periodic defect, observe received CCM defect history and maintenance group identity over time” directly tests the reported service boundary rather than inferring the result from an indirect indicator. Never clear monitoring blindly before collecting incident evidence.

Incorrect Answers

A:

“Assume EVPN BGP route visibility guarantees the corresponding frame is forwarded correctly in the CFM periodic defect scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Observe received CCM defect history and maintenance group identity over time. Never clear monitoring blindly before collecting incident evidence.

C:

“Treat a green physical-port state as proof of correct remote Ethernet service membership in the CFM periodic defect scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Observe received CCM defect history and maintenance group identity over time. Never clear monitoring blindly before collecting incident evidence.

D:

“Combine all customer attachment circuits into one bridge domain to restore traffic in the CFM periodic defect scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Observe received CCM defect history and maintenance group identity over time. Never clear monitoring blindly before collecting incident evidence.

Question 227

A reviewer receives an incomplete technical change record. A CFM CCM defect appears only during provider maintenance despite unchanged bridge-domain membership. Which interpretation best preserves the limits of the available evidence and the service boundary?

  1. Issue production CFM loopback or linktrace probes without change-control authorization in the CFM periodic defect scenario.
  2. Treat every Ethernet VPN service as a multipoint E-LAN regardless of its agreement in the CFM periodic defect scenario.
  3. Apply this case-specific technical limit: Never clear monitoring blindly before collecting incident evidence.
  4. Use generic switch behavior to predict all IOS XR Ethernet features without release review in the CFM periodic defect scenario.

Explanation

Correct Answer

C:

“Apply this case-specific technical limit: Never clear monitoring blindly before collecting incident evidence” directly tests the reported service boundary rather than inferring the result from an indirect indicator. Never clear monitoring blindly before collecting incident evidence.

Incorrect Answers

A:

“Issue production CFM loopback or linktrace probes without change-control authorization in the CFM periodic defect scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Observe received CCM defect history and maintenance group identity over time. Never clear monitoring blindly before collecting incident evidence.

B:

“Treat every Ethernet VPN service as a multipoint E-LAN regardless of its agreement in the CFM periodic defect scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Observe received CCM defect history and maintenance group identity over time. Never clear monitoring blindly before collecting incident evidence.

D:

“Use generic switch behavior to predict all IOS XR Ethernet features without release review in the CFM periodic defect scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Observe received CCM defect history and maintenance group identity over time. Never clear monitoring blindly before collecting incident evidence.

Question 228

A colleague proposes closing the fault after one apparently healthy metric. A CFM CCM defect appears only during provider maintenance despite unchanged bridge-domain membership. Which missing proof makes an immediate 'resolved' declaration unjustified?

  1. Ignore forwarding-mode and multihoming differences when deciding the expected packet path in the CFM periodic defect scenario.
  2. Infer an end-to-end service from one local attachment-circuit counter in the CFM periodic defect scenario.
  3. Treat a green physical-port state as proof of correct remote Ethernet service membership in the CFM periodic defect scenario.
  4. Do not close yet; reconcile this case-specific evidence: Observe received CCM defect history and maintenance group identity over time.

Explanation

Correct Answer

D:

“Do not close yet; reconcile this case-specific evidence: Observe received CCM defect history and maintenance group identity over time” directly tests the reported service boundary rather than inferring the result from an indirect indicator. Never clear monitoring blindly before collecting incident evidence.

Incorrect Answers

A:

“Ignore forwarding-mode and multihoming differences when deciding the expected packet path in the CFM periodic defect scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Observe received CCM defect history and maintenance group identity over time. Never clear monitoring blindly before collecting incident evidence.

B:

“Infer an end-to-end service from one local attachment-circuit counter in the CFM periodic defect scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Observe received CCM defect history and maintenance group identity over time. Never clear monitoring blindly before collecting incident evidence.

C:

“Treat a green physical-port state as proof of correct remote Ethernet service membership in the CFM periodic defect scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Observe received CCM defect history and maintenance group identity over time. Never clear monitoring blindly before collecting incident evidence.

Question 229

During a controlled handoff between provider operations teams. A CFM CCM defect appears only during provider maintenance despite unchanged bridge-domain membership. Which proposal follows conservative customer-isolation and change-control practice?

  1. Document the topology, perform this read-only assessment: Observe received CCM defect history and maintenance group identity over time. Observe the constraint: Never clear monitoring blindly before collecting incident evidence.
  2. Combine all customer attachment circuits into one bridge domain to restore traffic in the CFM periodic defect scenario.
  3. Assume EVPN BGP route visibility guarantees the corresponding frame is forwarded correctly in the CFM periodic defect scenario.
  4. Use generic switch behavior to predict all IOS XR Ethernet features without release review in the CFM periodic defect scenario.

Explanation

Correct Answer

A:

“Document the topology, perform this read-only assessment: Observe received CCM defect history and maintenance group identity over time. Observe the constraint: Never clear monitoring blindly before collecting incident evidence” directly tests the reported service boundary rather than inferring the result from an indirect indicator. Never clear monitoring blindly before collecting incident evidence.

Incorrect Answers

B:

“Combine all customer attachment circuits into one bridge domain to restore traffic in the CFM periodic defect scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Observe received CCM defect history and maintenance group identity over time. Never clear monitoring blindly before collecting incident evidence.

C:

“Assume EVPN BGP route visibility guarantees the corresponding frame is forwarded correctly in the CFM periodic defect scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Observe received CCM defect history and maintenance group identity over time. Never clear monitoring blindly before collecting incident evidence.

D:

“Use generic switch behavior to predict all IOS XR Ethernet features without release review in the CFM periodic defect scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Observe received CCM defect history and maintenance group identity over time. Never clear monitoring blindly before collecting incident evidence.

Question 230

After a provisional corrective action, a separate reviewer must decide whether to accept the service. A CFM CCM defect appears only during provider maintenance despite unchanged bridge-domain membership. Which acceptance finding would most strongly support a provisional closure WITHOUT implying a lab-validated fix?

  1. Ignore forwarding-mode and multihoming differences when deciding the expected packet path in the CFM periodic defect scenario.
  2. The review records the following evidence: Observe received CCM defect history and maintenance group identity over time. It also documents authorized paths and respects this constraint: Never clear monitoring blindly before collecting incident evidence.
  3. Issue production CFM loopback or linktrace probes without change-control authorization in the CFM periodic defect scenario.
  4. Treat every Ethernet VPN service as a multipoint E-LAN regardless of its agreement in the CFM periodic defect scenario.

Explanation

Correct Answer

B:

Both relevant operational evidence and a bounded negative/authorization check are needed before acceptance. This is only a theoretical study acceptance lens, not a real device or user-network validation.

Incorrect Answers

A:

“Ignore forwarding-mode and multihoming differences when deciding the expected packet path in the CFM periodic defect scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Observe received CCM defect history and maintenance group identity over time. Never clear monitoring blindly before collecting incident evidence.

C:

“Issue production CFM loopback or linktrace probes without change-control authorization in the CFM periodic defect scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Observe received CCM defect history and maintenance group identity over time. Never clear monitoring blindly before collecting incident evidence.

D:

“Treat every Ethernet VPN service as a multipoint E-LAN regardless of its agreement in the CFM periodic defect scenario” cannot establish the provider/customer boundary. Check the actual service ownership: Observe received CCM defect history and maintenance group identity over time. Never clear monitoring blindly before collecting incident evidence.

Implementing Cisco Service Provider VPN Services (SPVI) (300-515) Practice Tests